UfiSpace S9705-48D Manual

Hardware Installation Guide
S9705-48D
Core/Edge Router
R1.0

S9705-48D Hardware Installation Guide | i
Table of Contents
1Overview............................................................................................................................... 1
2Preparation...........................................................................................................................2
Installation Tools......................................................................................................................2
Installation Environment Requirements .................................................................................3
Preparation Check List.............................................................................................................4
3Package Contents..................................................................................................................5
Accessory List...........................................................................................................................5
Component Physical Information............................................................................................6
4Identifying Your System ........................................................................................................7
S9705-48D Overview ...............................................................................................................7
PSU Overview...........................................................................................................................7
Fan Overview ...........................................................................................................................8
Port Overview ..........................................................................................................................9
5Rack Mounting.................................................................................................................... 10
6Installing Fan Modules ........................................................................................................ 13
7Installing Power Supply Units.............................................................................................. 14
8Grounding the Router ......................................................................................................... 16
9Connecting Power............................................................................................................... 18
DC Version .............................................................................................................................18
AC Version..............................................................................................................................20
10 Verifying System Operation ................................................................................................ 22
Front Panel LED....................................................................................................................22
PSU FRU LED ........................................................................................................................23
Fan FRU LED.........................................................................................................................23
11 Initial System Setup ............................................................................................................ 24
12 Cable Connections............................................................................................................... 25
Connecting the USB Extender Cable....................................................................................25
Connecting the Transceiver.................................................................................................25
13 Cautions and Regulatory Compliance Statements ............................................................... 27
Cautions and Regulatory Compliances................................................................................27

S9705-48D Hardware Installation Guide | 1
1Overview
The UfiSpace S9705-48D enables the disaggregated architecture required to fulfill the high
traffic loading in a 5G mobile Ethernet network. As part of UfiSpace’s S9700 Series, the
S9705-48D is a robust fabric switch that used to interconnect the S9710-76D, S9700-53DX
and/or S9700-23D routers into pay-as-you-grow cluster sizes. Suitable for core networking,
the S9705-48D is one of the essential building blocks to provide carriers with a better
solution in place of the traditional chassis.
With redundant power supplies and fans together with a high port density design, our
S9705-48D delivers high system reliability, switching performance and intelligence to the
network and helps reduce infrastructure and administrative costs.
This document describes the technical specifications designed for S9705-48D.

S9705-48D Hardware Installation Guide | 2
2Preparation
Installation Tools
Phillips #2 Screw Driver
6-AWG green-and-yellow wire for grounding
Crimping tool
Wire stripping tool
All illustrations within this document are for reference purposes only. Actual
objects may differ.
•PC with terminal emulation software. Refer to the "Initial System Setup" section for
details.
•Baud rate: 115200 bps
•Data bits: 8
•Parity: None
•Stop bits: 1
•Flow control: None

S9705-48D Hardware Installation Guide | 3
Installation Environment Requirements
•Power Reserve: The S9705-48D power supply is available with:
1. DC Version: 1+1 Redundant and hot swappable, active/active -48V voltage DC power supply
field replaceable unit or;
2. AC Version: 1+1 Redundant and hot swappable, active/active 200V to 240V AC power
supply field replaceable unit.
To ensure the redundant, active/active feed power design functions properly, a field with
dual power circuit is recommended with a reserve of at least 1500 watts on each power
circuit.
•Space Clearance: The S9705-48D chassis width is 17.16 inches (43.6cm) and is shipped with an
adjustable mounting rail kit suited for standard 19 inch (48.3cm) wide racks. The depth of the
S9705-48D chassis is 30 inches (76.2cm) without the field replaceable units (FRUs). The handle
of fan FRU is 1 inch (2.5cm) and the handle of the PSU FRU is 1.5 inches (3.8cm). Therefore, to
accommodate the fan, power supply handles, airflow and cabling, a minimum space
clearance of 6 inches (15.2cm) is needed at front and back of the S9705-48D. A total
minimum reserve depth of 42 inches (106.6cm) is required.
Figure 1.
•
Cooling: The S9705-48D airflow direction is front-to-back. Make sure the equipment on
the same rack have the same airflow direction.
Figure 2.

S9705-48D Hardware Installation Guide | 4
Figure 3.
Preparation Check List
Task
Check
Date
Power voltage and electric current requirement
DC version: -40 to -72V DC, 60 to 33 x 2 ampere maximum or;
AC version: 200 to 240V AC, 12.5 x 2 ampere maximum
Installation spacing requirement
S9705-48D chassis spacing requires a height of 2RU (3.45”/8.8cm), a
width of 19” (48.3cm), and a depth of 42 inches (106.6cm)
Thermal requirement
S9705-48D working temperature is 0°C to 45°C (32°F to 113°F),
airflow direction is front-to-back
Installation tools required
#2 Philips screwdriver, wire-stripping tools for stripping 6-AWG,
crimping tool for ground lug
Accessories required
PC with USB ports and terminal emulation software

S9705-48D Hardware Installation Guide | 5
3Package Contents
Accessory List
Item
Description
Spec. & Dimensions
Qty.
Weight
1
Grounding Lug
DC Version:
1.54” x 1.47” x 0.49”
(# 6 AWG)
(39 x 37.5 x 12.5mm)
5 pcs
0.14lbs (63.6g)/5 pcs
AC Version:
1.54” x 1.47” x 0.49”
(# 6 AWG)
(39 x 37.5 x 12.5mm)
1 pcs
0.03lbs (15.3g)/1 pcs
2
Screw Kit (for
Grounding Lug)
2 x Screw M4*L8.0mm
2 x M4 Lock Washers
2 sets
0.01lbs (2.6g)/1 set
3
Micro USB Cable
3.28’ (1m)
1 pcs
0.05lbs (24.4g)/1 pcs
4
RJ45 to DB9 Female
Cable
8’ (2.4m)
1 pcs
0.23lbs (105g)/1 pcs
5
Adjustable Mounting
Rail (for 4 post)
30.4” x 1.7” x 0.9”
(771 x 44 x 22mm)
(22”~33” rack depth)
2 pcs
7.01lbs (3.2kg)/2 pcs
(3.5lbs (1.6kg)/1 pcs)
6
Screw Kit
(for Rack Mount Rail)
2 x Screw M4.0*L5.5mm
2 sets
0.004lbs (1.9g)/1 set

S9705-48D Hardware Installation Guide | 6
Component Physical Information
Specification
Item
Description
Weight
Total package contents
54.89lbs (24.9kg)
Chassis without FRU
45.19lbs (20.5kg)
Power Supply Unit (PSU)
DC PSU: 2.65lbs (1.2kg)
AC PSU: 2.65lbs (1.2kg)
Fan module
1.10lbs (498g)
Ground lug
0.15lbs (66.2g)
Adjustable mounting rail
7.05lbs (3.2kg)
Micro USB cable
0.05lbs (24.4g)
RJ45 to DB9 Female cable
0.23lbs (105g)
AC power cord (AC version only)
0.70lbs (318g)
Dimension
S9705-48D (W x D x H)
17.16” x 30” x 3.45” (436 x 762 x 87.7mm)
PSU (W x D x H)
1.99 x 14.17” x 1.58” (50.5 x 360 x 40mm)
Fan (W x D x H)
3.15” x 4.80” x 3.15” (80 x 122 x 80mm)

S9705-48D Hardware Installation Guide | 7
4Identifying Your System
S9705-48D Overview
Figure 4.
PSU Overview
Power supply unit (PSU) with 1+1 Redundancy. Hot swappable, field replaceable unit (FRU).
AC Version:
Figure 5.

S9705-48D Hardware Installation Guide | 8
DC Version:
Figure 6.
Fan Overview
3+1 Redundant, hot swappable, field replaceable unit (FRU).
Figure 7.
Other manuals for S9705-48D
1
This manual suits for next models
1
Table of contents
Other UfiSpace Network Router manuals

UfiSpace
UfiSpace S9705-48D Manual

UfiSpace
UfiSpace S9610-36D Manual

UfiSpace
UfiSpace S9601-104BC Manual

UfiSpace
UfiSpace S9700-23D Manual

UfiSpace
UfiSpace S9600-32X Manual

UfiSpace
UfiSpace S9600-72XC Manual

UfiSpace
UfiSpace S9600-28DX Manual

UfiSpace
UfiSpace S9600-56DX Manual

UfiSpace
UfiSpace S9600-30DX Manual

UfiSpace
UfiSpace S9701-82DC Manual