Vesta Skyra User manual

Skyra
Clear Ice Maker
INSTRUCTION MANUAL

1
Introduction
Thank you for choosing our Skyra clear ice maker! This brand-new product is
designed to bulk produce clear ice in standard shapes, perfect for bars, hotels and
other businesses serving cold drinks. Compared with regular non-clear ice makers
and traditional clear ice-producing processes, the Skyra ice maker has the following
advantages:
Produce clear ice that is denser and melts more slowly than cloudy ice.
Directly form clear ice in standard shapes without cutting.
One-button automatic production of clear ice for simple operation.
Solve long-term needs for clear ice and reduce cost.
Our clear ice maker is built with a stylish look and stunning performance, having
passed rigorous safety and performance testing. Please feel free to use it and enjoy
your clear ice!

2
Contents
Important Safety Instructions .................................................................. 3
Product Structure .................................................................................... 8
Specifications ........................................................................................ 10
Product Features................................................................................... 11
Operation Instructions ........................................................................... 13
Before using................................................................................... 13
How to make clear ice.................................................................... 15
How to use Freeze mode............................................................... 20
Care and Maintenance.......................................................................... 22
Troubleshooting..................................................................................... 23

3
Important Safety Instructions
Only the power supply specified on the machine nameplate can be used with this
machine.
Outlet for this machine must meet the national laws and regulations and must
be reliably grounded with leakage protection.
Wear gloves when performing maintenance on the motor and the cooling system
inside the machine.
Do not insert a screwdriver or other device into the protective grilles, where there
are heat exchange vents, evaporators, etc.
Do not touch live parts with wet hands or bare feet.
Do not block the heat exchange vents of the compressor or evaporator to ensure
the normal operation of the machine.
When opening or closing the lid, always hold the lid to avoid getting your hands
caught.
Do not place non-food items in the machine except the accessories that come
with the machine.
Only trained operators are allowed to use this machine.
The installation, repair or maintenance of this machine must be carried out by
professional and qualified personnel.
The machine is not intended for use by children, persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge.
The machine should be properly managed to ensure that children will not play
with or around it.
If the power supply device of the machine fails, contact professional personnel
certified by the manufacturer to replace it to avoid safety accidents.
It is prohibited to modify or remove the provided safety devices (protective

4
grilles, hazard labels, etc.) and the manufacturer is not responsible for the
consequences of violating this instruction.
In the event of a fire, use a carbon dioxide fire extinguisher instead of water, and
cool the motor room as soon as possible.
Do not use mechanical devices or other means to accelerate the defrosting
process, other than those recommended by the manufacturer.
Do not damage the refrigerant circuit.
Do not use other electrical appliances in the machine, unless they are
recommended by the manufacturer.
Refrigerants and blowing agents are flammable and should only be disposed of
by qualified personnel and institutions.
If the power cord is damaged, it must be replaced by the manufacturer, service
agent, or qualified personnel.
Do not store explosive substances such as aerosol cans with a flammable
propellant in this machine.
Keep clear of obstructions to all ventilation openings of the machine.
Before performing any operation, unplug the power cord and ensure that the
operator can check from any direction that the power cord is disconnected.
The A-weighted emission sound pressure level is below 70 dB(A).
The climatic class numbers marked on the machine nameplate indicate:
- Maximum ambient temperature for appliances with climatic class 0, 1, 2, 3, 4, 6,
or 8 in the test room: 89.6°F±0.6°F.
- Maximum ambient temperature for appliances with climatic class 5 or 7 in the
test room: 109.4°F±0.6°F.
Warning: risk of fire / flammable materials

5
Package and Transportation
Packed in wood crates, the machine should be transported with appropriate
equipment, do not move it with bare hands.
When using a lifting system, such as forklifts or pallets, pay special attention to
balance and prevent tipping.
Normally, the machine should be fixed on wooden pallets to ensure safety
during transportation and storage.
Warning signs should be printed on the package to remind users to follow the
instructions and ensure the machine will not be damaged during loading,
unloading, and transportation.
Fragile Upward Do not flip Keep dry
Stacking limit
When storing or moving the machine, the maximum stack is two units, unless
otherwise specified on the label.
Since the center of gravity of the machine does not coincide with the geometric
center, be careful not to tilt the machine during handling.
Unpacking
Please use tools for unpacking the wood crate. After the unpacking, if any
damage is found, please inform the carrier immediately.
Installation
Install and place the machine securely on a stable and level surface.

6
When handling, do not push or pull the machine to avoid tipping over or
damaging the parts.
Do not place any objects on the machine, as it is open from the top.
The machine should be placed in a well-ventilated place, and away from heat
and ignition sources.
The minimum clearance ≥100mm/3.9" should be kept between the
surrounding of the machine and the wall or objects to ensure good operation
performance, ventilation and maintainability.
Before connecting to the power supply, make sure that the voltage and
frequency are consistent with the machine nameplate. A variation of +/-10% of
the normal voltage is allowed, and the machine should be connected to an
effective ground connection.
Storage
Turn off the power and unplug the machine
Empty the compartment and clean it
Keep the lid slightly open to ensure ventilation and avoid mildew or odors
Disposal
Temporary storage of special wastes may be permitted before disposal or final
disposal.
In all cases, the applicable environmental laws of the user's country must be
complied with.
Correct disposal of this product

7
This marking indicates that this product should not be
disposed of with other household wastes throughout the EU.
To prevent possible harm to the environment or human health
from uncontrolled waste disposal, recycle it responsibly to
promote the sustainable reuse of material resources. To return
your used device, please use the return and collection systems
or contact the retailer where the product was purchased. They
can take this product for environmentally safe recycling.

8
Product Structure
①
②
③
⑤
⑥
⑦
④

9
①Lid ②Control panel ③Universal wheels ④Hinge ⑤Power port
⑥Drain pipe ⑦Inlet pipe ⑧Ice mold tray ⑨Ice mold ⑩Overflow hole
⑦
+
⑧:
⑨
⑧⑩
Table of contents