WL350Manual Page76–Revision11‐21‐2018
HOTWATERTROUBLESHOOTINGINDEX
1. HotWaterisnotHot86°±‐1.5°C(187°±5°F)
Also includes related instructions for:
Disabling Energy Star Sleep Mode
Resetting the Hot Tank Overload or High Safety Limit
Programming “Changing Hot Water Mode to Ambient Water Mode”
1. HotWaterisnotHot86°±‐1.5°C(187°±5°F)
TheHotTemperaturesetpointis85°C(185°F)andiscontrolledbyathermostatonthesideofthe
HotTank.
ThereisaresettableoverloadorhighlimitsafetyabovethethermostatonthesideoftheHotTank
thatwilltriptopreventdamagetotheunitifthetankisdryheated(turnedonwithoutwaterinit).
TheWL350WaterTreatmentSystemisprogrammabletomakeCold/Ambientwater–referto
DisablingSleepModeinstructionsincludedfurtherbelowinthisTroubleshootingSection.
TheWL350WaterTreatmentSystemdoesNOThaveExtraHotcapabilityandthemaximumhot
temperatureis87°C(189°F).
Ittypicallytakes10minutesforthe500Wtoheatthe1.6Liter(0.4Gallon)ofroomtemperature
(ambient)watertothe85°C(185°F)setpoint.
PossibleReason Solution
NoPower
CheckthattheRedHeater&Compressorswitchison.
TurnRedHeater&CompressorSwitchon.
I=ON
IsunitinEnergyStar
SleepMode?
Ifnowaterhasbeendispensedfor3ormorehours,unitgoesintosleep
mode.Dispensehotwater,wait5minutes,checktemperature.
Ifunitstilldoesnotheatproceedto“NopowertoHeaterelements”below.
IfunitdoesheatbutyouwouldliketoDisableSleepMode,refertothe
instructionsincludedfurtherbelowinthisTroubleshootingSection
HotTankOverload
Tripped
Overloadisasafety
featuretoensurethe
tankdoesnot
overheat.
Overloadwill“click”whenpushed.Theoverloadisautomaticallyresetwhen
pressed.
SeeResettingtheHotTankOverloadorHighLimitSafetyInstructionsthat
areincludedfurtherbelowinthisTroubleshootingSection