Vimco Lutron Sivoia Manual

Page 1
shading solutions byVIMCOTM
1System Dimensions Overview pg. 3
2Fasten Mounting Brackets pg. 4,5
3Attaching MDU and Idler Support pg. 6
4Hanging the Shade pg. 6,7
5Wiring the System pg. 8,9
6MDU Setup pg. 10,11
7Shade Controls pg. 12
8MDU w/ SV-IR Module pg. 13
9Troubleshooting pg. 14
10 Part Specs pg. 15
Contents
Infrared Handheld
Transmitter
Idler
Support
Fabric & Roller Assembly
Motor Drive Unit (MDU)
Wallstation Controls
Transformer
SV-IR Infrared Receiver Module
A Typical SivoiaTM Motorized Shade System
(Wallstation Controls, Transformer, SV-IR Infrared Receiver Module, and Infrared Handheld Transmitter not included with this kit)
Installation & Operating Instructions
Single Shade
Installation Kit
Motorized Shade Systems
®

Page 2
shading solutions byVIMCOTM
CARTON CONTENTS
Motor Drive Unit (MDU)
(exploded view - ships assembled)
SV-IR Module Connecting
Wire (SV-IR Module sold
separately)
MDU & Idler Support Mounting
Brackets
MDU & Idler Support
Ceiling-Mount Brackets
Idler Support
1/2” Idler and MDU
Truss-head Screws
(x8)
2” Pan-Head Mounting
Bracket Screws (x8)
• #2 Phillips Screwdriver
• 1/8 in. Straight Blade Screwdriver
• Power Drill: Drill Bits, Screwdriver Attachments
• Level
• Pliers
• Tape Measure
• Wire Cutter
• Wire Stripper
TOOLS REQUIRED

Page 3
shading solutions byVIMCOTM
SYSTEM DIMENSIONS OVERVIEW
Use the following diagrams in conjunction with the Sivoia®Order Invoice to accurately position the mounting brackets.
Bracket to Bracket Width
(FW + 4" (102 mm))
Fabric Width (FW)
2 3/4"
(70 mm)
1 1/4"
(32 mm)
Bracket to Bracket Width
(FW + 4" (102 mm))
Fabric Width (FW)
2 3/4"
(70 mm)
1 1/4"
(32 mm)
Figure 1: Standard Mounting Bracket Application
Figure 2: Ceiling-Mount Bracket Application
1

Page 4
shading solutions byVIMCOTM
FASTEN MOUNTING BRACKETS
A. Position the bracket’s “teeth” for each bracket at the ends of the fabric width as shown. Use a level to ensure the
brackets are at the same height and parallel to the window casing.
Note: Fasten the top of the brackets 5 in. (127 mm) from the top of the window trim to ensure complete window
exposure when the shades are in full up position.
B. Fasten the brackets to studs in the wall using no less than four(4) pan-head mounting bracket screws.
Note: All four (4) screws must be securely fastened to stud or other structural member.
Fabric Width
5"
(127mm) 5"
(127mm)
A
B
Fabric Edge
Fabric Edge
Teeth
Line up the bracket teeth with the
fabric edge
Once the mounting brackets have been fastened to the wall, confirm the Bracket to Bracket Width
as listed on the Sivoia®Order Invoice. Refer to Figure 1 on page 3 for a detailed diagram. Make any
necessary bracket position adjustments based on this assessment.
Note: Only mount system where ambient temperature will be 0˚C - 50˚C (32˚F - 122˚F).
2

Page 5
shading solutions byVIMCOTM
FASTEN MOUNTING BRACKETS (CONT’D)
For Ceiling-Mount Applications...
Follow steps A & B from the previous page, then line up and fasten the brackets as shown.
Notes:
•Make sure the opening of the ceiling bracket faces outward towards the room.
•All four (4) screws must be securely fastened to stud or other structural member.
Fabric Edge
Wall
Ceiling
Bracket
Top View
5"
(127mm)
Line up this bracket edge with the
fabric edge
Face this
opening outward
towards the room
when mounting
Once the ceiling-mount brackets have been fastened to the ceiling, confirm the Bracket to Bracket
Width as listed on the Sivoia®Order Invoice. Refer to Figure 2 on page 3 for a detailed diagram.
Make any necessary bracket position adjustments based on this assessment.
2

Page 6
shading solutions byVIMCOTM
ATTACH MDU and IDLER SUPPORT
A. Attach the idler support to the mounting bracket using
three (3) truss-head screws.
B. Attach the MDU to the mounting bracket using three (3)
truss-head screws.
HANGING THE SHADE
A. Unwrap approximately 1 ft. (0.3 m) of material.
B. Attach the shade to the MDU first by engaging the roller’s hexagonal socket with the motor’s hexagonal drive ball. You
may need to rotate the roller in order to push the shade over the hexagonal drive ball.
C. Insert the idler pin into the upper slot of the idler support and drop it into place.
B
C
3
4

Page 7
shading solutions byVIMCOTM
HANGING THE SHADE (CONT’D)
D. Tighten the idler's shade retaining screw to keep the
idler pin secure/ “locked”.
E. Adjust the shade leveling screw to level the shade
roller.
D
D
E
E
Shade Retaining
Screw “Locked”
Shade Retaining
Screw
Shade
Leveling
Screw
CAUTION! Not setting the shade retaining screw into the
"locked" position prior to operating the unit can result in
damage to the system.
4

Page 8
shading solutions byVIMCOTM
A
C
12345678
Cntrl 1
Cntrl 2
Ground
AC
AC
Com
MUX
MUX
B
Do not connect if there is only one MDU in the system. If
there are multiple MDU's in the system, the MDU's must be wired
together. Connect the MUX, Drain, and MUX terminals of each MDU
together in a daisy chain or homerun configuration.
To a Sivoia®wall mounted keypad, or a Sivoia®interface such
as the SV-CCI-GRP or the SV-GRXI. The CNTRL1 and CNTRL2
wires are polarity sensitive.
MDU WIRING - SINGLE MOTOR
Connecting Wires to the MDU Terminal Block
The terminal block located at the bottom of the MDU is the wire
connection point for: power, communication, keypads, and interfaces.
A. Remove terminal block cover (if not yet removed) by pressing in on
the cover and then pulling downward.
B. Grasp terminal block and pull down to separate from connecting
block.
C. Connect wires to the terminal block according to the diagram
below.
D. Replace the terminal block and the terminal block cover.
Wire to a Sivoia®plug-in transformer, junction box mount
transformer, or a Sivoia®power panel. Each MDU must be EARTH
grounded. One Sivoia®transformer can power ONLY ONE MDU
regardless of shade size.
A
B
Control
Comm
Link
Power
Supply
Comm & Power
( & combined)
Wire Type
Control
Description
2 conductors / #22-24 AWG
3 conductors (2 shielded, 1 common) / #24 AWG
Belden®wire model #1883A
3 conductors #22 AWG
Lutron model # SV-IR-EXT-10
3 conductors:
2 / #18-22 AWG (24 VAC power supply)
1 / #18-22 AWG (earth ground)
6 conductors:
2 / #16 AWG (24 VAC power supply)
1 / #18 AWG (earth ground)
3 #22 AWG shielded + 1 #24 AWG common (comm link)
(Lutron wire model no. SV-CBL-MDU-250)
Control to MDU: 250 ft. (76 m)
Max. Length
4000 ft. (1333 m) per system
1000 ft. (333 m) from MDU to MDU
50 ft. (15 m) per system - total of 5
SV-IR-EXT-10, 10 ft. (3 m) each
MDU to Sivoia®power panel:
200 ft. (61 m)
Transformer to MDU:
#18 AWG - 150 ft. (46 m)
#20 AWG - 100 ft. (31 m)
#22 AWG - 60 ft. (18 m)
A
Comm Link B
B
D
Power Wires C
C
SV-IR Extension
Cable E
5

B
C
Com
MUX
MUX
12345678
Cntrl 1
Cntrl 2
Ground
AC
AC
Com
MUX
MUX
A
C
12345678
Cntrl 1
Cntrl 2
Ground
AC
AC
Com
MUX
MUX
AC
G
N
D
B B
A
AC
Comm & Power
( & combined)
Page 9
shading solutions byVIMCOTM
MDU WIRING - WIRING MULTIPLE MOTORS TOGETHER
Wire to a Sivoia®plug-in transformer, junction box mount
transformer, or a Sivoia®power panel. Each MDU must be
EARTH grounded. One Sivoia®transformer can power ONLY
ONE MDU regardless of shade size.
To a Sivoia®wall
mounted keypad, or
a Sivoia®interface
To a Sivoia®wall
mounted keypad, or
a Sivoia®interface
A maximum of 64 MDU's can be wired
together per system
MDU Terminal Blocks
Control
Comm Link
Comm Link
Power
Supply
Control
Next
MDU
Next
MDU
Comm Link
Power Supply
Wire Type
Control
Description
2 conductors / #22-24 AWG
3 conductors (2 shielded, 1 common) / #24 AWG
Belden®wire model #1883A
3 conductors #22 AWG
Lutron model # SV-IR-EXT-10
3 conductors:
2 / #18-22 AWG (24 VAC power supply)
1 / #18-22 AWG (earth ground)
6 conductors:
2 / #16 AWG (24 VAC power supply)
1 / #18 AWG (earth ground)
3 #22 AWG shielded + 1 #24 AWG common (comm link)
(Lutron wire model no. SV-CBL-MDU-250)
Control to MDU: 250 ft. (76 m)
Max. Length
4000 ft. (1333 m) per system
1000 ft. (333 m) from MDU to MDU
50 ft. (15 m) per system - total of 5
SV-IR-EXT-10, 10 ft. (3 m) each
MDU to Sivoia®power panel:
200 ft. (61 m)
Transformer to MDU:
#18 AWG - 150 ft. (46 m)
#20 AWG - 100 ft. (31 m)
#22 AWG - 60 ft. (18 m)
A
Comm Link B
B
D
Power Wires C
C
SV-IR Extension
Cable E
5

Press the Set button to save the
corrent position as the “Close
Limit.” The display will read
and blink for 4 seconds, then go
blank.
SET
OPEN
CLOSE
MODE
Page 10
shading solutions byVIMCOTM
MOTOR DRIVE UNIT (MDU) SETUP - SINGLE MDU
Open Limit: The position the shade moves to when it opens.
Close Limit: The position the shade moves to when it closes.
Programming Table
STEPS MODE
Open Limit:
Press the Mode
button on the MDU
until the display
reads
Close Limit:
Press the Mode
button on the MDU
until the display
reads
STEP 2
Use the Open and Close buttons on the
MDU to adjust the shade to the open
position desired.
Use the Open and Close buttons on the
MDU to adjust the shade to the closed
position desired.
Press the Set button to save the
corrent position as the “Open
Limit.” The display will read
and blink for 4 seconds, then go
blank.
ADJUST SET
Mode Button
Open and Close
Buttons
Set Button
Display on bottom of MDU
STEP 1
6
The Motor Drive Unit (MDU) should come from the factory with open and close limits. To change the factory limits,
follow the steps below. If there is only one MDU in the system, open and close limits are the only steps required.
Follow the programming steps outlined in the programming table below. If the system has multiple MDUs, follow the
single MDU setup directions for each MDU and then continue with the setup codes for multiple MDU systems on the
next page.
Other Vimco Window Blind manuals
Popular Window Blind manuals by other brands

Current
Current E-WAND Installation manual and user's guide

weinor
weinor VertiTex ZipR Maintenance Instructions and Directions for use for the end user

Roto
Roto ZAR M R4/R7 Mounting instructions

SOMFY
SOMFY Movelite WT Series instructions

Acmeda
Acmeda RF400 Series instructions

Motura
Motura Pli_353/3 manual