INTRODUCTION
Access Control Keypad with Waterproof
www.yli.cn We create security
Model:YK-668
YK-668 is the newest keypad for single door,there are 4 operation mode .Keyboard of YK-668
is made by mobile technology, with blue backlit and colorneverfade .Program of YK-668 is
produced by the newest MCU.
FEATURE
2000 pcs IC Card Capacity
Read Card and Register Card Continuously, Submit Card No. and Card Code Automatically
Read Card to Open and Close
Door Opening Signal Output by Relay Directly(NO/NC optional)
Operation Mode: Card, Code, Card or Code, Card +Code
SPECIFICATION
Size: 86x86x20(mm)
Operating Voltage: 12V 10%
Operating Current: <0.1A
Capacity of Recording: 2000 ID Cards and
1 Group Code
Operating Temperature: -10 50
Operating Humidity: 20%80%
Card Reading Distance: 5-15cm
Weight: 0.15kg
SOUND & LED INDICATION
Work State
Program Mode
Under Program Mode
Read Unregistered Card
Read Registered Card
Card or Code(Operation Mode)
EXPLANATION
Card +Code(Operation Mode)
Code(Operation Mode)
Press Keyboard
Setting Success
Setting Failure
Invalid Enter
Alarm
RED LED GREEN LED BUZZER
ON
ON
Twinkle
ON
DI(Long)
DI DI(Short)
DI(Short)
DI DI(Short)
DI(Long)
DI(Long)
DI DI DI...(repeatedly)
Twinkle 1 time
per 0.5 secretary
Twinkle 1 time
per 1 secretary
Red LED and Green LED
twinkle alternately
ON
P1

tested
Germany
EMC
R
OPERATION
www.yli.cn We create security
1.Enter Program Mode
Press # # # # (Red LED: Off, Green LED: On) 123456 # (If Success, Red LED: Off, Green
LED: Twinkle)
Remark: 123456 is the original Program Code
2.Modify Program Code
Press 0 New Program Code # New Program Code #
Remark: New Program Code must be 6 digits
3.Register Cards Continuously, Submit Card No. Automatically
Press 1 Read Card (Read Unregistered Card Continuously) #
Remark:
A: The system will keep record each card, then distribute Card NO. & Code (888888) automatically,
This Code (888888) is used in Card + Code Operation Mode condition, can't be use to open door sep-
arately." how to modify and use, will be explain in the following".
B: If there is no card record in system, means the first card NO. that user read is 0001, the second Numbe r
That user read is 0002, etc. But the max card NO .is not more than 2000.
C: If there are no card records, card NO. will be superimposed when read unregistered card. Such as,
the system keeps the record is 0260, and now, user read new unregistered card, the n this Card NO. is 0261.
D: If the Card (registered card) is exist, when user read it again, the buzzer will sound.
4.(1)Register 1 Card, Setting Card No. Manually
Remark:
A: If the Card (registered card) is exist, when user read it again, the buzzer will sound.
B: If the Code NO. is exist, when user enter it again, the buzzer will sound.
(2)Register Cards Continuously, Setting Card No. Manually
Register 1 Card, Setting Card No. Manually: Press 2 Read Card (Read 1 Unregistered Card)
+Card NO.(Setting by user)+ # #
Register Cards Continuously, Setting Card No. Manually: Press 2 ReadCard (Read Unregis-
tered Card) +Card NO. (Setti ng by user )+ # , Read Card (Read Unregistered Card) +CardNO.(Setting
by user)+ # ,...... #
5.Delete Card and Card Number
Delete Card: Press 30 Read Card # (User can delete Card Continuously)
Delete Card NO.: Press 31 Enter Card NO. + # # (User can delete Card NO. Continuously)
Delete Card NO.: Press 32 9999 # (User can delete all Cards and Card NO.)
6.Setting Operation Mode
1) Press 40 # (Card or Code Operation Mode, this is Default Setting when produce)
2) Press 41 # (Card + Code Operation Mode)
3) Press 42 # (Code Operation Mode)
7.Setting Time
Press 5 (time) #
For example:
Press 5 03 # , means the time setting is 3 sec
Press 5 22 # , means the time setting is 22 sec
Remark: Under can set 01-99 sec, the opening method of relay is touch (Read Card to Open, Read Card
to Close).
8.Setting Code (Default is blank when produce)
1) Press 6 New Code + # New Code+ # (Code is 4--6 digits)
2) Press 6 # # (User can't use code to open the door) P2

tested
Germany
EMC
R
OPERATION
www.yli.cn We create security
1.Read Card but can't open the door
A: Read Card with sound, but Green LED is OFF, please check the card is registered or not/
B: Read Card with sound, but Red LED and Green LED twinkle alternately, please check the Operation Mode
C: Read Card with sound and the Greed LED is ON, please check the wire connection is ok or not.
2. Read Card but no reaction
A: Check the card is ID or not, or the card is broken
B: Check the Operation Mode, Code Mode maybe shield the Card Function
C: Check the LED indication, Red LED is OFF, Green LED is ON, means the door is opening state
3. Press Keyboard but no reaction
Check the LED indication, Red LED is OFF, Green LED is ON, means the door is opening state
4. Buzzer is sound all the time
Check the anti-vandal switch is closed or not
9.ESC
Press *
10. Modify the Code of Card (Setting under the Card + Code Operation Mode)
Press (Green LED: ON) Read the card (This card is registered card) Enter the Old Code
*
(Red LED and Green LED: twinkle alternately) Enter the New Code # Enter theNewCode
again # (Green LED: OFF; Buzzer: DI DI)
Remark: If failure, the Buzzer will sound DI (long)
Returning to Factory Default (Only returnthe ProgramCode and System Parameter,Card can'tDeleted)
Cut off power (electricity) put the jumper JP1 in 2-3 position connect the power(DI DI<short>)
Put the Jumper JP1 in 1-2 position
MALFUNCTION JUDGMENT
WIRE INTRODUCTION
7 Wires (Main Port)
RED
BLACK
YELLOW
WHITE
BLUE
GREEN
GREEN
+12V
GND
NC
COM
NO
OPEN
GND
5 Wires (Card Reader Port)
RED
BLACK
GREEN
WHITE
BLUE
+12V
GND
D 0
D 1
LED BUZZER
P3
Table of contents