V-Show B198 User manual

1
LED 198 module Beam Moving Head
User Manual

2
1.Safety Instructions
Please read the instruction carefully which includes important
information about the installation, usage and maintenance.
Please keep this User Guide for future consultation. If you sell the unit to
another user, be sure that they also receive this instruction manual.
Important:
Damages caused by the disregard of this user manual are not subject to
warranty. The dealer will not accept liability for any resulting defects or
problems.
Unpack and check carefully to ensure that there is no transportation damage
before using the unit.
This product is for indoor use only. Use only in a dry location.
DO install and operate by qualified operator.
DO NOT allow children to operate the fixture.
Use safety chain when fixing the unit. Handle the unit by carrying its base
instead of head only.
The unit must be installed in a location with adequate ventilation, at least 50cm
from adjacent surfaces.
Be sure that no ventilation slots is blocked, otherwise the unit will be
overheated.
Before operation, ensure that you are connecting this product to the proper
voltage in accordance with the specifications in this manual or on the product’s
specification label.
It’s important to ground the yellow/green conductor to earth in order to avoid
electric shock.
Minimum ambient temperature TA: 0℃. Maximum ambient temperature TA:
40℃. Do not operate this product at a lower or higher temperature.
DO NOT connect the device to any dimmer pack.
Avoid any flammable liquids, water or metal from entering the unit. Once it
happens, cut off the mains power immediately.
DO NOT operate in a dirty or dusty environment. DO clean the fixture regularly.
DO NOT touch any wire during operation as there might be a hazard of electric
shock.
Avoid entanglement of the power cord with other wires.
The minimum distance to objects/surface must be more than 1 meters.
Disconnect mains power before fuse/lamp replacement or servicing.

3
Replace fuse/lamp only with the same type.
In the event of serious operating problem, stop using the unit immediately.
Never turn on and off the unit time after time.
The housing, the lenses, or the ultraviolet filter must be replaced if they are
visibly damaged.
DO NOT attempt to operate this unit if it becomes damaged. DO NOT attempt
any repairs
yourself. Repairs carried out by unskilled people can lead to damage or
malfunction. Please contact the nearest authorized technical assistance center
if needed.
Disconnect this product from its power source before servicing.
DO use the original packaging if the device is to be transported.
Avoid direct eye exposure to the light source while the product is on.
Never touch bulb with bare fingers, as it is very hot after using.
DO NOT operate this product if you see damage on the housing, shields, or
cables. Have the damaged parts replaced by an authorized technician at once
Installation:
The fixture should be fixed on the clamp. Always ensure that the unit is firmly
fixed to avoid vibration and slipping off during operation. Ensure that the
trussing or area of installation must be able to hold 10 times the weight without
any deformation. Always install a safety cable that can hold at least 12 times
the weight of the fixture when installing.DO install and operate by qualified
operator. It must be installed in a place where there is out of the reach of
people.
2.INSTALLATIONS
installations Note: In order to increase protection, please install the lamp on
the sidewalk, outside the seating area, or an area where unauthorized persons
may touch the lamp
Before installing the fixture on any surface, make sure that the installation area
can bear the minimum point load above 10 points of the weight of the
equipment. The installation of the fixing device must always be fixed with
auxiliary safety accessories (such as a suitable safety rope)
Do not stand directly under the equipment when installing, removing, or
servicing fixtures
From the ceiling or set on a flat surface (see the picture below). Ensure that
this fixture is kept at least 0.5m (1.5 feet) away from any flammable materials
(decorations, etc.)
Be sure to use and install the supplied safety rope to ensure safety and

4
prevent accidental damage and/or injury in case the fixture is damaged
Installation point: Overhead installation requires a wealth of experience,
including calculation of working load limits, in-depth understanding of the
installation materials used, and regular safety inspections of all installation
materials and fixtures. If you do not have these qualifications, please do not try
to install it yourself. Improper installation can cause personal injury
Before connecting the main power cord to an appropriate wall outlet, make
sure to complete all assembly and installation procedures
Lamp installation: LED shaking head provides a unique mounting bracket
assembly, which integrates the bottom of the base and the fixing point of the
safety cable into one unit (see the figure below). When installing the fixture to
the truss, make sure to use the appropriate tools to fix it on the attached
bracket, and use the M10 screw that passes through the center hole of the
"bracket" to fix it. As an additional safety measure, make sure to use at least
one safety cable integrated in the base assembly to connect at least one
appropriately rated safety cable to the fixture.
3. DMX-512 control connections
Connect the provided XLR cable to the female 3-pin XLR output of your
controller and the other side to the male 3-pin XLR input of the moving head.
You can chain multiple
Moving heads be connected together through serial linking. The cable needed
should be two core, screened cable with XLR input and output connectors.
For installations where the DMX cable has to run a long distance or is in an
electrically noisy environment, such as in a discotheque, it is recommended to
use a DMX terminator. This helps in preventing corruption of the digital control
signal by electrical noise. The DMX terminator is simply an XLR plug with a 120
Ω resistor connected between pins 2 and 3,which is then plugged into the
output XLR socket of the last fixture in the chain. Please see illustrations below

5
1
2
3
PIN 3
PIN 2
120Ω
4.Address code setting
If you use a universal DMX controller to control the units, you have to set DMX
address from 1 to 512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select DMX Settings, press the
ENTER button to confirm, use the UP/DOWN button to select DMX Address,
press the ENTER button to confirm, the present address will blink in the display,
use the UP/DOWN button to adjust the address from 001 to 512, press the
ENTER button to store. Press the MENU button back to the last menu or let the
unit idle 30 seconds to exit menu mode.Please refer to the following diagram to
address your DMX512 channel for the first 4 units.
Channel
MODE
UNIT1
ADDERSS
UNIT2
ADDERSS
UNIT3
ADDERSS
UNIT4
ADDERSS
17CH
1
18
35
52

6
5. Fixture size
6. Illuminance chart:

7
7. Effect Wheels
Color wheels
Gobo wheels
Colorful

8
8.Product parameter introduction
Input voltage: AC100-240V 50-60HZ
Output Voltage: V1:36V(Master board+LED driver), V2:12V(cooling fan+Display)
Power supply: 250W
Light source: 198W module high output white light LED
Light strip: 30pcs 0.5W RGB5050LED
Service life: 50,000 hours service life, low power consumption
Color temperature: 7500K
Beam angle: 1.3° beam angle, focusing function
Color: 10 colors + white, variable direction and speed
Fixed gobos: 18 fixed gobos + white light, rotation and jitter
Prism: 16 prism, variable speed bidirectional rotation
With fog and colorful function
Strobe: high-speed strobe effect, 1-25 flashes per second
Channel: 17 CH
Control mode: DMX 512, master-slave, voice control, self-propelled
With remote RDM function
Auto focus function
Display mode: color liquid crystal display
Horizontal scan: 540 degrees (160bit precision scan) electronic error correction.
Vertical scanning: 270 degrees (160bit precision scanning) electronic error correction.
Temperature protection function, when the internal temperature reaches 40℃, the fan
starts to work, when the internal temperature reaches 70℃and the brightness is reduced
by half.
Features:
The appearance of the product is simple and exquisite, light weight, suitable for use in
multiple places, using high-brightness LED module light source, the light is sharp and the
spot is clear, using a two-in-one high-precision lens, the minimum light-emitting angle
reaches 1.3 degrees, a variety of stroboscopic effects, equipped with Atomization and
colorful functions, high standard constant current solution, strong uniformity of low
brightness, stable linear dimming, auto focus function, support RMD remote dialing
function, the light strip is equipped with 20 static effects and 51 dynamic effects. When
dialing the address code, press the up button in the menu to automatically increase the
number of channels, without calculating the address code of the next lamp, the lamp
automatically monitors the photocoupler and Hall data function, and has a temperature
self-check function, the lamp temperature reaches 40 degrees, the fan starts, The power
is reduced to 70 degrees to protect the life of the lamp beads.

9
9.Menu top interface
Address: Click to enter the address code setting
Settings: Click to enter the system settings
Manual: Click to enter manual mode
Calibration: Click to enter the password to enter the system calibration mode
Reset: Click to enter the system reset mode
Information: Click to enter to view system information
10.Menu structure
Main menu
Secondary menu
Three-level menu/parameter
address
001-512
(Add the number of channels each time,
subtract the normal)
System
settings
Operating mode
DMX/sound control/self-propelled
1/self-propelled 2
Channel mode
17CH
Horizontal reversal
switch
Vertical reverse
switch
Hall error correction
switch
Optocoupler error
correction
switch
Signal hold
switch
screen protector
switch
Screen flip
On/off/auto
Synchronization
Update
switch
Language
Medium/EN
reset
Manual mode
Color wheel
000-255
Strobe
000-255
Dimming
000-255

10
Picture plate
000-255
Reserved
000-255
Reserved
000-255
Atomization
000-255
focusing
000-255
X axis
000-255
X-axis fine
adjustment
000-255
Y axis
000-255
Y-axis fine
adjustment
000-255
Reserved
000-255
Reset
000-255
Reserved
000-255
Reserved
000-255
Reserved
000-255
Reserved
000-255
Reserved
000-255
System
calibration
X axis motor
000-255
Y axis motor
000-255
Color wheel motor
000-255
Pattern motor
000-255
Reserved motor
000-255
Focus motor
000-255
Atomization motor
000-255
power
010-255
MIC sensitivity
000-255
change Password
Enter a new password
System reset
Effect motor reset
Scan motor reset
All motors reset
system
message
Reset information
Display specific information content
DMX data detection
Display specific DMX detection
content
Sensor information
Display specific information of
optocoupler and Hall
hardware version
Software version
Other V-Show Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Qazqa
Qazqa Suplux SL 3 Black 103062 instruction manual

Commercial Electric
Commercial Electric 54568141 Use and care guide

CREE LIGHTING
CREE LIGHTING 304 Series installation instructions

Goobay
Goobay 49867 user manual

ECOMAN ITALIA
ECOMAN ITALIA LED T8 instruction manual

Alkalite
Alkalite Krypton KT-81 user manual