WORMS Robin Subaru P 52 EX User manual

INSTRUCTIONS FOR USE
PUMP
MODEL
P 52 EX
FR
MU_P52EX_GB

2
Thank you for purchasing a Worms Entreprises pump set powered by ROBIN SUBARU.
This manual covers operation and maintenance of the pump set.
Please read this manual carefully.
For any further information please contact our after sales service at:
WORMS ENTREPRISES S.A.S.
Parc Gustav Eiffel
1 Bd. de Strasbourg
Bussy St Georges
77607 MARNE LA VALLEE-FRANCE
Tél. +33 (0) 1 64 76 29 50
Fax +33 (0) 1 64 76 29 88
In the case of a problem with your pump set, please note the engine serial number and use
it in any correspondence.
This pump is delivered without oil.

3
SUMMARY
1 - GENERAL PRESENTATION ........................................................ PAGE 4
2 - SAFETY INSTRUCTIONS .............................................................. PAGE 4
3 - SPECIFICATIONS .............................................................................. PAGE 6
4 - PREPARING THE PUMP FOR OPERATION .......................... PAGE 7
5 - PUMP SET USE .................................................................................. PAGE 9
6 - MAINTENANCE SCHEDULE ........................................................ PAGE 9
7 - MAINTENANCE GUIDE .................................................................. PAGE 11
8 - TROUBLESHOOTING ..................................................................... PAGE 12
9 - PREPARATION FOR STORAGE ................................................. PAGE 13
10 - SPARE PARTS ................................................................................. PAGE 14

4
1. GENERAL PRESENTATION
The unit is made up of the following:
- A clear or fresh water centrifugal pump set powered with a Robin Subaru gasoline
engine delivering 45 M3/h.
- The inlet and outlet ports are of a diameter of 2“ BSP, delivered with couplings and
strainer.
2. 2. SAFETY INSTRUCTIONS
Make sure that you review each warning and respect all safety recommendations.
2-1. ENVIRONMENT
Use your pump set on a flat, stable base, free from gravel or grit.
Install your pump set at least 1 meter from any building.
Install your pump set far away from any inflammable product (waste materiel, lubrication
liquid, explosive, …)
IN THE CASE OF FREEZING WEATHER CONDITIONS, MAKE SURE TO EMPTY
THE PUMP CASING TO AVOID BEING FROZEN AND DAMAGING THE PUMP.
2-2. FIRE PROTECTION
Stop the engine before filling the fuel tank.
Do not overfill the fuel tank and spill gasoline.
If the gasoline spills over, rapidly clean up the spilt gasoline and wait
for the traces to be dried up before restarting the engine.
Never use the pump set while smoking or near a naked flame.
2-3. EXHAUST GAS PROTECTION
Never breath in the exhaust gas: it contains carbon monoxide which
is odour and colourless and extremely dangerous for human health.
In extreme conditions it can be fatal.
Never use your pump set inside a building or in a closed environment.
Be extremely careful when using the pump set close to other people.

5
2-4. OTHER SAFETY PRECAUTIONS
Never get too close to moving parts or hot parts of the engine or
pump when it’s running.
Never let someone run the pump set without proper understanding
of the manual and safety instructions.
Start by familiarising yourself with emergency stopping procedure
as well as all aspects of safety controls to be made on the pump set
before starting the engine.
Correctly close the fuel tank cap before moving your pump set.
Check the engine oil level and top up if necessary before starting
the engine.
Check the fuel lines for fuel leaks before staring the engine.

6
3. SPECIFICATIONS
P 52 EX
Pump
Type of Pump Self priming
Suction Ø coupling 50 mm
Delivery Ø coupling 50 mm
Maximum flow 750 L/min - (45 m3/h)
Pressure 3,8 bars
Maximum total head 38 m
Maximum suction head 8 m
Solid size Ø -
Mechanical seal Carbone silicium
Engine
Engine Model EX 17
Engine Type 4 strokes gasoline
Fuel Unlead gasoline
Fuel tank capacity 3,6 Liters
Capacité du réservoir d’huile 0,9 Liters
Dimensions LxlxH (mm) 520 x 400 x 425
Dry weight 24 kg

7
4. PREPARING THE PUMP FOR OPERATION
4-1. CONNECT THE SUCTION PIPE TO THE PUMP
Use the appropriate tools to make the connection.
If the pump set is pumping water containing solids, ii is
necessary to use a strainer connected to the suction pipe.
These foreign bodies can damage the pump if they are sucked
into the pump casing.
4-2. CONNECTER THE DELIVERY HOSE TO THE PUMP
Use the appropriate tools to make the connection.
4-3. CHECK THE ENGINE OIL LEVEL
Place the pump set on a horizontal flat surface and fill the engine sump until you achieve
the maximum level on the dipstick (approximately 0,6 litre).
- Use an engine oil with a viscosity de 10 W 30 for ambient temperature between -15°C
to + 35°C
- If the conditions of use should exceed these limits, please contact WORMS
ENTREPRISES concerning the correct type of oil to use.
- Oil of an inferior quality or a lack of oil can cause serious engine damage and reduce
the expected engine life time.
Use only engine oil designed for petrol engines.
Never use engine oil designed for diesel engines.
To check the correct oil level, simply position the dipstick in the
tapped hole without screwing it into position.
4-4. FILLING THE ENGINE FUEL TANK
- Use unleaded automotive gasoline.
- The fuel should be new and free for foreign particles. The fuel should be transported
in containers designed for unleaded automotive gasoline. If this is not the case, the

8
carburettor could become faulty, blocked with foreign bodies.
- The tank contains 3,6 litres.
- Wipe off any spilt fuel thoroughly.
- Always stop the engine before refilling the fuel tank.
4-5. FILLING THE PUMP BODY WITH WATER
Fill the pump body with water through the fill plug located on the top of the casing, before
starting the engine.
Do not run the pump dry; always fill the pump body with water
before staring. Failing to do this will cause the pump to overheat.
Using the pump dry will destroy the mechanical shaft seal. If the
pump should run dry, the pump must be left to cool before filling
with water in order to avoid a thermal shock which will damage
the pump.

9
5. PUMP SET USE
5-1. STARTING
Place the engine speed control in the maximum position. Turn the engine switch to the on
position. Pull the recoil starter gently, when the effort increase due to the compression,
bring the recoil handle to its original position. Then pull the recoil starter swiftly to start
the engine, once the engine starts, return the handle slowly to its original position.
5-2. COLD STARTING
As described above, with the choke in the start position.
5-3. RUNNING SPEED
Once the engine started, open progressively the choke, place the engine speed control
in the minimum position and allow the pump to warm up for several minutes. Then
increase the speed to achieve the desired output. To save fuel and increase the pump
set life time, use the maximum engine speed only when necessary.
5-4. STOPPING THE ENGINE
Place the engine speed control lever in the minimum position and let the pump run
for several minutes. Then turn the engine switch to the stop position and wait until the
engine stops completely.
6. MAINTENANCE SCHEDULE
6-1. DAILY INSPECTION
Check the following points before using the pump set:
þFuel level in the tank
þAbnormal vibration or noise
þAbnormal exhaust gas (White, blue or black)
þClean air filter element
þSafe environment
þCorrect and clean oil level
þOil or fuel leaks
þBroken or missing nuts and bolts
þPump body filled with water

10
6-2. REGULAR INSPECTION
In order to maintain correct pump set performance it is necessary to follow the
recommended maintenance schedule as below.
The schedule is based on a regular use of your pump set.
This indicates that special tools or skills are required. Consult your local dealer.
Every : 8 hours
every day 100 h 300 h 500 h 1000 h
Check the fuel level þ
Check that all nuts and bolts are correctly
tightened þ
Check the engine oil þ Top up the level every day
Change the engine oil þ þ
Clean the air filter element þ
Open the pump body and clean the casing þ
Check the valve clearance
Clean the fuel strainer cup with unleaded
automotive gasoline(remove the foreign
bodies and water)
þ
Change the fuel strainer þ
Check the valve seats
Table of contents
Other WORMS Water Pump manuals
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual