Unit UTG4000A User manual

UTG4000A
Function/Arbitrary
Waveform Generator
Quick Guide

UTG4000A Operating Manual
Introduction
Dear Users:
Hello! Thank you for choosing this brand new UNI-T device. In order to safely and
correctly use this instrument, please read this manual thoroughly, especially the Safety
Notes part.
After reading this manual, it is recommended to keep the manual at an easily
accessible place, preferably close to the device, for future reference.
1

UTG4000A Operating Manual
Copyright Information
● UNl-T Uni-Trend Technology (China) Limited. All rights reserved.
Trademark Information
● UNI-T is the registered trademark of Uni-Trend Technology (China) Limited.
Document Version
UTG4000A-20160618-EN-V1.2
Statement
● UNI-T products are protected by patent rights in China and foreign countries,
including issued and pending patents.
● UNI-T reserves the rights to any product specification and pricing changes.
● UNI-T reserves all rights. Licensed software products are properties of Uni-Trend and
its subsidiaries or suppliers, which are protected by national copyright laws and international
treaty provisions.
● Information in this manual supercedes all previously published versions.
2

UTG4000A Operating Manual
Warranty
UNI-T warrants that the product will be free from defects for a three-year period. If the
product is re-sold, the warranty period will be from the date of the original purchase from an
authorized UNI-T distributor. Probes, other accessories, and fuses are not included in this
warranty.
If the product is proved to be defective within the warranty period, UNI-T reserves the
rights to either repair the defective product without charging of parts and labor, or exchange
the defected product to a working equivalent product. Replacement parts and products may
be brand new, or perform at the same specifications as brand new products. All replacement
parts, modules, and products become the property of UNI-T.
The “customer” refers to the individual or entity that is declared in the guarantee. In order to
obtain the warranty service, "customer" must inform the defects within the applicable warranty
period to UNI-T, and to perform appropriate arrangements for the warranty service. The customer
shall be responsible for packing and shipping the defective products to the designated maintenance
center of UNI-T, pay the shipping cost, and provide a copy of the purchase receipt of the original
purchaser. If the product is shipped domestically to the location of the UNI-T service center,
UNI-T shall pay the return shipping fee. If the product is sent to any other location, the customer
shall be responsible for all shipping, duties, taxes, and any other expenses.
This warranty shall not apply to any defects or damages caused by accidental, machine
parts’ wear and tear, improper use, and improper or lack of maintenance. UNI-T under the
provisions of this warranty has no obligation to provide the following services:
a) Any repair damage caused by the installation, repair, or maintenance of the product
by non UNI-T service representatives.
b) Any repair damage caused by improper use or connection to an incompatible device.
c) Any damage or malfunction caused by the use of a power source which does not
conform to the requirements of this manual.
d) Any maintenance on altered or integrated products (if such alteration or integration
leads to an increase in time or difficulty of product maintenance).
This warranty written by UNI-T for this product, and it is used to substitute any other
express or implied warranties. UNI-T and its distributors do not offer any implied warranties
for merchantability or applicability purposes.
For violation of this guarantee, UNI-T is responsible for the repair or replacement of
defective products is the only remedy available to customers. Regardless of whether UNI-T and
its distributors are informed that any indirect, special, incidental, or consequential damage may
occur, the UNI-T and its distributors shall not be responsible for any of the damages.
3

UTG4000A Operating Manual
Table of Contents
Chapter 1 Safety Information -------------------------------------------------------------------------5
1.1 Safety Terms and Symbols ----------------------------------------------------------------5
1.2 General Safety Overview ----------------------------------------------------------------6
Chapter 2 Quick Start -----------------------------------------------------------------------------------7
2.1 General Inspection---------------------------------------------------------------------------7
2.1.1 Inspect Whether Damage is Caused by Transportation -------------------7
2.1.2 Inspect Accessories ----------------------------------------------------------------7
2.1.3 Inspect Complete Machine -------------------------------------------------------7
2.2.1 Introduction of Panels and Keys -------------------------------------------------7
2.2.2 Front Panel --------------------------------------------------------------------------7
2.2.3 Function Interface -------------------------------------------------------------------8
2.2.4 Back Panel ----------------------------------------------------------------------------9
2.3.1 Output Basic Waveform -----------------------------------------------------------9
2.3.2 Set Output Frequency -------------------------------------------------------------9
2.3.3 Set Output Amplitude -------------------------------------------------------------10
2.3.4 Set DC Offset Voltage ------------------------------------------------------------11
2.3.5 Set Pulse Wave --------------------------------------------------------------------12
2.4 Frequency Measurement ----------------------------------------------------------------13
Chapter 3 Advanced Applications ------------------------------------------------------------------14
3.1 Output Modulation Waveform-----------------------------------------------------------14
3.2 Output Arbitrary Wave --------------------------------------------------------------------23
3.2.1 Use Arbitrary Wave Function ---------------------------------------------------23
3.2.2 Point-by-point Output/Play Mode ----------------------------------------------23
3.2.3 Select Arbitrary Wave ------------------------------------------------------------24
3.2.4 Create and Edit Arbitrary Waveform ------------------------------------------24
3.2.5 Output Digital Protocol Coding -------------------------------------------------24
3.3 Function of Digital Arbitrary Wave -----------------------------------------------------35
Chapter 4 Fault Handling -----------------------------------------------------------------------------42
4.1 No Display on Screen (Blank Screen) -------------------------------------------------42
4.2 No Waveform Output ---------------------------------------------------------------------42
4.3 Fail to Correctly Recognize U Disk ----------------------------------------------------42
4

UTG4000A Operating Manual
Chapter 1 Safety Information
1.1 Safety Terms and Symbols
The following terms may appear in this quick guide:
Warning: The conditions and behaviors may endanger life.
Caution: The conditions and behaviors may cause damage to the product and other
properties.
The following terms may appear on the product:
Danger: Performing this operation may cause immediate damage to the operator.
Warning: This operation may cause potential damage to the operator.
Caution: This operation may cause damage to the product and devices connected to
the product.
The following symbols may appear on the product:
AC Electricity
Measurement ground terminal
Housing ground terminal
ON/OFF
High voltage hazard
Caution: please refer to the manual
Protective ground terminal
CE is registered trademark of EU
C-tick is registered trademark of Spectrum Management Agency of Australia.
It indicates conformity with provisions of Australian EMC Framework formulated
according to terms of Wireless Communication Act in 1992.
Containing at least one of six harmful substances that exceed maximum
concentration value (MCV) and environment-friendly usage period (EPUP) of 40
years.
5

UTG4000A Operating Manual
1.2 General Safety Overview
This instrument is designed and produced in strict accordance with GB4793 Safety
Requirements for Electronic Measuring Apparatus and IEC61010-1 safety standard, up to
insulation and overvoltage standard CAT II 300V and safety standard for level-II pollution.
Please read the following preventive safety measures:
● In order to prevent electric shock or fire, please use power line and adapter
dedicated to this product and approved by the country.
● This product is grounded through protective ground lead in the power line. In order
to prevent electric shock, please check whether the power socket to be used for the product
is grounded. Please ensure that the protective ground terminal of the product is reliably
connected to the ground terminal of power line before connecting any input or output terminal
other than power line.
● To avoid personal injury and prevent damage to the product or any product
connected to the product. In order to avoid possible danger, the product can only be used in
the specified scope. Only personnel that have received professional training can execute
maintenance procedures.
● In order to prevent fire or electric shock, please pay attention to all rated values and
signs of the product. Please read the user manual to further understand information about
rated value.
● Don’t use input voltage above rated value of the instrument.
● Inspect whether accessories suffer from mechanical damage before use. If so,
please replace them.
● Only accessories provided for the product can be used. Please don’t use
accessories that are damaged.
● Don’t insert metal objects into input or output terminal of the product.
● If you suspect the product is damaged, please ask qualified maintenance
personnel for inspection.
● Please don’t put the product into operation when crate is opened.
● Please don’t operate in humid environment.
● Please don’t operate in inflammable and explosive environment.
● Keep the surface of product clean and dry.
6

UTG4000A Operating Manual
Chapter 2 Quick Start
2.1 General Inspection
When you get a new function/arbitrary waveform generator, you are advised to inspect
the instrument according to the following steps.
2.1.1 Inspect Whether Damage is Caused by Transportation
If the packaging box or foamed plastic supplementary mat is seriously damaged, please
contact with dealer of the product or local office.
If the instrument is damaged during transportation, please keep the package, and notify
transportation department and dealer of the product, who will arrange repair or replacement.
2.1.2 Inspect Accessories
UTG4000A accessories include power line (applicable to the destination country/region), a
USB data transmission line, two BNC cables (1m), a user CD and a product warranty card.
In case of lack or damage of accessories, please contact with dealer of the product or
local office.
2.1.3 Inspect Complete Machine
If appearance of the instrument is damaged, the instrument runs abnormally or fails to
pass performance test, please contact with dealer of the product or local office.
2.2.1 Introduction of Panels and Keys
2.2.2 Front Panel
Function/arbitrary waveform generator of UTG4000A series provides users with simple
and intuitive front panel that is easy to operate, which is shown in figure 2-1 below:
7

UTG4000A Operating Manual
2.2.3 Function Interface
Function interface is shown in Figure 2-2:
Figure 2-1 Structure of front panel
ype
Figure 2- 2 Function interface
Waveform
parameter
list
Waveform
display
area
Soft
key
labels
8

UTG4000A Operating Manual
2.2.4 Back Panel
Back panel is shown in Figure 2-3:
2.3.1 Output Basic Waveform
2.3.2 Set Output Frequency
The default configuration of waveform is a sine wave with frequency of 1kHz and
peak-to-peak amplitude of 100mV (terminating at 50Ω) when powering on. One example for
changing frequency into 2.5MHz are as follows:
1. Press function key F1, when outline border in the display area is the color of
corresponding channel, and “Freq” character is white, “Period” tag is gray. If the current
frequency value is valid, the same frequency is used. Please press function key F1 again to
change to the set waveform period, when “Freq” character turns gray, “Period” character is
highlighted, and frequency and period can be switched.
Figure 2-3 Structure of back panel
9
This manual suits for next models
3
Table of contents
Other Unit Portable Generator manuals

Unit
Unit UTG900E Series User manual

Unit
Unit UTG2122B User manual

Unit
Unit UTG1000X Series User manual

Unit
Unit UTG9000C-II Series User manual

Unit
Unit UTG1000 Series User manual

Unit
Unit UTG1000X Series User manual

Unit
Unit UTG2025A User manual

Unit
Unit UTG9504T User manual

Unit
Unit UTG9000T Series User manual