Yeastar S412 Installation Guide
2/12
Content
CONTENT....................................................................................................................................................................... 2
WELCOME ..................................................................................................................................................................... 3
BEFORE YOU START........................................................................................................................................................ 4
Package Contents ............................................................................................................................................4
Hardware Overview ..........................................................................................................................................4
LED Indicators and Ports..................................................................................................................................5
INSTALLATION................................................................................................................................................................ 7
Safety Disclaimers and Installation Warnings...................................................................................................7
Module Installation ............................................................................................................................................7
Desktop Installation ........................................................................................................................................10
CONNECTING THE EQUIPMENT.................................................................................................................................... 11
GETTING STARTED WITH THE CONFIGURATION ........................................................................................................... 12

Yeastar S412 Installation Guide
3/12
Welcome
Thank you for choosing Yeastar S412 IP PBX. Yeastar S412 is a stand-alone telephone system
offering an unrivalled range of features to small business. It supports various combinations of
telephony ports including FXS, PSTN, ISDN BRI, and GSM/3G/4G.
This guide describes how to install the S412 and how to log in the web GUI to configure the system.
Once you complete the installation, refer to the Yeastar S-Series Administrator Guide for instructions
on how to perform configurations on the system.
Related Documents
This Installation Guide only explains the installation of Yeastar S412 IPPBX. For more functionality
and advanced settings, please refer to the relative documents as below:
Document
Description
Yeastar S-Series Datasheet
Datasheet for the Yeastar S-Series IPPBX.
Yeastar S-Series Administrator Guide
The administrator could refer to this manual for
instructions on how to configure, operate, monitor,
and maintain the Yeastar S412 IPPBX.
Yeastar S-Series Extension User Guide
Users could refer to the guide for instructions on how
to login the user portal, and how to configure their
accounts, listen to call recordings, check voicemail
messages, etc.

Yeastar S412 Installation Guide
4/12
Before You Start
Before you begin to install the S412 IP Phone System, please check the package contents to verify
that you have received the items below. If there is any problem, please contact your provider.
Package Contents
1* S412 PBX
1* Power Adapter
1* Network Cable
4* Rubber Feet
1* Warranty Card
1* Quick Installation Guide
Hardware Overview
Front Panel
Power Indicator
FXS Status Line Status
System Status
WAN Status
LAN Status
Rear Panel
Line Port FXS Port Power Inlet
RESET
TF Card
LAN Port
WAN Port

Yeastar S412 Installation Guide
5/12
LED Indicators and Ports
LED Indicators
LED
Indication
Status
Description
POWER
Power status
On
The power is switched on
Off
The power is switched off
System
System status
Blinking
The system is running properly
Static/Off
The system goes wrong
WAN
WAN status
Static
Linked normally.
Blinking
In communication.
Off
Off-line.
LAN
LAN status
Static
Linked normally.
Blinking
In communication.
Off
Off-line.
FXS Port
Status
FXS
Green light
Static: The port is idle.
Blinking: There is an ongoing call on the
port.
Line Status
GSM/3G/4G
Red light
Static: the trunk is idle.
Blinking slowly: there is no SIM card
inserted.
Blinking rapidly: the trunk is in use.
BRI
Orange light
•Blinking slowly: the BRI line is
disconnected.
•Static: the BRI line is connected or in
use.
FXO
Red light
•Blinking slowly: no PSTN line is
connected
to the port.
•Static: the PSTN line is idle.
•Blinking rapidly: the PSTN line is busy.
Port Description
Ports
Description
Line Port
FXO port (red light): for the connection of PSTN lines or FXS ports of traditional
PBX.
BRI port (orange light): for the connection of ISDN BRI lines.
Note: the sequence number of the ports corresponds to that of the Indicator
lights in the front panel. (I.e. the LED lights in the front indicate the connection
status of the corresponding ports at the front panel.)
FXS Port
For the connection of analog phones
ANT
Rotate the antenna into the Antenna Socket.

Yeastar S412 Installation Guide
6/12
TF Slot
Insert TF card.
Ethernet Port
Yeastar S412 provides two 10/100M adaptive RJ45 Ethernet ports. There are 3
Ethernet modes for the system. The default mode is “Single”.
•Single: LAN port interface will be used for uplink connection. WAN port is
disabled.
•Bridge: LAN port interface will be used for uplink connection. WAN port
interface will be used as bridge for PC connection.
•Dual: both ports can be used for uplink connection.
Reset Button
Press and hold for 10 seconds to restore the factory defaults.
Power Inlet
Connect the supplied power supply to the port.

Yeastar S412 Installation Guide
7/12
Installation
This chapter shows you how to install Yeastar S412 IP phone system.
Safety Disclaimers and Installation Warnings
To avoid unexpected accident, personal injury or device damage, please read the safety disclaimers
and installation warnings.
Power
Use only the power adapter provided with the IP PBX.
Keep the power off during the installation.
Make sure that the supply voltage matches the specifications indicated on the back panel of the
device.
To avoid the electric accident, do not open or remove the cover of IP PBX when it is working as
well as off the power.
Before cleaning the device, cut off the power supply.
Environment
Install the Yeastar S412 IP PBX in a location that is clean, free from vibration, electric shock, and
temperature/humidity extremes. The operating temperature should be kept below 104°F (40°C).
Module Installation
Yeastar S412 is designed with 8 fixed on-board FXS ports and 4 reserved slots to insert
different modules according to your requirement. Yeastar S412 supports installing up to 2 modules.
The optional modules are as below:
•S2 Module
•O2 Module
•B2 Module
•GSM Module
•3G Module (WCDMA Module)
•4G Module (LTE Module)
Unpack S412, you can see the S412 main board as the following picture.
•T_Slot1: for S2 module only.
•T_Slot2: for S2 module only.
•T_Slot3: for O2 module, B2 module, GSM module, 3G module, 4G module.
•T_Slot4: for O2 module, B2 module, GSM module, 3G module.
NOTE
•Before installing the module, please check if the module is clean and intact.
•You need to install the 4G LTE module into T_Slot3 if you want to use 4G cellular network.

Yeastar S412 Installation Guide
8/12
STEP 1 Loosen the screws on the bottom of the device and remove the upper cover.
STEP 2 Insert the module to the Module Slot.
S412 Main Board

Yeastar S412 Installation Guide
9/12
STEP 3 Insert a SIM card on the GSM/3G/4G module following the instructions. Skip this step if no
GSM/3G/4G module installed.
STEP 4 Close the cover and fix the screws.
STEP 5 Rotate the antenna into the Antenna Socket. Skip this step if no GSM/3G/4G module
installed.

Yeastar S412 Installation Guide
10/12
Desktop Installation
WARNING
•Please set 5~10cm gaps around the device for air circulation.
•Please avoid any heavy thing placed on the device.
STEP 1 Place the IP PBX on a steady platform.
STEP 2 Remove the adhesive backing paper from the rubber feet.
STEP 3 Turn over the device and attach the supplied rubber feet to the recessed areas on the
bottom at each corner of the device.
Table of contents