Wisenet SWT-G0803MG Series User manual

QSG_SWT-G0803MG 08/12/2019 PAGE 1
QUICK START GUIDE SWT-G0803MG SERIES
QUICK START GUIDE
SWT-G0803MG Series
Environmentally Hardened Managed Ethernet Switch
3 SFP + 8 Electrical Ports with 60 Watt PoE
The SWT-G11MGHP is composed of the SWT-G0803MGPH240 Switch and PWR-
DR48480 Power Supply.
The switch has three 100/1000Base-FX SFP ports and eight 10/100/1000Base-TX
ports. The SFP ports support 2.5 Gbps SFPs for high-speed communication in
bandwidth-intensive applications. All SFP ports utilize SFP modules for fiber and
connector type and distance. The IEEE802.3-compliant unit offers multiple Ethernet
redundancy protocols (MSTP/RSTP/STP/ERPS (G.8032)) which protect your
applications from network interruptions or temporary malfunctions by redirecting
transmission within the network. The switch provides advanced IP-based
management that can limit the maximum bandwidth for each connected IP device,
allowing the user to adjust usage. The switch provides eight electrical ports supplying
Power over Ethernet (PoE). Four of the eight PoE ports can support up to 60 watts of
PoE power per port, while the other four ports support up to 30 watts of power per
port. All PoE ports are IEEE802.3af/IEEE802.3at compliant.
This guide serves the following
Model Names:
SWT-G0803MGHP240

QSG_SWT-G0803MG 08/12/2019 PAGE 2
QUICK START GUIDE SWT-G0803MG SERIES
Contents
Regulatory Compliance Statement 3
Warranty 3
Disclaimer 3
Safety Information 4
Hardware Installation 5
Installing the Switch on DIN-Rail 5
Wall Mounting Installation 7
Hardware Overview 8
9
9
Configuration by Web Browser
Setting an Initial Password
Using Switch CLI
Factory Default Procedure
9
Software Configuration 10
Power Supply
Front Panel LEDs
SWT-G0803MGHP240 60 W PoE Model
10
11
12
16

QSG_SWT-G0803MG 08/12/2019 PAGE 3
QUICK START GUIDE SWT-G0803MG SERIES
Regulatory Compliance Statement
Product(s) associated with this publication complies/comply with all applicable regulations. Please
refer to the Technical Specifications section for more details.
Warranty
Hanwha Techwin warrants that all products are free from defects in material and workmanship for
a specified warranty period of 3 years from the invoice date. Hanwha Techwin will repair or
replace products found by to be defective within this warranty period. Shipment expenses are to
be covered by the customer. This warranty does not cover product modifications or repairs done
by persons other than approved personnel, and this warranty does not apply to products that are
misused, abused, improperly installed, or damaged by accidents.
Disclaimer
Information in this publication is intended to be accurate. shall not be responsible for its use or
infringements on third-parties as a result of its use. There may occasionally be unintentional errors
on this publication. reserves the right to revise the contents of this publication without notice.

QSG_SWT-G0803MG 08/12/2019 PAGE 4
QUICK START GUIDE SWT-G0803MG SERIES
Safety Information
»Only service personnel can service the equipment. Please contact Technical Support.
»The equipment should be installed in locations with controlled access, or other means of
security, and controlled by persons of authority. When operating at temperatures above 51º C, the
equipment surfaces will be hot to the touch. Installation in restricted access location is required
for this case.
»For POE models requiring a power supply not labeled LPS, the unit should be installed in a
restricted access location using a 60950-1, 2nd Edition + Am. 1 + Am. 2 Certified power supply
rated for the ambient temperature in which it is installed. Total derated power rating should be
greater than the sum of the attached loads plus 15 W for the switch.
»Use CDRH compliant SFP modules when using fiber connectivity with this device.
»When used in Australia or New Zealand, the product is certified for intra building applications
only, and should not be directly connected to network cables with outside plant routing.

QSG_SWT-G0803MG 08/12/2019 PAGE 5
QUICK START GUIDE SWT-G0803MG SERIES
Hardware Installation
Installing the Switch on DIN-Rail
Each switch has a Din-Rail kit on the rear panel. The DIN-Rail kit affixes the switch to the DIN-Rail.

QSG_SWT-G0803MG 08/12/2019 PAGE 6
QUICK START GUIDE SWT-G0803MG SERIES
It is easy to install the switch on the Din-Rail:
Mount Series on DIN-Rail
Step 1: Tilt the switch and mount the metal spring to DIN-Rail.
Step 2: Push the switch toward the DIN-Rail until you hear the spring snap into place
.

QSG_SWT-G0803MG 08/12/2019 PAGE 7
QUICK START GUIDE SWT-G0803MG SERIES
Wall Mounting Installation
Each switch has another installation method for users to fix the switch. A wall mount panel can be
found in the package. The following steps show how to mount the switch on the wall:
Mounting the switch on a wall
Note: For drywall applications where no studs are available, use drywall anchors rated for 50 lbs
or more.
In order to prevent switches from being damaged, use appropriate hardware (not supplied)
for securing the unit to the wall.
#6 screws with at least ½-inch penetration into wood surface recommended.
Step 1: Remove DIN-Rail kit if it is installed.
Step 2: Remove the two screws at the top of the unit’s back panel. Remove only one pair of back
panel screws at time (these hold the back panel in place on the unit).
Step 3: Use the same two screws plus one of the included screws to attach the wall mount panel
to the top set of screw holes as shown in the diagram below.
Step 4: Repeat Steps 2 and 3 to mount the second wall mount panel on the bottom of the unit’s
back panel.
ATTENTION: Do not remove the top and bottom panel screws at the same time, or the back
panel will detach from the unit. Install the wall mount panels one at a time.
When operating at temperatures above 51ºC, the equipment surfaces will be
hot to the touch. Installation in restricted access location is required for this case.

QSG_SWT-G0803MG 08/12/2019 PAGE 8
QUICK START GUIDE SWT-G0803MG SERIES
Hardware Overview
2
1
2
8
3
5
7
4
6
SWT-G0803MGHP240
Call-out Description
13 × 100/1000/2500Base-FX SFP Ports
2
3
Link/Activity LED Indicators for SFP Ports
4
8 × 10/100/1000Base-TX RJ45 Ports
5
PoE LED Indicators
6
Alarm and Power LED Indicators
7
USB Console Port
8
Fault Relay 3-Pin Terminal Block Connector
Redundant Power 2-Pin Terminal Block Connectors

QSG_SWT-G0803MG 08/12/2019 PAGE 9
QUICK START GUIDE SWT-G0803MG SERIES
Power Supply
For SWT-G0803MGHP240 Model, Power Supply must be 44 to 57 VDC @ 255W max.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore,
consideration should be given to installing the equipment in an environment compatible with
the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air
flow required for safe operation of the equipment is not compromised.
Front Panel LEDs
LED Color Status Description
Alarm Red On Alarm Fault Status has been triggered
Power 1 Alarm Green On Power Input on VIN1 terminal block Input
Red On Power lost to VIN1 terminal block
Power 2 Alarm Green On Power Input on VIN1 terminal block Input
Red On Power lost to VIN2 terminal block
PoE (Power over Ethernet)
30W A Green On MODE A PoE is being supplied on indicated RJ-45 port
30W B Green On MODE B PoE is being supplied on indicated RJ-45 port
Gigabit Ethernet ports
Link Green On Port in Full Duplex mode
Activity Amber Blinking Data transmitted
Gigabit SFP ports
Link/Activity Amber Blinking Data transmitted
SWT-G0803MGHP24060W PoE Model
Port 1 to 4 support both mode A and mode B PoE which is 60 W in total. When a greater than 30
W PoE supported device is connected to ports 1 to 4, both 30 W A and B Indicator LEDs will be
turned on to indicate the high-power application device is connected.

QSG_SWT-G0803MG 08/12/2019 PAGE 10
QUICK START GUIDE SWT-G0803MG SERIES
Software Configuration
Attention: While installing and upgrading firmware, please remove physical loop connection first.
DO NOT power off equipment while the firmware is upgrading!
Configuration by Web Browser
About Web-based Management
An embedded HTML web site resides in the flash memory on the CPU board. It contains
advanced management features and allows you to manage the switch from anywhere on the
network through a standard web browser such as Microsoft Internet Explorer.
Preparing for Web Management
The default value is as below:
IP Address: 192.168.1.1
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.1.254
User Name: admin
Password: *Must be configured prior to login* Refer to p.11
System Login
1. Launch web browser.
2. Type ht t p://192 .168 .1.1. Press Enter.
3. The login screen appears.
4. Key in the username and password. The default username is admin. The password must have
been previously configured, otherwise access will be denied. Refer to p.11 to set an inital
password.
5. Select Enter or OK button, then the main interface of the Web-based management appears.
Warning – Any changes made to the settings will apply only to the current running
configuration of the switch and will be lost in the event of a power cycle.
To save any changes made to persistent memory please go to “Maintenance ¦
Configuration ¦ Save startup-config” to write the changes to the switches startup
configuration.
This manual suits for next models
3
Table of contents
Other Wisenet Switch manuals


















