VersaLogic VL-MPEu-C1E Quick user guide

Hardware
Reference
Manual
REV. April 2021
VL-MPEu-C1E
Mini PCIe CAN Module

ii VL-MPEu-C1E Hardware Reference Manual
WWW.VERSALOGIC.COM
12100 SW Tualatin Road
Tualatin, OR 97062-7341
(503) 747-2261
Fax (971) 224-4708
Copyright©2019-2021 VersaLogic Corp. All rights reserved.
Notice:
Although every effort has been made to ensure this document is error-free, VersaLogic makes no
representations or warranties with respect to this product and specifically disclaims any implied warranties of
merchantability or fitness for any particular purpose.
VersaLogic reserves the right to revise this product and associated documentation at any time without
obligation to notify anyone of such changes.
* Other names and brands may be claimed as the property of others.

VL-MPEu-C1E Hardware Reference Manual iii
Product Revision Notes
Revision 1.00 – Initial draft
Revision 1.01 – Updated Table 1 with additional J1 part descriptions
Support
The VL-MPEu-C1E product page contains additional information and resources for this product including:
•Reference Manual (PDF format)
•Device drivers
•Data sheets and manufacturers’ links for chips used in this product
•Photograph of the circuit board
This is a private page for VL-MPEu-C1E users that can be accessed only by entering this address directly. It
cannot be reached from the VersaLogic homepage.

iv VL-MPEu-C1E Hardware Reference Manual
Contents
Introduction .....................................................................................................................5
Description.......................................................................................................................... 5
Features and Construction ..................................................................................... 5
Technical Specifications ........................................................................................ 5
Block Diagram.................................................................................................................... 6
RoHS Compliance .............................................................................................................. 7
About RoHS........................................................................................................... 7
Warnings............................................................................................................................. 7
Electrostatic Discharge .......................................................................................... 7
Handling Care........................................................................................................ 7
Technical Support ............................................................................................................... 8
Repair Service........................................................................................................ 8
Physical Details...............................................................................................................9
Board Layout and Mounting............................................................................................... 9
VL-MPEu-C1E Mounting ..................................................................................... 9
VL-MPEu-C1E Dimensions and Connectors ........................................................ 9
CAN Termination Jumpers .................................................................................. 10
Interfaces and Connectors...........................................................................................11
CAN Connector (J1) ......................................................................................................... 11
PCIe Minicard Connector ................................................................................................. 11
LEDS ................................................................................................................................ 12

VL-MPEu-C1E Hardware Reference Manual 5
Introduction
Description
FEATURES AND CONSTRUCTION
The VL-MPEu-C1E is an extremely small and rugged module designed to connect to a Controller
Area Network. This industry-standard Mini PCIe module provides an easy and economical way
to add a twin CAN FD interface to an embedded computer system. The module is also backward
compatible with CAN 2.0 A and CAN 2.0 B protocols.
The VL-MPEu-C1E supports two CAN channels using a 2 mm 6-pin Molex MicroClasp
connector for a secure connection. Accessory cables are available for conversion to other
connector types.
The module features a wide operating temperature range (-40° to +85°C) and it is designed to be
rugged and robust for use in industrial and military applications.
The VL-MPEu-C1E supports a wide range of CAN functionality including: message acceptance
filter and listen-only mode. The module supports the CANopen higher layer protocol.
The VL-MPEu-C1E module is compatible with a variety of popular operating systems including
Windows and Linux.
TECHNICAL SPECIFICATIONS
Specifications are subject to change without notification.
General Specifications
Board Size: 30 mm x 52.55 mm x 10.18 mm
Storage Temperature: -40° to +85°C
Operating Temperature: -40° to +85°C
Power Requirements: … 3.3V @ 66mA (0.22W)
Software: Compatible with most x86 operating systems
including Windows*, Windows Embedded, and Linux
CAN Interface: 2 channels, supporting CAN-FD or CAN
2.0 networks.
•Galvanically isolated (2.5 kV rated).
•ISO11898 compliant.
Mini PCIe Signal Type: PCI Express Gen 1 and Gen 2
Signaling: Supports 11-bit as well as 29-bit identifiers.
CAN 2.0B – Support baud rate:
•100/125/250/500(default)/800/1000K.
•CAN-FD – Support above baud rates and up to
CAN-FD max (5 Mbps)
11

Introduction
6VL-MPEu-C1E Hardware Reference Manual
Block Diagram

Introduction
VL-MPEu-C1E Hardware Reference Manual 7
RoHS Compliance
The VL-MPEu-C1E is RoHS-compliant.
ABOUT ROHS
In 2003, the European Union issued Directive 2002/95/EC regarding the Restriction of the use of
certain Hazardous Substances (RoHS) in electrical and electronic equipment.
The RoHS directive requires producers of electrical and electronic equipment to reduce to
acceptable levels the presence of six environmentally sensitive substances: lead, mercury,
cadmium, hexavalent chromium, and the presence of polybrominated biphenyls (PBB) and
polybrominated diphenyl ethers (PBDE) flame-retardants, in certain electrical and electronic
products sold in the European Union (EU) beginning July 1, 2006.
VersaLogic Corp. is committed to supporting customers with high-quality products and services
meeting the European Union’s RoHS directive.
Warnings
ELECTROSTATIC DISCHARGE
Warning! Electrostatic discharge (ESD) can damage circuit boards, disk drives, and other
components. The circuit board must only be handled at an ESD workstation. If an
approved station is not available, some measure of protection can be provided by
wearing a grounded antistatic wrist strap. Keep all plastic away from the board, and
do not slide the board over any surface.
After removing the board from its protective wrapper, place the board on a
grounded, static-free surface, component side up. Use an antistatic foam pad if
available.
The board should also be protected inside a closed metallic antistatic envelope
during shipment or storage.
Note: The exterior coating on some metallic antistatic bags is sufficiently conductive to
cause excessive battery drain if the bag comes in contact with the bottom side of
the board.
HANDLING CARE
Warning! Care must be taken when handling the board not to touch the exposed circuitry
with your fingers.

Introduction
8VL-MPEu-C1E Hardware Reference Manual
Technical Support
If you are unable to solve a problem after reading this manual, please visit the VL-MPEu-C1E
product page. This page provides links to component datasheets and device drivers.
If you have further questions, contact VersaLogic Technical Support at (503) 747-2261.
VersaLogic support engineers are also available via e-mail at Support@VersaLogic.com.
REPAIR SERVICE
If your product requires service, you must obtain a Returned Material Authorization (RMA)
number by calling (503) 747-2261. Please provide the following information:
•Your name, the name of your company, your phone number, and e-mail address
•The name of a technician or engineer that can be contacted if any questions arise
•Quantity of items being returned
•The model and serial number (barcode) of each item
•A detailed description of the problem
•Steps you have taken to resolve or recreate the problem
•The return shipping address
Warranty Repair All parts and labor charges are covered, including return shipping
charges for UPS Ground delivery to United States addresses.
Non-warranty Repair All approved non-warranty repairs are subject to diagnosis and labor
charges, parts charges, and return shipping fees. Please specify the
shipping method you prefer and provide a purchase order number for
invoicing the repair.
Note: Please mark the RMA number clearly on the outside of the box before
returning.

VL-MPEu-C1E Hardware Reference Manual 9
Physical Details
Board Layout and Mounting
VL-MPEU-C1E MOUNTING
Note: Be careful not to over tighten the nylon mounting screws. Optimum tightness is 1 lbf·in
(0.1 N·m).
VL-MPEU-C1E DIMENSIONS AND CONNECTORS
Figure 1. VL-MPEu-C1E Dimensions and Connectors
(Not to scale. All dimensions in millimeters.)
22

System Features
10 VL-MPEu-C1E Hardware Reference Manual
The table below provides information about the function, mating connectors, and transition cables
for VL-MPEu-C1E connectors.
Table 1: Connector Functions and Interface Cables
Connector Function Transition Cable Cable Description
J1
CAN Port
VL-CBR-0603 (Molex 51065-
0600)
CAN bus cable, two channels, 2 mm 6-
pin MicroClasp to 2x DB9 connector,
0.5 m
Note: J1 header part number = Molex 53254-0670
CAN TERMINATION JUMPERS
Two 2mm jumpers are required per CAN interface due to the split termination (V1 dual jumper
for CAN Port 0 and V2 dual-jumper for CAN Port 1). The jumpers are installed to enable split-
termination. The following are the jumper states for the V1 positions on Port 0 and V2 jumper on
Port 1.
Table 2: CAN Termination Jumpers (CAN Port 0)
Jumper Block(s) Description
V1[1-3] and V1[2-4]
Split Termination (both must be installed)
V1[1-2]
Non-Split Termination
V1[3-4]
Holding Position only (no function)
No Jumpers No termination
Table 3: CAN Termination Jumpers (CAN Port 1)
Jumper Block(s)
Description
V2[1-3] and V2[2-4]
Split Termination (both must be installed)
V2[1-2]
Non-Split Termination
V2[3-4]
Holding Position only (no function)
No Jumpers
No termination
Note: The jumpers can be removed and bypassed (using 0-ohm 0402 resistors) for jumper-less
operation. The split termination capacitor can be removed if split-termination is not desired.
Table of contents
Other VersaLogic Control Unit manuals
Popular Control Unit manuals by other brands

Festo
Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation
JS Automation MPC3034A user manual

JAUDT
JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum
Spektrum Air Module System manual

BOC Edwards
BOC Edwards Q Series instruction manual

KHADAS
KHADAS BT Magic quick start

Etherma
Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations
PMFoundations Attenuverter Assembly guide

GEA
GEA VARIVENT Operating instruction

Walther Systemtechnik
Walther Systemtechnik VMS-05 Assembly instructions

Altronix
Altronix LINQ8PD Installation and programming manual









