Videx 2213 User manual

2213 REMOTE RELAY
Remote Relay for the VX2200 System
2213-66251540-EN
V2.0
10/10/22
Technical Manual
ENG
We recommend that this equipment is
installed by a Competent Electrician,
Security or Communications Engineer.

2213-66251540-EN - V2.0 - 10/10/22
- 2 -
2213 Remote Relay - Technical Manual
2213 Remote Relay for the VX2200 System
All Countries:
VIDEX ELECTRONICS S.P.A.
www.videx.it - technical@videx.it
Tel: +39 0734-631699 - Fax: +39 0734-632475
UK Customers:
VIDEX SECURITY LTD.
Tech Line: 0191 224 3174
CUSTOMER SUPPORT
Theproduct isCEmarkeddemonstratingits conformity and isfordistribution
within all member states of the EU with no restrictions. This product follows
the provisions of the European Directives 2014/30/EU (EMC); 2014/35/EU
(LVD); 2011/65/EU (RoHS): CE marking 93/68/EEC.
DECLARATION OF RESPONSIBILITY
This technical manual has been written and revised carefully. The guidance and the descriptions which are included in it are in
reference to VIDEX parts and are correct at the time of print. However, subsequent VIDEX parts and technical manuals, can be
subject to changes without prior notice. VIDEX Electronics S.P.A. and VIDEX Security Ltd. (UK) cannot be held responsible for
damages caused directly or indirectly by errors, omissions or discrepancies between the VIDEX parts and the technical manual.
The product is UKCA marked demonstrating its conformity and is for
distributionwithintheUK.Thisproduct followsthe provisionsofthefollowing
UK legislation: Electromagnetic Compatibility Regulations 2016; Electrical
Equipment (Safety) Regulations 2016; Radio Equipment Regulations 2017
and The Restriction of the Use of Certain Hazardous Substances in Electrical
and Electronic Equipment Regulations 2012 (RoHS).
MANUFACTURER
VIDEX ELECTRONICS S.P.A.
Via del Lavoro, 1 - 63846 Monte Gilberto (FM) Italy
Tel: (+39) 0734-631699 - Fax: (+39) 0734-632475
THE POWER TO SECURE
IT IS RECOMMENDED THAT THIS VIDEX PRODUCT IS INSTALLED BY A COMPETENT AND QUALIFIED
ELECTRICIAN, SECURITY INSTALLATION SPECIALIST OR COMMUNICATIONS ENGINEER.
Contents
Manual Introduction .........................................................................................................................................................................3
Description and Operation...............................................................................................................................................................3
Relay Terminal Connections .............................................................................................................................................................3
Dip-switch Settings ...........................................................................................................................................................................4
Installation Notes ..............................................................................................................................................................................6
Lock Release Wiring and back EMF Protection ...............................................................................................................................6
Technical Specication......................................................................................................................................................................6
Wiring Diagram..................................................................................................................................................................................7
Notes...................................................................................................................................................................................................8

2213-66251540-EN - V2.0 - 10/10/22
3
2213 Remote Relay - Technical Manual
2213 Remote Relay for the VX2200 System
MANUAL INTRODUCTION
The information in this manual is intended as an installation and commissioning guide for the 2213LIFT remote relay. This manual
should be read carefully before the installation commences.
Any damage caused to the equipment due to faulty installation where the information in this manual has not been followed is not the
responsibility of VIDEX Electronics S.P.A. and VIDEX Security Ltd (UK).
It is recommended that the remote relay is installed by a competent electrician, security or communications engineer.
For UK customers Videx run free training courses for engineers who are unfamilier or who have not installed this product before.
Technical help is also available for UK and Rep. of Ireland customers from the Videx technical helpline on tel: 0191 224 3174 during
For all other overseas customers including Europe technical help is available on tel: +39 0734 631 669 or via e-mail: [email protected].
A copy of this technical manual can also be downloaded from the Videx websites: www.videxuk.com, www.videx.it.
DESCRIPTION AND OPERATION
The 2213 remote relay module is designed to work on the VX2200 system. All entrance panels on the VX2200 system include the
lock release relay and push to exit button input inside the entrance panel. For higher security applications including installations in
compliance with Secured by Design the 2213 enables the relay and push to exit button input to be installed in a secure location away
from the entrance. Setting up of the module is achieved using the 8 way dip-switches.
The 2213 device number should be set to match the device number (panel ID) of the entrance panel it is associated with using dip
switches 1-4. When the relay command is received from an audiophone or videophone, from an digital entry panel (via the coded
access facility) or a concierge the relay will activate for the programmed relay time (setup using dip-switches 5-7).
Activating the PTE input on the 2213 will also trigger the relay for the programmed relay time. Lock release cables and push to exit
cables should not run through the entrance panel back box or any unsecure locations to maintain the highest security possible. The
relay in the entrance panel along with the PTE input in the entrance panel will not be used and should remain disconnected (in the
event of someone activating the PTE input on the entrance panel it will have not eect on the 2213 remote relay).
The 2213 can also be setup in local mode (default) or main mode (using dip-switch 8) for larger systems that have main entrances
and local/sub entrances where 2206N bus exchange devices are used. The module includes connections for 12Vdc power, digital BUS
connections (L, -) and a set of relay contacts (CO, NO, NC).
RELAY TERMINAL CONNECTIONS
Refer to the table below for the 2213 terminal connections and the unit layout and dimensions in Fig.1.
22
66
50
60
A B C D E F
LEGEND
Firmware version - FW10.LX
Relay (NC/NO/CO) terminals
8 way programmable dip-switches
PTE input (switched 0V)
Databus input (L/-)
+12Vdc power input
Fig. 1
Terminal Description Terminal Description
12Vdc 12-14Vdc input from power supply PTE Push to exit input (switched 0V push to make)
GND 0V input from power supply CO Common relay connection
-Databus 0V connection NO Normally open relay connection
LDatabus connection (+pos) NC Normally closed relay connection

2213-66251540-EN - V2.0 - 10/10/22
4
2213 Remote Relay - Technical Manual
2213 Remote Relay for the VX2200 System
DIPSWITCH SETTINGS
Dip-switches SW1 to SW4 (see Fig.2) sets up the device number (panel ID) of the 2213 remote relay.
Setting Device Number
Device No. (Panel ID) SW1 SW2 SW3 SW4 Switch Position
1OFF OFF OFF OFF
56781234
ON
2ON OFF OFF OFF
56781234
ON
3OFF ON OFF OFF
56781234
ON
4ON ON OFF OFF
56781234
ON
5OFF OFF ON OFF
56781234
ON
6ON OFF ON OFF
56781234
ON
7OFF ON ON OFF
56781234
ON
8ON ON ON OFF
56781234
ON
9OFF OFF OFF ON
56781234
ON
10 ON OFF OFF ON
56781234
ON
11 OFF ON OFF ON
56781234
ON
12 ON ON OFF ON
56781234
ON
13 OFF OFF ON ON
56781234
ON
14 ON OFF ON ON
56781234
ON
15 OFF ON ON ON
56781234
ON
16 ON ON ON ON
56781234
ON
12345678
Unit Address
NC NO CO
12Vdc GND _PTEL
2213N
VX2200 Remote Relay
VIDEX
12345678
Fig. 2 SW1 to SW4

2213-66251540-EN - V2.0 - 10/10/22
5
2213 Remote Relay - Technical Manual
2213 Remote Relay for the VX2200 System
Dip-switches SW5 to SW7 (see Fig.3) sets up the relay time of the 2213.
Setting the Relay Time
Relay Time SW5 SW6 SW7 Switch Position
1 second OFF OFF OFF
56781234
ON
2 seconds ON OFF OFF
56781234
ON
4 seconds OFF ON OFF
56781234
ON
6 seconds ON ON OFF
56781234
ON
8 seconds OFF OFF ON
56781234
ON
10 seconds ON OFF ON
56781234
ON
12 seconds OFF ON ON
56781234
ON
15 seconds ON ON ON
56781234
ON
12345678
Unit Address
NC NO CO
12Vdc GND _PTEL
2213N
VX2200 Remote Relay
VIDEX
1234567856781234
Fig. 3 SW5 to SW7
Dip-switch SW8 (see Fig.4) sets up the operating mode of the 2213 remote relay, as shown in the table below.
Setting Mode
Operating Mode SW8 Switch Position
Local mode (default) OFF
56781234
ON
Main mode ON
56781234
ON
12345678
Unit Address
NC NO CO
12Vdc GND _PTEL
2213N
VX2200 Remote Relay
VIDEX
123456785678123456781234
Fig. 4 SW8

2213-66251540-EN - V2.0 - 10/10/22
6
2213 Remote Relay - Technical Manual
2213 Remote Relay for the VX2200 System
INSTALLATION NOTES
When installing the 2213LIFT remote relay follow the list of installation checks below:
• Check that all components are free from damage before installing, do not proceed with the installation in the event of
damage.
• Keep all packaging away from children (please dispose of any excess waste and packaging responsibly).
• Do not obstruct the ventilation openings or slots on any of the devices.
• All connections to mains voltages must be made to the current recognised national standards: I.E.T. Wiring Regulations,
Eighteenth Edition BS7671:2018 for the UK or the appropriate standards of your country if installing overseas.
• Install an appropriate fused spur or isolation switch to isolate the mains supply.
• Isolate the mains supply before carrying out any maintenance work on the system.
• Avoid water ingress into the module.
• If an electric lock is to be tted to the system it is important to power the lock release from a dedicated fused supply to avoid
a short in the device cabling. Remember to power down the lock release when tting it.
• All intercom and access control cables must be routed separately from the mains.
LOCK RELEASE WIRING AND BACK EMF PROTECTION
When tting an electric lock release back EMF protection will be required. If tting an AC lock release then a 100nF ceramic disc
capacitor should be tted across the terminals of the lock, shown in Fig.5. If tting a DC lock release (fail secure or fail safe) then a
1N4002 diode should be tted across the terminals on the lock, shown in Fig.6.
12V AC
LOCK RELEASE
100nF
CAP
A varistor (MOV) can be tted
to either an AC or DC lock
across the lock terminals and
is not polarity conscious
DIODE
1N4002
12V DC
LOCK RELEASE
Fig. 5 Fig. 6
If a 100nF ceramic disc capacitor or a 1N4002 diode are not available then a 14 - 20V MOV (metal oxide varistor) can be tted across
the lock terminals instead (refer to Fig.5 above) and can be tted on both an AC and DC lock. A lock release connection example
can also be seen in Fig.7 wiring diagram on page 7.
TECHNICAL SPECIFICATION
Input voltage: 12V - 14Vdc power input (+/-10%)
Current (standby): 6.4mA (max.)
Curent (during operation): 41mA (max.)
PTE input open voltage: 5Vdc
PTE input closed voltage: 0V
Databus voltage: 7.5V - 8Vdc (L/-)
Maximum cable resistance: 7Ω
Relay contacts: CO, NO and NC (10A @ 24Vdc, 12A @ 120Vac, 5A @ 250Vac)
Programming: Programming via 8 way dip-switches: device ID setup ID.1 - ID.16, relay activation time setup
(1, 2, 4, 6, 8, 10, 12 or 15 seconds), operating mode local mode (default) or main mode (to
operate with 2206N bus exchange devices).
Enclosure material: ABS plastic (white)
Enclosure dimensions (mm): 66 (W) x 60 (H) x 22 (D)
Mounting: Surface, direct wall xing

2213-66251540-EN - V2.0 - 10/10/22
7
2213 Remote Relay - Technical Manual
2213 Remote Relay for the VX2200 System
WIRING DIAGRAM
Fig.7 below shows the wiring connections for the 2213 remote relay.
Made in Italy
Dry contact output
Capacitor discharge
Balanced V1, V2
Coax V2 = V, V1
not used
RS485
BUS TERMINATION
Open
Close
V.PB.CHIP
Balance
A
B
GND
D0
D1
LR
LG
OC OUTPUT
RS485
WIEGAND
USB
12345678
12345678
ON
12Vdc
Fail Secure
Lock Release
Push to Exit
(push-to-make)
1 2 3 4 5 6 7 8
ON
12345678
ON
1 2 3 4 5 6 7 8
ON
12345678
ON
Art.3171, Art.3172 or Art.3176 PHONE ID.1
12V
GND
L
Panel set as MASTER,
Local mode and
Device (Panel) ID.1
Art.4212R
Digital Panel
Remote relay set
to ID.1, relay time
set for 6 seconds
Art.KRA76 or Art.KRA78 PHONE ID.2
CONTROL EQUIPMENT
IN SECURED LOCATION
The 12Vdc Lock release can
be activated from any of the
audiophones on the system
or by entering the correct
door access code on the
Art.4212R Digital Panel
Fig. 7

2213-66251540-EN - V2.0 - 10/10/22
- 8 -
2213 Remote Relay for the VX2200 System
2213 Remote Relay - Technical Manual
NOTES

2213-66251540-EN - V2.0 - 10/10/22
- 9 -
2213 Remote Relay for the VX2200 System
2213 Remote Relay - Technical Manual

2213-66251540-EN - V2.0 - 10/10/22
- 10 -
2213 Remote Relay for the VX2200 System
2213 Remote Relay - Technical Manual
Table of contents
Other Videx Relay manuals