WYLMAN PEGASUS User manual

FILLINGTHEGAPSINTECHNOLOGY
UserManual
PATENTPENDING
Dec2020
Rev.0

Table of Contents
1. WYLMAN PEGASUS 3
2. Safety Instructions 4
3. Compliance Statements 5
4. PEGASUS Overview 6-7
5. Included Accessories 8-10
6. Important Notes 11
7. Getting Started 12
7.1. Assigning PEGASUS Target 12-13
7.2. Activation 13-17
7.3. Deactivation 17-19
7.4. Activating/Updating PEGASUS Shield 19-21
8. Users 22
8.1. Users Privileges 22
8.2. Logging In 22-23
8.3. Changing Passwords 23-24
8.4. Resetting Passwords 24-25
9. Options 26
9.1. Session Settings 26
9.1.1. Session Time 26-27
9.1.2. Auto Logout and Shutdown 27
9.1.3. Session Invitations 27-29
9.1.4. Remote Access 29-30
9.1.5. IP Watchdog 30-31
9.1.6. Security 31-32
9.2. Network Settings 32
9.2.1. Network Adapters 32-34
9.2.2. Wi-Fi Access Points 34-36
9.3. PEGASUS Settings 36
User Manual 1
©2020 WYLMAN LLC. All Rights Reserved.

9.3.1. PEGASUS Password 36
9.3.2. Auto Updates 36-37
9.4. System Time 37-38
9.5. Shield Manager 38-39
9.6. License Manager 39-40
9.7. Check for Updates 40-43
10. Sessions 44
10.1. Connecting PEGASUS to Target Machine 44
10.2. Demo Sessions 44
10.3. Session Invitation 45-46
10.4. View Session 46-49
10.5. Control Session 49-52
11. Index 53
User Manual 2
©2020 WYLMAN LLC. All Rights Reserved.

1WYLMAN PEGASUS
PEGASUS is the most secure remote desktop setup and the only one that provides end to end remote desktop access
while effectively maintaining the air gapping of secured networks. It can be used in the most security sensitive systems.
Features:
1. Effectively maintains the air gapping of the remotely accessed computer
2. New approach achieving highest security
3. Easy User Interface
4. Can establish various types of connections with different privileges : Viewer, Controller
5. Doesn't require installation of any software to the accessed computer
For any questions please refer to https://wylman.com/contact
For any suggestions or for reporting technical issues contact [email protected]
User Manual 3
©2020 WYLMAN LLC. All Rights Reserved.

2Safety Instructions
Use the following safety guidelines to protect your PEGASUS from potential damage and to ensure your personal safety.
Unless otherwise noted, each procedure included in this document assumes that the following conditions exist:
You have read the safety information included.
A component and/or attachment can be removed by performing the installation procedure in reverse order.
If a third party attachment was used, you have read the safety instructions that came with it.
For best performance, only use the provided accessories and cables. Please contact us if cable(s) replacement or
cable(s) different length is/are needed.
Repairs may only be done by a certified service technician. End user should only perform troubleshooting and
simple accessory/cable replacement as authorized in this product documentation, or as directed by the online or
telephone service and support team. Damage due to servicing that is not authorized by WYLMAN is not covered
under warranty. Read and follow the safety instructions that came with the product.
Handle PEGASUS and accessories with care. Although PEGASUS enclosure is very rigid, strong impact from drops
can cause internal electronics to malfunction. Such damage will not be covered under warranty.
When disconnecting a cable, pull on its connector or on its pull-tab, not on the cable itself. As pulling connectors
apart, keep them evenly aligned to avoid bending any connector pins. Also, before connecting a cable, ensure that
both connectors are correctly oriented and aligned.
PEGASUS is secured with high security tamper proof screws, the screws must be checked for tampering marks
before every use. If any tampering marks are noticed, DO NOT use PEGASUS and contact WYLMAN for support.
WARNING: This product is designed to be used indoors and in non-hazardous areas. Do not use this product in a
hazardous classified areas as this may result in fires and/or explosions.
WARNING: To avoid damage to PEGASUS, use only the power supply provided. Do not use power supplies
designed for other devices.
User Manual 4
©2020 WYLMAN LLC. All Rights Reserved.

3 Compliance Statements
FCCComplianceStatement:
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
RoHSComplianceStatement:
All components and solder alloys used in this product comply with the RoHS Directive. The RoHS Directive prevents all
new electrical and electronic equipment placed on the market in the European Economic Area from containing more
than agreed levels of lead, cadmium, mercury, hexavalent chromium, poly-brominated biphenyls (PBB) and poly-
brominated diphenyl ethers (PBDE).
User Manual 5
©2020 WYLMAN LLC. All Rights Reserved.

4 PEGASUS Overview
1. Grounding Screw
It is recommended to connect the grounding screw to a clean/instrument ground bus.
2. 12VDC Power Input
Power input port; only user provided power supply.
3. Audio Output (3.5mm)
Optional audio output.
4. USB 2.0 Ports (x2)
Optional expansion USB ports, can be used to connect external network adapters, Keyboard, mouse, etc. It does not
support using any type of storage read and/or write devices; USB flash drive, external disc drive, etc.
5. Network Port (RJ45)
Optional wired network connection to connect to LAN and/or to the internet.
6. HDMI Output
Optional video output, can be used for PEGASUS configuration and/or monitoring.
User Manual 6
©2020 WYLMAN LLC. All Rights Reserved.

7. HDMI Input
Optional HDMI input, can be used to receive video signal from Target computer.
8. DVI Input
Optional DVI input/VGA input with the DVI-VGA adapter (included), can be used to receive video signal from Target
computer.
9. Keyboard & Mouse Port (Micro USB Type B)
Used to transfer the Keyboard & Mouse Commands from PEGASUS to Target Computer.
10. Power Switch
Used as the master on/off switch for PEGASUS.
User Manual 7
©2020 WYLMAN LLC. All Rights Reserved.

5 Included Accessories
1. Power Supply
UL certified AC (100-240VAC) to DC (12VDC 5A maximum) adapter.
It is strongly advised to only use the included power supply.
2. PEGASUS Shield
USB 2.0 8GB USB drive. Preloaded with PEGASUS Target ID software. Refer to "Activating/UpdatingPEGASUS
Shield(Section7.4)" section for details on loading the PEGASUS Shield software to the USB drive.
Please make sure that the included PEGASUS Shield USB drive is labeled with the same serial number as your
PEGASUS device. For security, these are the only USB drive that will work with your PEGASUS. Any other USB
drive will be detected as a security thread and PEGASUS will immediately shutdown.
Although PEGASUS Shield USB drive has much more capacity than needed for its function, it is strongly advised
to limit its use as intended in this manual.
3. HDMI Cable (6.6 ft)
High Speed HDMI Cable (30 AWG) Gold Plated with Ferrites (2M / 6.6 FT). This cable to be used to connect the Target
machine HDMI output to PEGASUS HDMI input.
Although any HDMI cable would work, it is strongly advised to use this cable to maintain the RFI under the FCC
legal limits. If your need different cable length please contact WYLMAN for support.
4. DVI-D Dual Link Video Cable (6.6 ft)
User Manual 8
©2020 WYLMAN LLC. All Rights Reserved.

DVI-D Dual Link DVI Cable with Ferrites (2M / 6.6 FT). This cable to be used to connect the Target machine DVI output
to PEGASUS DVI input.
Although any DVI cable would work, it is strongly advised to use this cable to maintain the RFI under the FCC
legal limits. If your need different cable length please contact WYLMAN for support.
5. SVGA Cable (6 ft)
SVGA Cable with Ferrites (1.8 M / 6 ft). This cable to be used to connect the Target machine DVI output to PEGASUS
DVI input (DVI to VGA adapter must be used, included).
Although any VGA cable would work, it is strongly advised to use this cable to maintain the RFI under the FCC
legal limits. If your need different cable length please contact WYLMAN for support.
6. USB 2.0 Cable (6.6 ft)
USB 2.0 cable A-MicroB male with ferrites (2M / 6.6 FT). This cable to be used to connect the PEGASUS Keyboard and
Mouse output to the Target machine.
User Manual 9
©2020 WYLMAN LLC. All Rights Reserved.
Other manuals for PEGASUS
1