Vitec Multimedia FIM-102D User manual

FIM-102D MATRIX FIBER INTERFACE
INSTRUCTION MANUAL

FIM-102D Matrix Fiber Interface Instruction Manual
©2004 Vitec Group Communications
All Rights Reserved
Part Number 810319
Vitec Group Commmunications, Inc.
4065 Hollis Street
Emeryville, CA 94608-3505
U.S.A.
A Vitec Group Company
Clear-Com is a registered trademark of Vitec Group Communications.
The Clear-Com Logo is a registered trademark of Vitec Group Communications.

FIM-102D FIBER INTERFACE i
CONTENTS
OPERATION............................................................................................................................................ 1-1
Description .................................................................................................................................................................1-1
Connecting Intercom Stations To The Central Matrix ..................................................................................1-1
Connecting Interface Modules To The Central Matrix..................................................................................1-5
Using The FIM-102D In Conjunction With The EF-1M As A Stand-Alone Party Line Extender.......1-6
FIM-102D Two Fiber Configuration.....................................................................................................................1-6
FIM-102D Front Panel Connectors And Lights..................................................................................................1-8
FIM-102D Rear Panel Connectors.........................................................................................................................1-10
INSTALLATION ........................................................................................................................................ 2-1
Unpacking...................................................................................................................................................................2-1
Installing and FIM-102D Unit In A Rack .............................................................................................................2-2
Installing Fiber Optic Cable.....................................................................................................................................2-2
Maximum Fiber Lengths.....................................................................................................................................2-3
Connecting Fiber Optic Cable To The FIM-102.................................................................................................2-5
Connecting Audio/Data Cables To The FIM-102D ..........................................................................................2-7
CAT-5 Cable Pinout Diagram............................................................................................................................2-8

ii FIM-102D FIBER INTERFACE
MAINTENANCE........................................................................................................................................ 3-1
Troubleshooting Tips ...............................................................................................................................................3-1
Preventative Maintenance ........................................................................................................................................3-3
GLOSSARY............................................................................................................................................... 4-1
SPECIFICATIONS ..................................................................................................................................... 5-1
CLEAR-COM LIMITED WARRANTY .......................................................................................................... 6-1
Factory Service...........................................................................................................................................................6-2
Warranty Repair.........................................................................................................................................................6-3
Non-Warranty Repair ...............................................................................................................................................6-3

FIM-102D FIBER INTERFACE 1-1
1OPERATION
DESCRIPTION
With a Clear-Com FIM-102D System, you can connect Clear-Com intercom stations or interfaces to the central
Matrix using fiber-optic cables at distances of up to 12 miles (20 km).
The system consists of one FIM-102D at the Matrix-frame end and another FIM-102D unit at the Matrix-station end.
Connecting the pair of interfaces with fiber rather than with the standard 4-wire twisted copper, gives you advantages
such as increased security from electromagnetic and RF interference, flexibility in equipment placement, ease of
maintenance and often, reduced cost.

1-2FIM-102D FIBER INTERFACE
CONNECTING INTERCOM STATIONS TO THE CENTRAL MATRIX
The Clear-Com FIM-102D system transmits audio and data signals from 1 or 2 intercom stations or interfaces to the
Matrix frame through the process illustrated in Figure 2.
Figure 1: Connecting Intercom Stations to the Central Matrix

FIM-102D FIBER INTERFACE 1-3

1-4FIM-102D FIBER INTERFACE
1. Matrix Plus intercom stations transmit analog audio signals and digital data signals to the first FIM-102D unit via
copper cable terminated with RJ-45 connectors.
2. The first FIM-102D unit converts the analog audio signals to digital audio signals through an analog-to-digital
converter (ADC) located on the FIM-102D unit’s main circuit board.
3. The first FIM-102D unit then multiplexes (combines) the digital audio signals with the already digital data signals.
4. The first FIM-102D then converts the multiplexed digital signal into an optical signal.
5. The first FIM-102D then transmits the optical signal over up to 12 miles (20 km) of fiber-optical cable to the
second FIM-102D unit, where a similar but reverse process occurs to convert the signal back to its original format.
6. The second FIM-102D unit converts the received optical signal to a digital signal.
7. The second FIM-102D then “demultiplexes” (separates) the digital signal back into it’s separate audio and data
signals for each intercom unit.
8. The second FIM-102D then converts the digital audio signals for each intercom station to analog audio signals by
sending the signals through a digital-to-analog converter (DAC) located on the FIM-102D unit’s main circuit board.
9. The second FIM-102D unit then transmits the analog audio and digital data signals for each intercom station to the
central Matrix over copper cable terminated with RJ-45 connectors.

FIM-102D FIBER INTERFACE 1-5
10. The central Matrix receives the intercom stations’ audio and data signals in the same format in which they were
originally sent by the Matrix Plus 3 intercom stations.
WARNING: Always use extreme caution with fiber-optic equipment. Never look directly into the light port or into
the end of the optical fiber while either FIM-102D unit is operating. Even if you do not see visible light, eye
damage is possible.
CIRCUIT DESCRIPTION
Analog-to-Digital Converters High speed analog-to-digital converters for each audio channel.
Multiplexer Sequentially presents two RS-422 digital inputs and two digitized audio signals from the A/D converters to the
optical output driver.
Demultiplex-er Takes sequential digital signals from the pin diode and separates them into 4 separate lines: two to the D/A
converters and two to the RS-422 transmitters.
Digital-to-Analog Converters Hi
g
h speed di
g
ital-to-analo
g
converters for each audio channel convert the di
g
itized audio si
g
nal back to analo
g
audio.

1-6FIM-102D FIBER INTERFACE
CONNECTING INTERFACE MODULES TO THE CENTRAL MATRIX
With a pair of FIM-102D units you can also remotely connect Clear-Com rack-mounted Matrix interface modules to
the central Matrix. For example, using a Clear-Com CCI-22 dual party-line interface at one end, you can connect two
independent, external 2-wire party line systems to the central Matrix from a distance of up to 12 miles (20 km). Or,
with a Clear-Com TEL-14 Telephone Interface Module, you can send telephone audio to the central Matrix over a
secured interference-free fiber-optic line. By using a Clear-Com FOR-22 4-wire interface module, you can send 4-
wire audio plus transmit keying over a fiber-optic line. You can also use a Clear-Com EF-1M to interface 2-wire
Clear-Com or RTS party lines to the central Matrix over a fiber-optic link.
Figure 2 shows a system with connected interface modules.
FIM-102D FIM-102D
CCI-22 Interface
TEL-14 Interface
Connects two 2-wire
party-line circuits
Connects 2 tele-
phone lines
EFI-M Interface
Connects 2-wire
party-line to matrix
or other 4-wire devices
or
or
Figure 2: Connecting Interface Modules to the Central Matrix
Table of contents
Other Vitec Multimedia Recording Equipment manuals