Zip 801912UK User manual

801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04 Page 1 of 28
ZIP HydroTap®G4
User Manual
Affix model number label
here
801912UK

Page 2 of 28 801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04
3. Table of contents
• Elite HydroTap
®
G4.................................... Page 2
• Classic HydroTap
®
G4............................... Page 4
• Arc and Cube HydroTap
®
G4.................... Page 6
• All-in-One HydroTap
®
G4.......................... Page 9
• Classic, Arc and Cube mixer taps.......... Page 9
• LCD screen & menu................................. Page 10
• Filter maintenance ................................... Page 23
• Changing the CO2cylinder ..................... Page 25
• Home menu icons.................................... Page 27
• Cleaning.................................................... Page 28
• Contact details ......................................... Page 28
• Date of installation.........
Safety lock
Boiling
button
Chilled
button
Elite functionality
The Elite tap uses touch
sensitive controls to
dispense boiling, chilled
and sparkling water.
When operating the tap
ensure the touch surface
is dry as moisture may
interfere with the sensor touch
control.
The safety lock can be controlled
from either the tap or from the touch
screen display (See page 22).
Filter light
Boiling water
light
Sparkling buttons
(together)
Tap lights
Red BOILING water light
Continually illuminated
This indicates that the boiling water is ready.
Flashing slowly
This indicates that the boiling water is below the set dispense temperature.
Wait for the light to stop flashing before dispensing water. The light will
typically flash after switching on, or coming out of sleep mode.
Flashing quickly - warning light
When the indicator light flashes fast and continuous, a system fault has
occurred. Check for details on the faults screen (see page 12). If unable to
rectify, call a qualified service agent.
Elite HydroTap®G4

801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04 Page 3 of 28
Tap safety
The safety lock feature is provided to prevent boiling water flowing if the red
BOILING control is inadvertently activated.
This function can be activated and deactivated from either the tap or from the
White FILTER light
Filter light off
This indicates the filter is operating within its normal specified lifespan.
Filter light flashing slowly
The light will flash slowly when the filter is due for replacement and the LCD
will show ‘Filter Change. See ‘To change the filter’ page 23.
• To allow the safety setting to be changed using the touch screen, (see
page 22).
• To enable or disable the tap safety lock, (see page 22).
• For hot isolation, (see page 22).
To dispense boiling water with the safety lock off
Touching the red BOILING button allows the dispensing of boiling water.
To dispense boiling water with the safety lock on
Place a finger on the safety lock, then touch the red BOILING button,keeping
both fingers in position to dispense boiling water.
To dispense chilled water
Touch the blue CHILLED button to dispense chilled water.
touch screen display (located on the Command-CentreTM).
To activate the safety lock from the tap
(Ensure ‘Allow safety settings change’ is selected, see page 22).
First place a finger over the safety lock, then touch the CHILLED button, keep
both fingers in position for a period of approximately ten seconds.
To deactivate the safety lock from the tap
First place a finger over the safety lock, then touch the CHILLED button while
keeping both fingers in position for a period of approximately ten seconds.
To dispense water
To dispense sparkling water
Touch the blue CHILLED button and red BOILING button together,
simultaneously to dispense sparkling water.
Elite HydroTap®G4

Page 4 of 28 801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04
3. Classic HydroTap®G4 (inc. All -in One)
Boiling lever Chilled lever
Red
lights
Blue
lights
Filter
light
Safety Lock
Sparkling levers
(together)
Classic functionality
The Classic tap uses lever switch
controls to operate the tap.
Lever controls can be pushed back
to dispense water manually, or pulled
forward to dispense water for a fixed
time period, (see page 23). Once pulled
forward, levers need to be manually
returned to the OFF position.
The safety lock can be
controlled from either the tap or
from the touch screen display
(See page 22).
Tap lights
Red BOILING water lights
Continually illuminated
This indicates that the boiling water is ready.
Flashing slowly
This indicates that the boiling water is below the set dispense temperature.
Wait for the light to stop flashing before dispensing water. The light will
typically flash after switching on, or coming out of sleep mode.
Flashing quickly - warning light
When the indicator light flashes quickly and continuously, a system fault has
occurred.
Check for details on the faults screen (see page 12). If unable to rectify, call a
qualified service agent.
White FILTER light
Filter light off
This indicates the filter is operating within its normal specified lifespan.
Blue CHILLED water lights
Continually illuminated
This indicates that the temperature of the chilled water is within the set
temperature range.
Flashing slowly
This indicates that the chilled water is not within the set temperature range.
When the chilled water is at the set temperature, the light will stop flashing.
This could take several minutes.
During heavy usage, the temperature can rise out of this range.

801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04 Page 5 of 28
3. Classic HydroTap®G4 (inc. All -in One)
Tap safety
The safety lock feature is provided to prevent boiling water flowing if the red
BOILING control is inadvertently activated.
This function can be activated and deactivated from either the tap or from the
touch screen display (located on the Command-CentreTM).
To activate the safety lock from the tap
(Ensure ‘Allow safety settings change’ is selected, see page 22).
First place a finger over the safety lock, then depress the blue CHILLED lever,
keep both fingers in position for a period of approximately ten seconds. The
safety lock indicator light will illuminate.
To deactivate the safety lock from the tap
First place a finger over the safety lock, then depress the blue CHILLED
lever, while keeping both fingers in position for a period of approximately ten
seconds. The safety lock indicator light will extinguish.
• To allow the safety setting to be changed using the touch screen, (see
page 22).
• To enable or disable the tap safety lock, (see page 22).
• For hot isolation, (see page 22).
To dispense boiling water with the safety lock off
Press the red BOILING lever to dispense boiling water.
Pulling forward the red BOILING lever allows the tap to operate in a “no-
touch” mode. Water will flow from between 5 and 15 seconds (this is user
adjustable, see page 23).
To reset, return the lever to the OFF position and repeat the step. (The lever
has to be manually returned to the OFF position).
To dispense water
To dispense boiling water with the safety lock on
Press the red BOILING lever, while simultaneously covering the safety lock
button with a second finger. These two actions need to occur within 2 seconds
to dispense boiling water.
Filter light flashing slowly
The light will flash slowly when the filter is due for replacement and the LCD
will show ‘Filter Change’. (See To change the filter, page 23).
To dispense chilled water
Press the blue CHILLED lever to dispense chilled water.
Pulling forward the blue CHILLED lever allows the tap to operate in a “no-
touch” mode. Water will flow from between 5 and 15 seconds (this is user
adjustable, see page 23).
To reset, return the lever to the OFF position and repeat the step. The lever
has to be manually returned to the OFF position.

Page 6 of 28 801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04
3. Classic HydroTap®G4 (inc. All -in One)
To dispense sparkling water
Press both blue CHILLED and red BOILING levers together, simultaneously to
dispense sparkling water.
Pulling forward the blue CHILLED and red BOILING levers together allows the
tap to operate in a “no-touch” mode. Water will flow from between 5 and 15
seconds (this is user adjustable, see page 23).
To reset, return the lever to the OFF position and repeat the step. The lever
has to be manually returned to the OFF position.
Pull both levers forward
Safety
sensor
• Shield the HydroTap®G4 from any
direct sunlight.
• With the Command-CentreTM in
normal operating mode and safety
lock enabled, turn the power off.
• Pull both tap levers to the forward
position.
• Turn the power on.
• The Command-CentreTM will calibrate
the safety switch.
• Return the levers to the neutral
position.
Safety sensor calibration
Light intensity varies from site to site, therefore it is recommended that a
recalibration be performed at the time of the installation.
All direct sunlight must be shaded from the HydroTap®G4, during the
calibration. This can be achieved by closing any nearby curtains, blinds, etc.
Arc and Cube HydroTap®G4
Indicator light
Select button
Safety button
Rotary
control
Arc / Cube functionality
On power up, wait 30secs. for the unit to
calibrate before selecting either the BOILING
red illuminated with safety, CHILLED
blue or SPARKLING white illuminated
water mode, by touching the select
button.
The Arc / Cube control may be rotated in a forward
or reverse direction to
dispense water.
The rotary control is spring loaded in the forward
direction and when released, will return to the OFF
position.
When rotated in the reverse direction the tap
operates in a POT FILL mode. Water will flow from
between 5 and 15 seconds (This is user adjustable,
see page 23). To reset, return the control to the
OFF position and repeat the step. The control has to be manually returned to

801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04 Page 7 of 28
Arc and Cube HydroTap®G4
the OFF position.
When unattended, the control light will automatically default to the CHILLED
(blue illuminated) mode after a short period.
Tap lights
Red BOILING water (safety, select and indicator) lights
Continually illuminated
This indicates that the boiling water is ready.
Flashing slowly
This indicates that the boiling water is below the set dispense temperature.
Wait for the light to stop flashing before dispensing water. The light will
typically flash after switching on, or coming out of sleep mode.
Flashing quickly - warning light
When the indicator light flashes quickly and continuously, a system fault has
occurred.
Check for details on the faults screen (see page 12). If unable to rectify, call a
qualified service agent.
Blue CHILLED water lights
(safety, select and indicator)
Continually illuminated
This indicates that the temperature of the chilled water is within the set
temperature range.
Filter lights
All three tap lights (Safety, Select and Indicator light) will flash white every
10 seconds, indicating a filter change is required.
Reset the filter light see page 14.
Flashing slowly
This indicates that the chilled water is not within the set temperature range.
When the chilled water is at the set temperature, the light will stop flashing.
This could take several minutes.
During heavy usage, the temperature can rise out of this range.

Page 8 of 28 801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04
To dispense boiling water with the safety lock on
Touch the select button until the indicator, select and safety buttons illuminate
red, then touch the safety button twice until the three red lights flash (the
lights will flash for approx. 2 seconds) if the tap control is not rotated, then
the select, safety and indicator lights will return to continually illuminated red
(and after a short period the select and indicator lights will return to continually
illuminated blue as a safety precaution).
Boiling water may be dispensed by rotating the control while the three red
illuminated lights are flashing.
While dispensing boiling water, all three red illuminated lights will continue to
flash.
To dispense chilled water
Rotate the control when the indicator light is illuminated blue to dispense
chilled water.
If illuminated red or white, touch the SELECT button until the indicator light
illuminates blue.
To dispense sparkling water
Rotate the control when the indicator light is illuminated white to dispense
sparkling water.
If illuminated red, or blue touch the SELECT button until the indicator light
illuminates white.
Arc and Cube HydroTap®G4
To dispense water
To dispense boiling water with the safety lock off
Touch the SELECT button until the indicator and select lights illuminate red.
Rotate the control when the indicator lights are illuminated red to dispense
boiling water.

801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04 Page 9 of 28
All-in One HydroTap®G4
Tap functionality and
operation
The top of the All-in-
One tap is operated in
the same manner as a
Classic HydroTap®G4. The
two levers are used for
dispensing boiling, chilled
and sparkling water. The
safety lock also operating
in the same manner as the
Classic HydroTap®G4.
The mixer tap lever is
operated as a conventional
‘flick mixer’. The hot direction
is marked with a red dot and
the cold direction with a blue dot, for dispensing cold to warm water.
Moving the lever away from the tap will increase the flow rate and towards
the tap will decrease the flow rate.
When the lever is moved in the direction of the blue dot, the temperature is
decreased and when moved in the direction of the red dot, the temperature
is increased. The final temperature will be dependant on the temperature
of the incoming cold water. The spout may be swivelled, left or right, for
convenience.
Classic , Arc and Cube mixer taps
Tap functionality and operation
Classic, Arc and Cube mixer taps operate in the same manner as the All in One mixer
tap, detailed above.

Page 10 of 28 801912UK - Commercial Boiling, chilled and sparkling user manual - Sept 2016- v2.04
Zip HydroTap®G4 features a ‘TOUCH’ screen for easy setup and operation
adjustment.
(See page 27 for home menu icons).
Other possible messages in status window:
Status** Information Notes
Safety OFF Product is in normal operation
mode
-
Safety ON Safety lock is activated Refer to section
G - safety
System Fault Product has one or more system
faults
Refer to section B
- System info.
Sleep Mode System is in sleep mode. Boiling
water or hot water is not available.
Refer to section
G - Energy modes
Change Filter External/Internal filter needs to be
replaced
Refer to section C
- Installation
System Off System off in off mode. No boiling
water or chilled water available.
Refer to section
G - Energy modes
Hot Isolated Hot isolation has been activated.
Boiling water or hot water is not
available.
Refer to section
G - Safety
3LCD Screen
Note When selecting new options, the screen will revert to the main menu, if
the screen remains inactive for a period in excess of 10 seconds.
Note As an energy saving feature, the home screen will turn off after 5
minutes of non use. Touching the darkened LCD panel will reactivate the
home screen.
This manual suits for next models
1
Table of contents
Other Zip Water Dispenser manuals

Zip
Zip HC03CTU15 Manual

Zip
Zip HydroChill HCF090 Manual

Zip
Zip HYDROCHILL HC20 Series Manual

Zip
Zip HydroTap G4 Boiling, chilled sparkling... User manual

Zip
Zip Micro BC Manual

Zip
Zip HydroTap G4 Series User manual

Zip
Zip ZT400 Parts list manual

Zip
Zip HydroTap BCS160 User manual

Zip
Zip HydroTap G4 User manual

Zip
Zip Hydroboil Duo 310111 Manual