4 | Wolf Customer Care 800.222.7820
Electrical Requirements
Installation must comply with all applicable electrical codes.
For ease of installation, the electrical supply for the oven
should be placed in an adjacent cabinet within reach of the
conduit.
Performance may be compromised if the electrical supply
is less than 240 volts.
The oven is supplied with a conduit consisting of two hot
lead conductors and a ground conductor. The wiring dia-
gram covering the control circuit is provided with the oven.
ELECTRICAL REQUIREMENTS
Electrical Supply grounded, 240/208 VAC, 60 Hz
Service 20 amp dedicated circuit
Conduit 4' (1.2 m)
Total Amps 16
Max Connected Load 3.6 kW
Specifications
Installation Requirements
The oven can be installed in a standard or flush inset
application.
Finish the edges of the opening. They may be visible when
the door is open.
For standard installations, the face trim overlaps stiles and
rails. Refer to the chart.
For flush inset installations, a minimum ⁄" (3) reveal is
required on all sides. To ensure consistent reveals, each
corner of the opening must be exactly 90°.
INSTALLATION REQUIREMENTS
Minimum Base Support 150 lb (68 kg)
TRIM OVERLAP
Top ⁄" (3)
Bottom 0" (0)
Sides ⁄" (22)
Rating plate location
RATING PLATE