Wonwoo Rapport 337 User manual

www.rapport337.com

Manufacturer : Wonwoo Engineering Co., Ltd.
www.rapport337.com Made in Korea
Distributed by:

T
T
ABLE OF CONTENTS
Before Reading the User's Manual 1
1. Safety Information 2
WARNING 2
2. Introduction of Rapport337 7
Names & Functions of Each Part 9
3. Specifications of Rapport337 14
General Specifications 14
Meter Specifications 15
4. Functional Use 17
Power ON/OFF 17
OSD Setup Screen when Power is on 17
Mode Setup 18
VIDEO TESTER 19
DIGITAL MULTI METER 22
PTZ CONTROLLER 29
UTP CABLE TESTER 34
VIEW INFORMATION 35
MAIN SETTING 35
www.rapport337.com

MEMO

B
B
ef or e Reading the User Õs Manual
W A R N I N G
Make sure to read through "Safety Information" before using
Rapport337.
This basic instruction manual is for users of Rapport337. Starting
with the outline of Rapport337, the manual is emphasized on the
explanations of its operation, how to be connected to the other
devices, how to use every button, and how to set up the system.
It is highly recommended, for those who have handled similar
devices as well as for those who are using it for the first time, to
read every description line by line, especially cautions, before using
the Rapport 337.
And when there is any question when in use or there is any
damage, make sure to contact the dealer of your Rapport337.
In the 1st Chapter "Safety Information" , warnings and
precautions are explained for the safety of users when Rapport337
is in use.
In the 2nd Chapter "Introduction of Rapport337" , its features
and appearance are explained.
In the 3rd Chapter "Specifications of Rapport337" , the
specification of the rapport337 components are explained.
In the 4th Chapter "Functional Use" , the functions of Rapport337
are explained so that the users can use it conveniently.
1
www.rapport337.com

1
1
. Saf ety Inf or mation
2
W A R N I N G
ඝThe following is important to use Rapport337 safely.
First of all, read through "the precautions for your safety " before
using the system.
Make sure to check the input and output range of voltage or current
at every input and output ports of Rapport337 before connecting
each of them, so that the system cannot be overloaded when in
use.
Set up the range for measuring voltage, current and resistance for
their known values and use the maximum range for unknown values
to protect the unit from damage.
www.rapport337.com

The following operational environment should be maintained
constantly for the proper use of Rapport337.
㯲
㯲
Temperature : -10 ~ 50
㯲Relative humidity : 30% ~ 90%
㯲Recharging voltage : 12V ·G10%, above 1A
1 . Saf ety Inf ormation
3
When the meter function is being used, do not connect any device
to the VIDEO IN/OUT terminals at that time, as the grounding could
cause any damage or trouble to both of them.
www.rapport337.com

4
W A R N I N G
ඝ
Pay attention to the following precautions when using
Rapport337.
Do not use the unit in damp humidity or leaking gas environments.
Do not touch it with wet hands.
Be mindful not to shock or shake the unit while in use to avoid
damage.
Avoid the places of strong magnetism or electric wave, which
would cause incorrect measuring.
Be careful not to expose the ports or joints to dirt or liquid.
Make sure to use specified replacement fuses described in the
3rd chapter.
Do not disassemble the Rapport 337.
Do not use the meter function, when the Rapport337 or the lead
set look damaged.
Do not measure resistance when the power is applied to a circuit.
When using the meter function, do not forget to turn on the power
of Rapport337 and set up the proper measurement mode before
connecting to a circuit to be measured.
Turn off the power to the circuit to be measured and discharge all
high voltage capacitance before starting resistance or continuity
tests to avoid damage to the Rapport 337.
Put the finger behind the protecting pad when using a probe.
www.rapport337.com

1 . Saf ety Inf ormation
5
W A R N I N G
ඝBattery Charging & Its Precautions
With the rechargeable 6 nickel hydrogen
(Ni-MH) AA-size batteries placed in,
Rapport337 can be charged with an
adopter of above DC 12V, 1A, and it
takes more than 8 hrs for the battery to
be fully charged.
The battery operates normally after initial
2 or 3 times of full charging, and it can be
used for about 3 hrs and above.
The battery charging can be checked on
the initial picture of POWER ON, and
also confirmed on the VIEW INFORMATION.
The battery is recharged when connected
to a DC adopter irrespective of the Power
slide S/W or button.
Alkaline battery(AA size) is usable for
about 2 hrs.
AUX
IN
DC12V
UTP
CABLE TEST
T R
DC12V, 1A
T R
www.rapport337.com

6
- Cautions for Battery -
The following batteries can be used for Rapport337
- (AA)-size alkaline battery (6EA)
- (AA)-size chargeable nickel hydrogen (Ni-MH) battery (6EA)
Use only chargeable nickel hydrogen (Ni-MH) batteries, when charging
batteries,using an adapter to Rapport337.
Place the CHARGE SWITCH "ON" position for recharging.
The CHARGE SWITCH is located on the upper part of battery insert.
(Refer to the figure below)
The performance of batteries can be very different, according to
manufacturers. Please use any reliable brand.
Do not mix batteries of different manufacturers when charging batteries.
Make sure not to disorient the polarization of batteries.
Do not short-circuit or disassemble batteries.
Make sure to check the polarization and the voltage and current
ratings before charging batteries and disconnect the charger
immediately should an abnormal situation arise.
www.rapport337.com
Table of contents
Popular Multimeter manuals by other brands

Gossen MetraWatt
Gossen MetraWatt METRAmax 6 operating instructions

PeakTech
PeakTech 4000 Procedure of calibration

YOKOGAWA
YOKOGAWA 90050B user manual

Gossen MetraWatt
Gossen MetraWatt METRALINE DMM16 operating instructions

Fluke
Fluke 8846A Programmer's manual

Tempo Communications
Tempo Communications MM200 instruction manual











