Wolf ICBWWD30O User manual

Warming Drawer Installation Guide

WARMING DRAWER
Contents
3Warming Drawer
4Specications
7Installation
7Troubleshooting
Features and specications are subject to change at any
time without notice. Visit wolfappliance.com/specs for the
most up-to-date information.
2
|
Wolf Customer Care 800.222.7820
Important Note
To ensure this product is installed and operated as safely
and efciently as possible, take note of the following types
of highlighted information throughout this guide:
IMPORTANT NOTE highlights information that is especially
important.
CAUTION indicates a situation where minor injury or product
damage may occur if instructions are not followed.
WARNING states a hazard that may cause serious injury or
death if precautions are not followed.
IMPORTANT NOTE: Throughout this guide, dimensions in
parentheses are millimeters unless otherwise specied.
IMPORTANT NOTE: Save these instructions for the local
electrical inspector.
SAVE THESE INSTRUCTIONS

wolfappliance.com
|
3
WARMING DRAWER
Product Information
Important product information including the model and
serial number are listed on the product rating plate. The
rating plate is located on the left front oor area of the inner
cabinet. The drawer must be open to view the rating plate.
Refer to the illustration below.
If service is necessary, contact Wolf factory certied service
with the model and serial number. For the name of the
nearest Wolf factory certied service or for questions
regarding the installation, visit the contact & support section
of our website, wolfappliance.com or call Wolf customer
care at 800-222-7820.
Rating plate location.
RATING
PLATE

4
|
Wolf Customer Care 800.222.7820
Installation Requirements
The warming drawer must be installed with a Wolf drawer
front, available through an authorized Wolf dealer. For local
dealer information, visit the nd a showroom section of our
website, wolfappliance.com. Specic installation instruc-
tions are included with the drawer front.
The warming drawer can be installed in a standard or ush
inset application (excludes L series drawer front).
Finish the edges of the opening. They may be visible when
the drawer is open.
For standard installations, face trim will overlap stiles and
rails. Refer to the chart below.
For ush inset installations, a minimum 1/8"(3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
An anti-tip block must be installed to prevent the warming
drawer from tipping forward when opened.
Model WWD30O is CSA approved for outdoor installations.
INSTALLATION REQUIREMENTS
BASE SUPPORT MIN
Warming Drawer 200 lb (90 kg)
TRIM OVERLAP
Top, Bottom and Sides 5/8"(16)
SPECIFICATIONS
Electrical
Installation must comply with all applicable electrical codes.
Locate the electrical supply ush with the back wall and
within the shaded area shown in the illustrations on the
following pages. For ease of installation, the electrical
supply for the warming drawer can be placed in an adjacent
cabinet within reach of the power cord.
IMPORTANT NOTE: When installed outdoors, a ground fault
circuit interrupter (GFCI) is required to reduce the risk of
electrical shock.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 120 VAC, 60 Hz
Service 15 amp dedicated circuit
Receptacle 3-prong grounding-type
Power Cord 3' (.9 m)
Rating plate location.
RATING
PLATE

wolfappliance.com
|
5
SPECIFICATIONS
Warming Drawer
STANDARD INSTALLATION
FRONT VIEW
SIDE
VIEW
TOP VIEW
NOTE: Location of electrical supply within opening may require additional cabinet depth.
23" (584)
OPENING
DEPTH
E
285/8" (727)
OPENING WIDTH
91/8" (232)
OPENING
HEIGHT
ANTI-TIP BLOCK

6
|
Wolf Customer Care 800.222.7820
SPECIFICATIONS
Warming Drawer
FLUSH INSET INSTALLATION
FRONT VIEW
SIDE
VIEW
TOP VIEW
*W
ill be visible and should be finished to match cabinetry.
**
Dimension provides minimum reveals.
NOTE: Location of electrical supply within opening may require additional cabinet depth.
24" (610)
FLUSH INSET
DEPTH
A
DRAWER
FRONT
DEPTH
105/8"
(270)
FLUSH INSET
HEIGHT**
301/8"(765)
FLUSH INSET WIDTH**
3/4"(19)
3/4"(19)
3/4"(19) E
E
FINISHED
CLEATS*
ANTI-TIP BLOCK
DRAWER FRONT DEPTH
M / E SERIES DRAWER FRONT A
Transitional / Professional 11/8"(29)
Professional (2" thick) 21/8"(54)
Contemporary 13/8"(35)
Custom front panel depth is dependent on panel thickness.

wolfappliance.com
|
7
Troubleshooting
IMPORTANT NOTE: If the warming drawer does not operate
properly, follow these troubleshooting steps:
•Verify electrical power is supplied to the warming drawer.
•Verify proper electrical connections.
•If the warming drawer does not operate properly, contact
Wolf factory certied service. Do not attempt to repair
the warming drawer. Wolf is not responsible for service
required to correct a faulty installation.
Wolf, Wolf & Design, Wolf Gourmet, W & Design and the color red as applied to knobs are registered trademarks and service marks of Wolf Appliance, Inc. Sub-Zero,
Sub-Zero & Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, and Ingredients are registered trademarks and service marks
of Sub-Zero, Inc. All other trademarks or registered trademarks are property of their respective owners in the United States and other countries.
Preparation
Remove and recycle packing materials. Do not discard the
package containing two screws provided for installation.
Install an anti-tip block against the rear cabinet wall. Verify
screws are adequately secured and do not penetrate elec-
trical wiring or plumbing.
Installation
1Turn power off to the electrical outlet.
2Slide the left corner of the warming drawer into the
opening. If the electrical supply is located in the opening,
plug the power cord into the receptacle. If it is located in
an adjacent cabinet, guide the power cord through the
hole in the cabinet wall. Coil excess power cord behind
or beside the unit.
3Slide the unit back into the opening until the trim
meets the cabinet front. Avoid pinching the power cord
between the unit and cabinet wall.
4Open the warming drawer to full extension. Drill a pilot
hole in each mounting hole, located at the front, on each
side of the unit. Refer to the illustration below.
5Mount the warming drawer using two screws provided.
6Turn power back on to the electrical outlet.
INSTALLATION
MOUNTING
HOLE
Mounting hole.

2
|
Atención al cliente de Wolf 800.222.7820
CAJÓN CALENTADOR
Contenido
3Cajón calentador
4Especicaciones
7Instalación
7Resolución de problemas
Las características y especicaciones están sujetas a
cambios sin previo aviso. Visite wolfappliance.com/specs
para obtener la información más actualizada.
Aviso importante
Para garantizar que este producto se instale y opere de
la forma más segura y eciente posible, tome nota de los
siguientes tipos de información resaltada en esta guía:
AVISO IMPORTANTE señala la información que es
especialmente importante.
PRECAUCIÓN indica una situación en la que se pueden
sufrir heridas leves o provocar daños al producto si no se
siguen las instrucciones.
ADVERTENCIA indica peligro de que se produzcan heridas
graves o incluso la muerte si no se siguen las precauciones.
AVISO IMPORTANTE: En toda esta guía, las dimensiones
entre paréntesis son milímetros, a menos que se especique
lo contrario.
AVISO IMPORTANTE: Guarde estas instrucciones para el
inspector eléctrico local.
GUARDE
ESTAS
INSTRUCCIONES

wolfappliance.com
|
3
CAJÓN CALENTADOR
Información del producto
La información importante del producto, incluido el modelo
y número de serie de la unidad, se encuentra en la placa
de datos del producto. La placa de datos se encuentra en
el área del piso frontal derecha del panel interno. El cajón
debe estar abierto para ver la placa de datos. Consulte la
siguiente ilustración.
Si necesita servicio, póngase en contacto con el centro de
servicio autorizado de Wolf y tenga a la mano el modelo y
número de serie de la unidad. Para obtener los datos del
centro de servicio autorizado de Wolf más cercano o si
tiene preguntas acerca de la instalación, visite la sección de
contacto y soporte técnico en nuestra página de Internet
wolfappliance.com o llame a la línea de atención al cliente
de Wolf al 800-222-7820.
Ubicación de la placa de datos.
PLACA DE
DATOS

4
|
Atención al cliente de Wolf 800.222.7820
Requisitos de instalación
El cajón calentador debe instalarse con una parte frontal
del cajón de Wolf, disponible a través de un distribuidor
autorizado de Wolf. Para obtener más información acerca
de los distribuidores locales, visite la sección para encontrar
una sala de exposición de nuestro sitio web, wolfappliance.
com. Con la parte frontal del cajón se incluyen las
instrucciones de instalación especícas.
El cajón calentador se puede instalar en una aplicación
estándar o empotrable (excepto una parte frontal del
cajón serie L).
Dé el acabado a los bordes de la abertura. Pueden ser
visibles cuando el cajón está abierto.
Para instalaciones estándares, el ribete frontal se
superpondrá a los largueros y las guías. Consulte la tabla
siguiente.
Para las instalaciones empotrables se requiere un margen
mínimo de 1/8"(3) en todos los lados. Para asegurar
márgenes consistentes, cada esquina de la abertura debe
tener exactamente 90º.
Se debe instalar un bloqueo antivuelco para evitar que el
cajón calentador se incline hacia delante al abrirlo.
El modelo WWD30O está aprobado por la Asociación
Canadiense de Normas (CSA, por sus siglas en inglés)
para instalaciones en exteriores.
REQUISITOS DE INSTALACIÓN
SOPORTE DE LA BASE MIN
Cajón calentador 200 lb (90 kg)
SUPERPOSICIÓN DEL RIBETE
Parte superior, parte inferior y costados 5/8"(16)
ESPECIFICACIONES
Instalación eléctrica
La instalación debe cumplir con todos los códigos
eléctricos vigentes.
Coloque el suministro eléctrico a ras con la pared posterior
y dentro del área sombreada que se muestra en las
ilustraciones de las páginas siguientes. Para facilitar la
instalación, el suministro eléctrico para el cajón calentador
se puede colocar en un gabinete adyacente al alcance del
cable de corriente.
AVISO IMPORTANTE: Cuando se instala al aire libre, es
necesario instalar un circuito de fallos de conexión a tierra
(GFCI, por sus siglas en inglés) para reducir el riesgo de
descarga eléctrica.
REQUISITOS ELÉCTRICOS
Suministro eléctrico Con conexión a tierra, 120 V CA, 60 Hz
Servicio Circuito dedicado de 15 amperes
Receptáculo Conexión a tierra de 3 clavijas
Cable de alimentación
eléctrica
3' (0.9 m)
Ubicación de la placa de datos.
PLACA DE
DATOS
This manual suits for next models
2
Table of contents
Languages:
Other Wolf Warming Drawer manuals

Wolf
Wolf WWDFRONT/B User manual

Wolf
Wolf ICBWWD30 Owner's manual

Wolf
Wolf WWD30 Owner's manual

Wolf
Wolf WWD30-2 User manual

Wolf
Wolf Warming Drawer User manual

Wolf
Wolf WWD30-2 Service manual

Wolf
Wolf MWD24-2 User manual

Wolf
Wolf WWD30 Instructions for use

Wolf
Wolf WWD30 User manual

Wolf
Wolf WARMING DRAWERS User manual































