INSTRUCTIONS & SPARE PARTS CATALOGUE WP300_ ENG_1

2
Safety Instructions ..............................................................................3,4
Technical Data....................................................................................5
Pre-Operation Note.............................................................................6
Safety Precautions..............................................................................7,8
Setting up the WP300.........................................................................9
Pre-Operation Procedures .................................................................10,11
Operation Procedures.........................................................................12,13
Maintenance Procedures....................................................................14
Winterizing Your Pump.......................................................................15
Maintenance Schedule .......................................................................16
Troubleshooting Guide .......................................................................17,18
Spare Parts Catalogue........................................................................19,20,21
DO NOT operate this equipment until you have read
and understood all the enclosed Operator's Manual.
READ ALL the sections in this manual PRIOR to attemp-
ting to service, maintain or operate this equipment.

3
SAFETY INSTRUCTIONS
- MACHINES SUBMITTED : Powered with : Electric, Pneumatic, Petrol or Diesel engine.
- SYMBOLS : The words WARNING and CAUTION used in safety instructions, have the following
meanings :
WARNING indicates hazards or hazardous procedures which could result in serious injury or
death , if the WARNING is not observed.
CAUTION indicates hazards or hazardous procedures which could result in injury or damage
to equipment if the WARNING is not observed.
- IMPORTANT RULES FOR YOUR SAFETY :
WARNING
The machine must not be modified without prior consent of the manufacturer. Use only original
parts. If modifications are made without prior consent of the manufacturer there is a risk of serious
injury to the personal.
− These safety recommendations have been compiled from international safety standards.
Local regulations must also be checked and observed. Before using the machine, read
carefully these instructions and keep them in a safe place.
− Make sure that the signs about using, safety, and maintenance are always legible.
− The use of the machine is restricted to the applications specified in the product literature.
− Always change damaged parts immediately. Change wear parts in due time.
- SAFETY EQUIPMENT : WARNING
The admissible sound level of 85 dB (A), can be exceeded because of the machine and/or the
application. Long time exposure to loud noise without ear protectors can cause permanent damage
to hearing.
Long time exposure to vibrations can damage the hands, fingers and wrists. Do not use the machine
if you are experiencing discomfort, cramp or pain. Consult a doctor before working again with the
machine.
− Always use approved safety equipment. The following safety equipment applies to operators
and other personnel in the immediate vicinity of the working zone.
− Safety helmet.
− Ear protectors.
− Dust mask in dusty environments.
− Protective gloves.
− Protective shoes.
− Goggles.
To avoid the risk of clothes being caught in the machine, avoid wearing loose-lifting clothes. If you have long
hair, cover it with a hair net.
- WORKING AREA :
WARNING
Do not use the machine in explosive environments.
Do not operate a machine powered by a petrol or diesel engine in poorly ventilated spaces. These
types of engines produce toxic gases which can cause serious health troubles.

4
-POWER SUPPLY :
WARNING
Make sure that the power supply equipment complies with the relevant safety requirements of the
local and the international standards.
- Electric machine : It must be ensured that the machine is connected to the voltage and the
frequency specified on the name plate. The power supply cable has to be properly sized. Check that the
cable and the plug of the machine are not damaged. Never switch off the machine by pulling the plug from
its socket. Use the machine switch. Keep the cable out of the moving parts of the machine.
- Pneumatic machine : Check that the compressed-air hose and the hose coupling are not
damaged. Never attempt to loosen a compressed-air hose which is pressurized. First switch off the air at the
compressor and then leave the machine running itself to discharge the hose after some seconds.
- Machine powered by petrol or diesel engine : Petrol has an extremely low flash-point and can be
explosive in certain situations. Keep away from all hot or spark-generating objects, do not smoke, when
handling fuel. Wait until the machine has cooled before filling the tank. Avoid spilling petrol or diesel on the
ground.
-STARTING THE MACHINE :
CAUTION
Before starting make yourself familiar with the machine and make sure that the machine does not
show any obvious faults. Then start the machine according the instruction and spare parts
catalogue.
-OPERATION :
CAUTION
Use the machine only for the purpose for which it is intended. Make sure you know how to stop the
machine quickly in the event of an emergency situation. Do not touch rotating parts during
operation.
-MAINTENANCE :
CAUTION
Maintenance work must only be carried out by skilled personnel. Keep unauthorized persons away
from the machine. Do not carry out maintenance work while the machine is moving or the engine is
running. Never use a machine which is damaged.
-BE ALERT :
CAUTION
Always concentrate on what you are doing. Use common sense. Never operate the machine if you
are tired or under the influence of drugs alcohol or other substances which can affect your vision,
reaction, ability or judgement.

5
TECHNICAL DATA
Type of Current 1-phase – 50 Hz
Voltage 230V
Power 650W
Rated Current 3.5A
Maximum Capacity (Q. Max) 250 liter/min (15m3/h)
Max. Water Temp 35o
Particle Max. 5 mm
Max. height of water (H. max) 11m
Weight (without cable) 13.3kg
Height 38cm
Diameter 18cm
CE- approved

6
PRE-OPERATION NOTES
The warranty will be void if the pump has not been operated and maintained
in the manner prescribed in this Operator's Manual.
In order for the pump to perform at its optimum capabilities, the operator of
the unit must read this manual thoroughly before using this unit. This
Operator's Manual contains important product operation procedures, safety
precautions, maintenance and troubleshooting tips as well as other
advisories. Please keep this manual nearby when operating the pump as a
reference should any questions arise.
This submersible pump is ONLY for use in water. DO NOT use in trashwater.
Any other uses or applications is strictly prohibited. DO NOT start this unit
unless it is submerged in water. DO NOT submerge this pump in any other
liquid but water.
All jobsites are different. Please ensure that when installing this pump in a
jobsite, all local bylaws and codes are followed.

7
SAFETY PRECAUTIONS
1. READ AND UNDERSTAND OPERATOR'S MANUAL PRIOR TO USE
OF SUBMERSIBLE PUMP.
2. DO NOT USE ELECTRICAL CABLE TO CARRY, LIFT OR OTHERWISE
MOVE PUMP. This will damage the cable, which can cause electrical
shocks, electrical short circuit, pump failure, personal injury and other
accidents.
Always attach rope, chain or other lines to pump
HANDLE to secure, raise, or move pump.
3. Make certain that the power source conforms to the requirements of your
equipment.
NEVER REPLACE THE PLUG TO AN ALTERNATIVE!
4. DO NOT plug pump into any NON-GROUNDED electrical outlet.
5. DO NOT connect the pump to any power source unless the unit is
operating in water.
NEVER RUN THE PUMP DRY!
6. DO NOT perform any repairs or maintenance procedures on pump
unless it has been disconnected from power source.
7. Drain all liquids from the pump before servicing any component.
8. DO NOT DROP PUMP. This will damage the internal components of
the pump causing it to malfunction.

8
9. DO NOT continue operating the pump if ANY of the following conditions
are observed:
a. Excessive vibration
b. Unusual odor or noise
Turn pump OFF immediately if any of the above conditions appear and
contact your local dealer.
10. Check hoses for weak or worn condition before each use, and making
certain that all connections are secure.
11. Periodically inspect pump and system components. Perform routine
maintenance as required. If the pump is located in an area subject to
freezing temperatures, the pump and hoses should be drained when not
in operation. See "Winterizing Your Pump" section for further details.
12. Do not come into contact with the pump once it has been started.
Pump may become hot under normal use. Allow sufficient time for the
pump to cool off before coming into contact with the unit.

9
SETTING UP THE WP300
1. Wrap threaded sections of included nipple with Teflon tape.
2. Screw prepared nipple onto the WP300 Submersible Pump.
DO NOT overtighten coupling onto the outlet as this may
lead to damaging the pumps structural integrity.
3. Connect 2" discharge hose to pump.
DO NOT use restricting-type valves at the discharge
as this will restrict the capacity of the pump.
DO NOT use hose with signs of damage or wear.
4. Verify that the discharge hose will run as straight as possible.
Any excessive bending in the hose will prevent water flow.
This prevents sufficient lift, and will cause the pump to
run under its optimum capacity.
Any crimps, loops and excessive extended sections on
the hose will also create air pockets in the hose, thereby
forcing the discharged liquid back into the pump.
This will damage the pump and can result in electrical
short, leakage and/or other hazards to the operator
and jobsite.
DO NOT use extension cords with this product.

10
PRE-OPERATING PROCEDURES
Before attempting to operate the WP300 Submersible Pump, please
perform the following procedures for the personal and property
safety of the operator and jobsite.
1. Ensure that the pump is structurally and mechanically safe by
checking the following:
a. Does the pump start when plugged into socket?
Does the pump function without excessive noise
and/or unusual odour? Test as follows:
a. Set up pump as instructed in "Setting up the WP300"
section.
b. Plug electrical cable into socket.
c. Run pump for no longer than 2-3 seconds to check for
noise and odour.
NEVER RUN THE PUMP DRY!
This pump DOES NOT have an on/off switch!
Clear impeller of any debris and sand before
operating pump.
b. Check the entire length of the electrical cable, impeller,
and connector fittings are not worn, fouled or in any other
conditions that would prevent the pump from safe operation.
DO NOT USE IF ELECTRICAL CABLE IS FRAYED OR
DAMAGED IN ANY MANNER.
If any of the above checks fail, please take necessary steps to
repair the unit before operating it in any environment.
Table of contents
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual