7
5) Feed cable Cfrom luminaire Athrough pivot I
on column X, while connecting luminaire A
ZLWKFROXPQƂWWHUBE\VOLGLQJVOLSƂWWHUHover
pivot I. Turn luminaire Atowards object to
EHLOOXPLQDWHG(QVXUHVOLSƂWWHUHis properly
seated on pivot I, then tighten screw M.
7) Connect leads of luminaire cable Cand main
supply cable Gto respective terminals of
socket Sin connecting box J:
a) ON/OFF (L = Phase, N = Neutral,
= Earthing)
b) 1-10 V/DALI (L = Phase, N = Neutral,
= Earthing, DA/DA = DALI control line,
D–/D+ = 1-10 V control line).
Attention: (QVXUHFRQQHFWLQJER[LVƂUPO\
tightened for proper sealing.
8) Loosen screws Nand O slightly. Then aim
luminaire in desired direction and tighten
screws Nand O.
6) Check that rating shown on luminaire label
conforms with mains electrical supply.
(example)
FLD121-LED 220-240V50-60/Hz
145-XXXX SOE XXXXXXX
LED 3000K 12W item no. XXX
04/19 IP66