TysonBio SuperB User manual

Blood Glucose Monitoring System
For in vitro diagnostic use only
User’s Manual
Do not reuseKeep dryKeep away from sunlight
In Vitro Diagnostics Medical Device
Caution, consult accompanying documents Read Instructions for use
Store at +4ºC to +30ºC
ID:B03G106873
Revision:01
TysonBio

User’s Manual
Customer Service
If you have any questions or concerns regarding this product or its operation, or any
attempt to correct a problem fails, please call our Customer Service. Our trained
specialists will be happy to assist you, train you, or even reaffirm your results
Customer Service Hotline:
1-800-948-3894 (U.S.) (24 hours a day)
+886-37-585998
our office hours are from
8:30 am (GMT0030) - 5:30 pm (GMT0930)
or E-Mail us at
website:www.tysonbio.com
When you call our Customer Service, please have your TysonBio SUPERB Meter,
TysonBio SUPERB Test Strip and all other system supplies available. This will
allow us to answer any of your questions with speed and efficiency.

Coding Your TysonBio SUPERB Meter ............................................................23
The Control Solution Test .................................................................................25
Testing Your Blood Glucose Level ....................................................................29
Preparing the Test Strip ..............................................................................30
Obtaining a Blood Sample ..........................................................................31
Applying Blood Sample to the TysonBio SUPERB Test Strip ....................32
Memory Features ................................................................................................34
Transfer Test Results to a Computer .................................................................36
Care and Storage ................................................................................................37
Display Messages ...............................................................................................38
Specifications .....................................................................................................45
Limitations of the Procedure ......................................................................47
Service and Warranty .........................................................................................47
Customer Service
Important Information .........................................................................................3
Introduction ..........................................................................................................7
About the Product ................................................................................................8
About the TysonBio SUPERB Meter ..........................................................9
About the TysonBio SUPERB Meter Display ............................................11
About the TysonBio SUPERB Test Strips .................................................13
About the TysonBio SUPERB Test Strip vial ............................................14
About the Glucode Chip ............................................................................15
Installing/Replacing the Battery .................................................................16
Setting Up the Meter ..........................................................................................17
Setting Up the Date, Time .........................................................................17
Setting Up the Alarm .................................................................................18
Setting Up the HI and LO Alarm ................................................................20
Enter PC Link Mode ...................................................................................21
Measure Unit and Code Setting .................................................................21
12
Table of Contents

Important Information
34
Forearm
Palm
Available Alternate Sites Testing : Palm and Forearm
TysonBio SUPERB Blood Glucose Monitoring System provides you alternate sites
testing (AST). This system provides you to test on the palm and the forearm with
the equivalent results to fingertip testing.
Alternative site results differ from fingertip results when glucose levels are chang-
ing rapidly such as after a meal, after taking insulin, during exercise, or when you
are ill or under stress.
We strongly recommend you doAST ONLY in the following intervals:
● In a pre-meal or fasting state (more than 2 hours since the last meal).
● Two hours or more after taking insulin.
● Two hours or more after exercise.
DO NOT use AST if:
● You think your blood glucose is low.
● You are unaware of hypoglycemia.
● Your AST results do not match the way you feel.
● You are testing for hyperglycemia.
● Your routine glucose results are often fluctuating.
● If you are pregnant.
There are limitations for doing AST. Please
consult your healthcare professional before
you do AST.

5 6
Physiologic differences in the circulation between the finger and other test sites
like the forearm and palm may result in differences in blood glucose measure-
ments from the other test sites and your fingertips. Changes in blood glucose
may be observed in finger blood samples sooner than blood samples from the
forearm and other alternate sites. Rub the alternate test sites about 20 seconds
before lancing. If you are testing for hypoglycemia (low blood glucose), or if you
suffer from hypoglycemia unawareness, we recommend that you test on your
fingertips.
Talk to your doctor to see if alternate site testing is right for you. With a little bit
of education, you can give your fingertips a rest and maybe test more often than
you do now. For people with diabetes, more frequent testing is a good thing.
Just remember: any time you want to be sure of an accurate, up-to-date blood
glucose reading, test on your fingertip.
1.
2.
Low or high blood glucose readings can indicate a potentially serious medical
condition. If your blood glucose reading is unusually low or high, or if you do not
feel the way your reading indicates, repeat the test with a new test strip. If your
reading is not consistent with your symptoms or if your blood glucose result is
less than 60 mg/dL (3.3 mmol/L) or higher than 240 mg/dL (13.3 mmol/L) you
should contact your healthcare professional and follow his or her treatment
advice.
Any change or administer of medication based on the TysonBio SUPERB blood
glucose test results without the consent and advice of a physician or healthcare
professional is not recommended.
Severe dehydration and excessive water loss may cause false low results. If
you believe you are suffering from severe dehydration, consult your physician
immediately.
●
●
●
CAUTION:

Your TysonBio SUPERB System is made up of several components. This booklet
is designed to guide you through the operation of the system with detailed direc-
tions and pictures. Your TysonBio SUPERB System contains:
● TysonBio SUPERB Meter
● One vial of TysonBio SUPERB Test Strips (10 strips)
● One Glucode Chip (outside the strip vial)
● One Lancing Device (Option)
● Ten Lancets (Option)
● One Control Solution
● One carrying case
● User’s Manual
● Log book (Option)
● Quick Reference Guide
Note: 25, 50 test strips vial can be purchased individually.
Thank you for choosing the TysonBio SUPERB Blood Glucose Monitoring System,
the latest advancement in biosensor technology. As you already know, Self moni-
toring of blood glucose (SMBG) is a necessary part of the treatment plan for people
with diabetes mellitus. The Diabetes Control and Complications Trial (DCCT) has
confirmed the significant benefits from SMBG when practiced as part of a larger
intensive strategy to tightly control blood glucose concentrations.
Adapted for its ease of use and quick response time, the TysonBio SUPERB
System has the ability to process accurate results utilizing only a small volume of
blood for in vitro diagnostics. The TysonBio SUPERB Blood Glucose Monitoring
System is intended for use in the home and in professional settings to monitor
whole blood glucose levels obtained from the fingertip, palm and forearm. This is
an over the counter (OTC) product.
Please read the entire User’s Manual carefully before using this product.
Introduction About the Product
7 8

Display Your test results are displayed here. The large, easy to read screen
guides you through the test by using numbers and symbols.
M Button The M(mode) button is used to set the year, month, day and time,
enters the memory mode to show the consecutive 7/14/30-day average results,
and turns the Meter on and off.
S Button The S(select/set) button is used to select year, month, day, time,
memory of results and control solution mode.
Test port This is where you insert the Test Strip into the Meter.
Battery Cover
Label
Reset Button Press this button to re-set the system.
Glucode Chip Insert the Glucode Chip for coding.
Data port Connect interface cable to transfer data.
Unit Switch Switch for mmol/L or mg/dL.1 mmol/L =18 mg/dL
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
M
S
RESET
FRONT BACK
2
4
5
7
8
3
16
9
10
About the TysonBio SUPERB Meter
910
mmol/L mg/dL
S/N:M05B13286
0537
For in vitro diagnostic use only
Manufacturer:
Tyson Bioresearch, Inc.
Chu-Nan,Taiwan
Customer Service
Call:+886-37-585998
Tyson ID:T502
Blood Glucose Meter
TysonBio

Memory Symbol Indicates in memory mode.
Temperature Message Appears if your meter is out of operating tempera-
ture range.
Battery Symbol Appears when the battery is low or must be replaced.
Blood Drop Symbol Flashes when it is ready to apply sample to Test Strip.
Warning Symbol Appears when result is out of the range of your setting
reference value.
Alarm Function Symbol Appears when the clock alarm is set.
Test Strip Symbol Appears to tell you when the meter is ready for test.
Error Symbol Appears when the strip or meter error.
Day Average Symbol Shows the average value of test results from the last
7-, 14- or 30-days.
Test Result Area Display test results.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Date
Time
Control Solution Test
Appears when doing a
control solution test and
marking the result as a
control solution test.
Units of Measurement
Unit of mmol/L or mg/dL will
appear with the test result.
Code Symbol Appears
with the code number of the
Test Strips currently in use.
1.
2.
3.
4.
5.
4
6
8
7
13
15
1
9
3
2
5
10
14
12
11
DAY AM
PM
AVG
Mem
mmol/l mg/dL
Code
H
L
About the TysonBio SUPERB Meter Display
11 12

Confirmation Window This is where you can
confirm that enough blood has been applied to the
target area.
Target Area This is where blood is drawn into the
Test Strip.
Contact Bar This end of the Test Strip is inserted
into the Test Port to activate the TysonBio SUPERB
Meter. (white side face up, Front view).
1.
2.
3.
The TysonBio SUPERB Test Strip is used to perform
the blood glucose test in conjunction with the TysonBio
SUPERB Meter.
Each strip can be used only once.
Code Number
Control Solution Range
Lot Number
Expiration Date
VIAL LABEL TEST STRIP VIAL
About the TysonBio SUPERB Test Strip About the TysonBio SUPERB Test Strip Vial
13 14
3
1
2
5-5D
Front Back
0537
Manufacturer:
Tyson Bioresearch, Inc.
5F, #22, Ke E. Road III Science-
Based Industrial Park, Chu Nan,
Taiwan Tel : +886-37-585998
Store at 4-30°C ( 39-86°F). Do not refrigerate.
Do not store test strips outside this vial.
Re-cap immediately.
WARNING:Always close lid tightly.
For testing of glucose in capillary whole blood.
For in vitro diagnostic use.
Use within 90 days after first opening.
Use
TysonBio
SUPERB
meter only !
TysonBio
AUG.2011

The Glucode Chip is used to ensure that your TysonBio SUPERB Meter provides
you with accurate results. Before performing the blood glucose test or starting a
new strip vial, please check your TysonBio SUPERB Meter with the Glucode Chip
to ensure proper performance (further instructions for use of the Glucode Chip is
provided on page 22-24).
Note:
● Always use the Glucode Chip to ensure your TysonBio SUPERB Meter is
performing properly.
● DO NOT misplace your Glucode Chip.
966 Code Number
When the battery is low, the Meter will show a warning signal.
When this display appears, it is time to replace a new battery.
When the low battery warning signal is shown, the TysonBio
SUPERB Meter will provide accurate results for approximately
50 more measurements.
From the back of the Meter, gently slide and remove the
battery cover.
Insert a 3-Volt Lithium battery (CR-2032) with the “+” side
facing up.
Slide battery cover back into place.
RWSET
1.
2.
3.
About the Glucode Chip Installing/Replacing the Battery
How to Replace the Battery
15 16
S/N:M05B13286
0537
Forin vitro diagnostic use only
Manufacturer:
TysonBioresear ch, Inc.
Chu-Nan,Taiwan
CustomerSer vice
Call:+886-37-585998
TysonID:T502
Blood Glucose Meter
TysonBio
Table of contents
Other TysonBio Blood Glucose Meter manuals

TysonBio
TysonBio AC100 User manual

TysonBio
TysonBio HS100-B User manual

TysonBio
TysonBio TB200 User manual

TysonBio
TysonBio EVOLVE User manual

TysonBio
TysonBio AC100 User manual

TysonBio
TysonBio HT100-B User manual

TysonBio
TysonBio HS200-B User manual

TysonBio
TysonBio AC500 User manual

TysonBio
TysonBio TB 100 User manual

TysonBio
TysonBio EZ Smart-608 User manual