WIKA TSD-30 User manual

EN
DE
FR
ES
Operating instructions
Betriebsanleitung
Mode d'emploi
Manual de instrucciones
Temperaturschalter Typ TSD-30
Temperature switch model TSD-30
Temperature switch model TSD-30
Thermostat type TSD-30
Termóstato modelo TSD-30

2WIKA operating instructions temperature switch model TSD-30
EN
DE
FR
ES
© 2011 WIKA Alexander Wiegand SE & Co. KG
All rights reserved. / Alle Rechte vorbehalten.
WIKA®is a registered trademark in various countries.
WIKA®ist eine geschützte Marke in verschiedenen Ländern.
Prior to starting any work, read the operating instructions!
Keep for later use!
Vor Beginn aller Arbeiten Betriebsanleitung lesen!
Zum späteren Gebrauch aufbewahren!
Lire le mode d‘emploi avant de commencer toute opération !
A conserver pour une utilisation ultérieure !
¡Leer el manual de instrucciones antes de comenzar cualquier trabajo!
¡Guardar el manual para una eventual consulta posterior!
Operating instructions model TSD-30 Page 3 - 30
Betriebsanleitung Typ TSD-30 Seite 31 - 58
Mode d‘emploi type TSD-30 Page 59 - 86
Manual de instrucciones modelo TSD-30 Página 87 - 115
11613025.04 05/2018 EN/DE/FR/ES

3WIKA operating instructions temperature switch, model TSD-30
EN
11613025.04 05/2018 EN/DE/FR/ES
Declarations of conformity can be found online at www.wika.com.
1. General information 4
2. Safety 6
3. Specications 9
4. Design and function 16
5. Transport, packaging and storage 17
6. Commissioning, operation 18
7. Maintenance and cleaning 27
8. Faults 28
9. Dismounting, return and disposal 30
Contents

4WIKA operating instructions temperature switch, model TSD-30
EN
11613025.04 05/2018 EN/DE/FR/ES
1. General information
■
The temperature switch described in the operating instructions has been designed and manufactured
using state-of-the-art technology. All components are subject to stringent quality and environ
mental
criteria during production. Our management systems are certied to ISO 9001 and ISO 14001.
■
These operating instructions contain important information on handling the instrument.Working safely
requires that all safety instructions and work instructions are observed.
■
Observe the relevant local accident prevention regulations and general safety regulations for the
instrument's range of use.
■
The operating instructions are part of the product and must be kept in the immediate vicinity of the
instrument and readily accessible to skilled personnel at any time.
■
Skilled personnel must have carefully read and understood the operating instructions prior to begin-
ning any work.
■
The manufacturer's liability is void in the case of any damage caused by using the product contrary to
its intended use, non-compliance with these operating instructions, assignment of insuciently quali-
ed skilled personnel or unauthorised modications to the instrument.
■
The general terms and conditions contained in the sales documentation shall apply.
■
Subject to technical modications.
■
Further information:
- Internet address: www.wika.de / www.wika.com
- Relevant data sheet: TE 67.03
- Application consultant: Tel.: +49 9372 132-8976
Fax: +49 9372 132-8008976
1. General information

5WIKA operating instructions temperature switch, model TSD-30
EN
11613025.04 05/2018 EN/DE/FR/ES
Explanation of symbols
WARNING!
... indicates a potentially dangerous situation that can result in serious injury or death, if not
avoided.
CAUTION!
... indicates a potentially dangerous situation that can result in light injuries or damage to
equipment or the environment, if not avoided.
Information
… points out useful tips, recommendations and information for ecient and trouble-free
operation.
CAUTION!
... indicates a potentially dangerous situation that can result in burns, caused by hot
surfaces or liquids, if not avoided.
Abbreviations
U+Positive power terminal
U-Reference potential
S+Analogue output
SP1 1 switch point
SP2 2 switch point
C Communication with IO-Link
MBA Start of measuring range
MBE End of measuring range
1. General information

6WIKA operating instructions temperature switch, model TSD-30
EN
11613025.04 05/2018 EN/DE/FR/ES
2. Safety
WARNING!
Before installation, commissioning and operation, ensure that the appropriate temperature
switch has been selected in terms of measuring range, design and specic measuring
conditions.
Non-observance can result in serious injury and/or damage to the equipment.
WARNING!
Observe the working conditions in accordance with chapter 3 „Specications”.
Further important safety instructions can be found in the individual chapters of these
operating instructions.
2.1 Intended use
The temperature switch is used to convert temperature into an electrical signal indoors and outdoors.
The instrument has been designed and built solely for the intended use described here, and may only
be used accordingly.
The technical specications contained in these operating instructions must be observed. Improper
handling or operation of the temperature switch outside of its technical specications requires the
instrument to be taken out of service immediately and inspected by an authorised WIKA service
engineer.
The manufacturer shall not be liable for claims of any type based on operation contrary to the intended use.
Use of accessories and spare parts
It is recommended to use original accessories and original spare parts from WIKA. Using accessories
and spare parts from third parties can lead to damage to the instrument or accidents, due to quality
defects or other reasons.WIKA assumes no liability for damage or accidents caused by a malfunction or
unsuitability of accessories and spare parts which do not originate from WIKA (e.g. non-compliance with
the IP ingress protection of connectors). No warranty claims can be made which arise due to a malfunc-
tion or unsuitability of any accessory or spare part from a third party.
2. Safety

7WIKA operating instructions temperature switch, model TSD-30
EN
11613025.04 05/2018 EN/DE/FR/ES
2.2 Personnelqualication
WARNING!
Riskofinjuryshouldqualicationbeinsucient!
Improper handling can result in considerable injury and damage to equipment.
The activities described in these operating instructions may only be carried out by skilled
personnel who have the qualications described below.
Skilled personnel
Skilled personnel are understood to be personnel who, based on their technical training, knowledge
of measurement and control technology and on their experience and knowledge of country-specic
regulations, current standards and directives, are capable of carrying out the work described and
independently recognising potential hazards.
Special operating conditions require further appropriate knowledge, e.g. of aggressive media.
2.3 Special hazards
WARNING!
For hazardous media such as oxygen, acetylene, ammable or toxic gases or liquids,
and refrigeration plants, compressors, etc., in addition to all standard regulations, the
appropriate existing codes or regulations must also be followed.
WARNING!
Residual media in the dismounted temperature switch can result in a risk to persons, the
environment and equipment.
Take sucient precautionary measures.
2. Safety

8WIKA operating instructions temperature switch, model TSD-30
EN
11613025.04 05/2018 EN/DE/FR/ES
2.4 Labelling, safety marks
Product label
2. Safety
IO-Link (option) Pin assignment and specications
Measuring range Coded date of production
P# Product No. Approvals
S# Serial No.
If the serial number becomes illegible (e.g. due to mechanical damage or overpainting), traceability will
no longer be possible.
Before mounting and commissioning the instrument, ensure you read the operating
instructions!
TSD-30
-20 ... +120 °C
P# 14266568
S# 110AKMAR
www.wika.com 8A
connection diagramm

9WIKA operating instructions temperature switch, model TSD-30
EN
11613025.04 05/2018 EN/DE/FR/ES
3.Specications
3. Specications
3.1 Measuring ranges
Temperature °C °F
Standard -20 ... +80 -4 ... +176
Option 1 1) 2) -20 ... +120 -4 ... +248
Option 2 1) 2) 0 ... 150 32 ... 302
1) Only for process connections with compression tting.
2) Installation instructions under “Operating conditions” must be observed.
3.2 Display
14-segment LED, red, 4-digit, 9 mm (0.35 in) character size
Display can be turned electronically through 180°
Update: 200 ms
3.3 Output signal
Switching output Analogue signal
SP1 SP2
PNP - 4 ... 20 mA (3-wire)
PNP - DC 0 ... 10 V (3-wire)
PNP PNP -
PNP PNP 4 ... 20 mA (3-wire)
PNP PNP DC 0 ... 10 V (3-wire)
Optionally also available with an NPN instead of a PNP switching output.

10 WIKA operating instructions temperature switch, model TSD-30
EN
11613025.04 05/2018 EN/DE/FR/ES
3.Specications
IO-Link, revision 1.1 (option)
IO-Link is optionally available for all output signals.
With the IO-Link option, switching output SP1 is always PNP
Switching thresholds
Switch point 1 and switch point 2 are individually adjustable
Switching functions
Normally open, normally closed, window, hysteresis freely adjustable
Switching voltage:
Power supply - 1 V
Switching current
■
without IO-Link: max. 250 mA
■
with IO-Link: SP1 max. 100 mA, SP2 max. 250 mA
Adjustment accuracy
≤ 0.5 % of span
Temperatureosetadjustment
±3 % of span
Scaling
Zero point: 0 ... 25 % of span
Full scale: 75 ... 100 % of span
Load
Analogue signal 4 ... 20 mA: ≤ 0.5 kΩ
Analogue signal DC 0 ... 10 V: > 10 kΩ
Service life
100 million switching cycles
Other manuals for TSD-30
1
Table of contents
Languages:
Other WIKA Switch manuals

WIKA
WIKA KSR HLS User manual

WIKA
WIKA PSA-31 User manual

WIKA
WIKA SERIES DW User manual

WIKA
WIKA Phase-Out PSD-3 Series User manual

WIKA
WIKA APW SERIES User manual

WIKA
WIKA EGS80 Series User manual

WIKA
WIKA PS-21 User manual

WIKA
WIKA TFS135 User manual

WIKA
WIKA TXS Series User manual

WIKA
WIKA PSD-4 User manual

WIKA
WIKA FSD-3 User manual

WIKA
WIKA TSD-30 User manual

WIKA
WIKA PSD-4 User manual

WIKA
WIKA KSR KUEBLER BGU D Series User manual

WIKA
WIKA OLS-C Series User manual

WIKA
WIKA DW03 Series User manual

WIKA
WIKA TFS135 User manual

WIKA
WIKA FSM-6100 User manual

WIKA
WIKA mw series User manual

WIKA
WIKA A2G-45 User manual





















