waterpowered pink SHOWER Basic User manual

C2
F
D
H
x2
2
J
J2
XYK
WZ
A2
A1
B
C
E (oponal)
x10
General Paern
G
Included only in
“Travel” version
“Special filter” packet

3
1
45
2a
3a
2b
1.1
3b
1.2
XY
K
Z
A1
A1
A2
A2
K
W
Filter assembly to the tap

4
Addy Assembly
(From ref. 6 to ref. 14 only for “Travel” version -
for use at home see from ref. 1 to ref. 4)
Aenon: for “Basic” version go to ref. 15
6
9
7
8
OK NO
OK NO
min 16mm
min
5mm
max 25mm

5
12
14
10
13
11
OK NO
NO
NO
OK
OK

6
15
16a
Use
17
16b
Only for “Travel” version
C2DC

7
19
21 22
18
20
Only for “Travel” version

8
EN USER GUIDE
WHAT IS PINK SHOWER?
Pink Shower is a medical device for domesc
vaginal douches.
WHY USE PINK SHOWER
Pink Shower is used to remove residual blood
inside the vagina aer menstrual cycle, to
perform a thorough cleaning or to soen and
expel excess vaginal secreons.
Pink Shower is recommended for proper
vaginal hygiene, vaginis, pre-post
menopause syndrome.
It is always necessary to consult a doctor
before using the device.
CONTRAINDICATIONS
Pink Shower must not be used in cases of:
post-operaon and post menopause vaginal
dryness, pregnancy; in health condions
that require special precauons, in some
cases of skin hypersensivity caused by
irritaon, wounds, bruises, surgeries and/for
other inflammaons. It is always necessary
to consult your physician before using the
device.
THE PACKAGE CONTAINS:
• “Special Filter” pack containing:
○Special Aachment with internal thread (X)
○Special Aachment with external thread (Y)
○Aerator Filter (K)
○Gasket (W – with circular secon) for
Special Aachment with internal thread.
○Gasket (Z – with rectangular secon) for
Special Aachment with external thread.
• Connector (B) with 80cm spiral tube (C)
joint (D) and handle (F)
• 1,50 m. spiral tube extension (C2)
• Double filter membrane of 1,2 microns (E
- Accessory).
• Bag containing n. 10 disposable vaginal
cannulas (G) - length 11 cm - max. diameter
of insertable part 7 mm
• Key for unscrewing filters (x2 – H)
• Universal Adaptor Addy (J)* with fastening
key (J2)* – (Accessory)
• Pink Shower carrying bag
• Mullingual manual
** Only included in the “Travel” package.
FILTER ASSEMBLY*
To connect the Pink Shower aerator filter to
the tap (bath sink, shower** or bath tub):
1 - Unscrew the aerator filter of your tap and
make sure that the gasket is removed (fig
1). If necessary, use the supplied key (H) -
fig. 1.1. In case of taps with a swivel mount
filter (bidet type - fig. 1.2) hold the upper
part of the filter with one of the keys (H)
and with the other key unscrew the lower
part (the one to be replaced with Pink
Shower Filter).
2a - In case of tap with internal thread (fig.2a),
insert the aerator filter (K) inside the special
aachment the rectangular shaped gasket
(Z) on the aerator filter (fig.2a). Screw then
to the tap the filter with external thread
(A1) just assembled (fig.3a).
2b - In case of tap with external thread
(fig.2b), insert the circular shaped gasket
(W) and the aerator filter (K) inside the
special aachment with internal thread (X)
(fig.2b). Screw then to the tap the filter with
internal thread (A2) just assembled (fig.3b).
3 - Screw the new Pink Shower filter with dry
hands, using the connector (B) and turning
an-clockwise (fig.4). In case of taps with a
swivel mount filter (bidet type), with a key
(H) hold the upper part of the filter and
mount the Pink Shower filter supplied with
connector.

9
side, making sure that none of the screws is
under the neck of the tap (fig.9);
• it follows the inclinaon of the filter holder
of the tap to allow the gasket to adhere
completely and ensure the seal (fig.10);
• it is as high as possible compared to the
filter holder of the tap (fig.11).
Special Cases
• Some filter holders have a slight nook:
please make sure that the ps of the screws
do not lean against the nook to prevent
Addy from detaching.
• In case of taps that are slightly flared/
rounded (like kitchen taps), mount the
screws on the straight side of the filter
and never on flared parts to prevent the
adaptor from coming offthe tap (fig.12).
Holding Addy to the tap with the aid of your
thumb as shown in fig. 13, use the fastening
key (J2) to screw the three screws to a secure
hold on the tap, following the direcon
indicated by the arrow posioned on the
cylindrical housing of the screws (fig.14).
Once you ghten one of the screws all the
way, it is recommended for even stronger to
ghten the remaining two screws, without
forcing them (fig.14).
While ghtening the screws, be careful
not to damage the inner gasket to avoid
compromising the hold (fig.7).
INSTRUCTIONS and SUGGESTION FOR ADDY:
• For a correct use of Pink Shower it is sufficient
gradually open the tap, do not open the
water flow all at once. For a correct use of
Pink Shower it is sufficient to open the tap
not at full pressure, but just unl the water
flows from the valve located in the quick
connector.
• Inially, for the first few moments, there
* The installaon of the filter to the tap should
be done only the first me you connect Pink
Shower: the exclusive filter for tap Pink
Shower does not need to be removed and
replaced aer each use because it allows
normal use of the tap (fig.5), providing
venlaon and filtering of the water. (The
special filter Pink Shower is adaptable to
all taps UNI EN 246. Such a standard is
usually respected by all the filter taps on the
market that present an aerator that can be
unscrewed).
** Through the “mulfuncon shower joint”
present in the range of accessories and sold
separately.
To view the phases of assembly, watch videos
on www.pink-shower.com in the “video” and
“how to use it” secons.
QUICK UNIVERSAL ADAPTOR ADDY
Included only with Pink Shower Travel or you
can purchase it separately as an accessory. The
adaptor Addy (J) allows you to connect Pink
Shower to the tap in a quick and easy way,
without
having to mount the threaded filter (A1 or A2). It
is ideal for use while travelling, in a hotel or in case
of non-standard tap thread.
Addy can be connected to all the taps with water
filter with an outside diameter from 16mm to
25mm and minimum length of 5 mm (fig.6).
ASSEMBLY TO THE TAP FOR ADDY
Check that the three screws are loose and
the gasket is properly in place, without visible
deformaon (fig.7). Hold Addy as in figure
8, pushing up unl the gasket completely
adheres to the filter holder.
Place Addy under the tap making sure that:
• one of the 3 screws is aligned with the tap
and the two remaining screws are on the

10
them once they’ve reached the end of the
travel.
• For extended use of Pink Shower on the
same tap, it is recommended to use special
filters with threaded adaptors.
• Make sure the filter holder is screwed well
on the tap to prevent leakage once the
adaptor is mounted.
HOW TO USE PINK SHOWER
1. Screw a cannula (G) to the joint of Pink
Shower handle (F) (fig. 15).
2. Connect Pink Shower to tap filter (A1 o A2)
or Addy adaptor (J) with quick coupling (B)
by inserng and rotang counterclockwise
(fig. 16a e 16b); for a beer grip, connect
with dry hands.
3. Only in case where the distance between
the tap and the place chosen for the
douching (toilet, bathtub, etc..) is
greater than the length of the 80 cm (C)
preassembled tube, install the extension
(C2) and screw the end fings (fig. 17).
4. While pressing the lever of handle (F), from
the faucet control adjust water pressure
and temperature (we suggest warm water
- 37°), checking with your hand the jet of
water coming out of the cannula (Fig. 18).
5. Stop the flow of water in the handle, sit on
the toilet or bidet and, keeping the handle,
place Pink Shower between your legs,
gently inserng the cannula into the vaginal
duct (fig. 19).
6. Pressing the lever grip, start washing the
vaginal area (fig. 19).
7. Aer the douche, cease to press the handle
lever, gently pull the cannula and close the
water tap.
8. Unhook the quick coupling (B) from the
filter tap.
9. Unscrew the cannula from the handle,
could be some small leakage of water from
the upper part of Addy but this will quickly
stop. If the leakage persists or becomes
excessive, it is recommended to repeat the
process of hooking Addy to the tap.
• Don’t touch or move Addy with opened
water flow from the tap, in order to avoid
compromising the seal.
• When you are done with Addy, simply
unscrew one of the three screws to remove
it from the tap (fig.20).
• Aer using Addy it is recommended to dry
it and leave the screws slightly ghtened
controlling, however, that the ps of the
screws don’t deform the gasket (fig.7).
• If you don’t use Addy for a long me, it
is possible that upon the first re-use the
movement of the screws may be harder:
without mounng Addy to the tap,
try to unscrew and ghten the screws
several mes to unlock and facilitate the
movement without force. Should the
screws not unlock, use some lubricant spray
in the screw holes where you would insert
the fastening key.
• The use of Addy in case of excessive
pressure when
ghtening and repeated use
on the same tap, might cause light marks
on the filter holder of the tap due to contact
with the screws, being Addy intended for
use with faucets occasionally, such as while
traveling. At home or for prolonged use on
the same faucet, you should use the special
filters Pink Shower.
• It is not recommended to leave Addy
mounted to the tap, although if you do, for
each new use is recommended to check
that the hold is solid, making sure the 3
screws are well ghtened.
• When you unscrew the screws, do not force
Table of contents
Other waterpowered Personal Care Product manuals




















