INSTALLATION INSTRUCTIONS

Congratulaons on the purchase of your Twin Eagles Vent Hood! Our products are en-
gineered for precision and designed for style. Each Twin Eagles Vent Hood is manufac-
tured in the USA at our own state of the art facility in California.
This manual will give you easy to follow instrucons for installing, operang and main-
taining your Vent Hood. We recommend reading this manual before your rst use to
ensure safety, proper care and operaon.
At Twin Eagles, we want you to enjoy grilling and spending me together as much as we
do – making memories that linger long aer the grill cools down.
Thank you and welcome!
A SPECIAL MESSAGE TO OUR CUSTOMERS...
Dante Cantal
OWNER AND FOUNDER

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATIONS MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these instrucons for the Local Electrical Inspector’s use.
INSTALLER: Please save these Installaon Instrucons with this unit for owner.
OWNER: PLEASE READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
WARNING: CALIFORNIA PROPOSITION 65
This product can expose you to chemicals including carbon monoxide which is known to the State of California
to cause cancer and reproducve harm. To minimize exposure to the by-products of the burning fuel or from
combuson, always operate this unit according to the use and care manual and provide good venlaon. Cali-
fornia law requires businesses to warn customers of potenal exposure to such substances. For more informa-
on go to www.P65Warnings.ca.gov.
AVERTISSEMENT: PROPOSITION 65 DE L’ETAT DE LA CALIFORNIE
Cet appareil peut vous exposer aux produits chimiques et au gaz monoxyde de carbonne reconnue dans l’Etat
de la Californie pour causer le cancer et des problemes de ferlite. Pour minimiser l’exposion de ces-sous pro-
duits combusbles ou de la combuson, uliser toujours cet appareil en conformitee au manuel d’ulisaon et
d’entreen en s’assurant egalement d’une bonne venlaon. La loi de la Californie exige aux fabricants d’in-
former leurs clients aux risques d’exposion potenelle a de telles substances. Pour plus d’informaon, visiter
le site www.P65Warnings.ca.gov
CUSTOMER CARE
Please record the product informaon below and
refer to it when contacng Twin Eagles.
This informaon is found on the data nameplate,
located on the le hand inside face of the vent hood.
Remove the le most bae to visually access the data
name plate.
SERVICE INFORMATION
Model Number
Serial Number
Date of Purchase
Place of Purchase
TABLE OF CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
GETTING STARTED
ELECTRICAL REQUIREMENTS
VENT HOOD KNOCK-OUTS AND MOUNTING
LOCATIONS
TOP EXHAUST
REAR EXHAUST
MOUNTING THE TRANSITION
OUTSIDE PATIO OR LANAI INSTALLATION
BAFFLE FILTER INSTALLATION, USE, AND CARE
TEVH-C EXPLODED VIEW
TEVH-C REPLACEMENT PARTS LIST
TEVH-C WIRING DIAGRAM
WARRANTY
HOW TO OBTAIN SERVICE
1
2
3
4-5
6
7-8
8
9
10-11
12
13
14
15
17

1 | www.twineaglesgrills.com
IMPORTANT SAFETY INSTRUCTIONS:
WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unaended at high sengs. Boilovers cause smoking and greasy spillovers that
may ignite. Heat oils slowly on low or medium sengs.
B. Always turn hood ON when cooking at high heat or when ambeing food (i.e. Crepes Suzee, Cherries
Jubilee, Peppercorn Beef Flambe’)
C. Clean venlang fans frequently. Grease should not be allowed to accumulate on fan or lter.
D. Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING - TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OB-
SERVE THE FOLLOWING:
A. SMOTHER FLAMES with a close ng lid, cookie sheet, or metal tray, then turn o the burner. BE CARE-
FUL TO PREVENT BURNS. If the ames do not go out immediately, EVACUATE AND CALL THE FIRE DE-
PARTMENT.
B. NEVER PICK UP A FLAMING PAN - You may be burned.
C. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
D. Use an exnguisher ONLY if:
1. You know you have a Class ABC exnguisher, and you already know how to operate it.
2. The re is small and contained in the area where it started.
3. The re department is being called.
4. You can ght the re with your back to an exit.
Read this manual carefully and completely before using your Vent Hood to ensure proper operaon, proper
installaon, proper servicing and to reduce the risk of re, burn hazard and/ or other injury.
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. The installaon of this appliance must conform with local codes.
B. Sucient air is needed for proper venlaon of ue gases. Use metal ducng only; no smaller than 10”
diameter. Venlaon must be to the outdoors.
C. When cung or drilling into wall of ceiling, do not damage electrical wiring and other hidden ulies.
D. Before servicing or cleaning unit, unplug from GFCI outlet.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.

Twin eagles Service (562) 263-3600 | 2
Read this instrucon completely before starng installaon. Planning the complete installaon before start-
ing work is highly recommended. This includes all aspects of the installaon including hood locaon, ducng,
electrical requirements, and adequacy of mounng surfaces.
GETTING STARTED:
1. Remove all packaging materials, labels and protecve plasc lm. DO NOT LEAVE UNIT IN THE SUN WITH
PROTECTIVE PLASTIC FILM ON FOR AN EXTENDED PERIOD OF TIME AS IT WILL BECOME DIFFICULT TO RE-
MOVE.
2. Check to ensure all Vent Hood accessories listed below are included.
3. Assemble parts as per assembly instrucons.
4. Fill out Warranty Registraon Card and mail it to the indicated address, or register online. See page 17.
Vent Hood Accessories TEVH36-C TEVH48-C TEVH60-C
BAFFLE FILTER 3 4 5
CAUTION:
• To reduce the risk of re and electric shock, install this vent hood only with Integral Blower TEVI-120I.
• The hood is of sucient weight that two installers are recommended to prevent injury or damage to the
hood in handling.
• Hood is recommended for use over domesc gas or electric appliances. Not recommended for use over
solid fuel red appliances.
The vent hood is operated by a 3-speed rotary control switch located in the front le of the hood. Me-
dium to low speed will handle most exhaust requirements. Use the high-speed posion for heavy cooktop use
condions. Turn the vent hood on just before cooking to prevent the escape of discharges from the cooking
surface.
The light rotary switch is located to the right of the venlaon control.
OPERATING INSTRUCTIONS:
CLEANING AND MAINTENANCE:
CAUTION: Shut o power to unit at service entrance if you are cleaning the blower.
Use a damp cloth to wipe the outer surface of the blower. Do no use a dripping wet cloth to wipe blower. Nev-
er put your hand int the blower housing.
To clean the hood surface use only mild soap or detergent soluons. Wipe to dry surfaces using a so cloth. If
a stainless surface is being cleaned, always wipe in the direcon of the brush surface. Cleaning aids such as
“Stainless Steel Magic” are available. Never us abrasive cleaners, pads or cloth.

3 | www.twineaglesgrills.com
ELECTRICAL REQUIREMENTS:
WARNING
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of elec-
tric shock by providing an escape wire for the electrical current. This appliance is equipped with a cord having
a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and
grounded.
WARNING - Improper grounding can result in a risk of electric shock.
Consult a qualied electrician if the grounding instrucons are not completely understood, or if doubt exists as
to whether the appliance is properly grounded.
Do not use an extension cord. If the power supply cord is too short, have a qualied electrician install an outlet
near the appliance.
NOTE:
Venlator requires a dedicated 15 AMP
Power Supply.
The appliance should only be taken apart by a qualied technician, or electrical shock may occur. It is
rated at 120V, 5.4 Amps, 60Hz.
REMINDER:
Keep any electrical supply cord away from any heated features.
Unit comes with three-pronged power cord pre-installed. Vent hood must be plugged into a GFCI protected
branch circuit. Suitable for use in damp locaons when installed in a GFCI protected branch circuit.
HALOGEN LAMP WATTAGE: 40 WATTS PER LAMP

Twin eagles Service (562) 263-3600 | 4
VENT HOOD KNOCK-OUTS AND MOUNTING LOCATIONS:
FIG 1A
1
2
FOR REAR EXHAUST
FOR TOP EXHAUST
UNIT MUST BE VENTED TO THE OUTSIDE OF THE BUILDING.
! !
NOTE: The hood is of sucient weight that two installers are recommended to prevent injury or damage to the
hood in handling.
Before starng the installaon, you must idenfy if the installaon will be a rear exhaust or top exhaust instal-
laon.
Begin the installaon by removing the appropriate knock-out that will provide the top or rear exhaust point.
See FIG 1A for knock-out locaons.
CAUTION:
When knock outs are removed the edges
will be sharp!!! Sharp edges should be led
or covered with metal tape.
! !

5 | www.twineaglesgrills.com
VENT HOOD KNOCK-OUTS AND MOUNTING LOCATIONS -cont:
FIG 1B
MOUNTING HOLEMOUNTING HOLE
MOUNTING HOLEMOUNTING HOLE
X 4
MOUNTING SCREW
Installaon of the Vent Hood should also take into account the unit that the Vent Hood is to be installed above.
For best venlaon of smoke and heat, make sure the vent hoof is centered above the appliance and a min-
imum of 36 inches above the cooking surface. Refer back to the appliance manual to be sure distances and
clearances to combusble construcon are maintained.
Mounng locaons are shown in FIG 1B:
Mounng surface must be a minimum of 3/4” thick. Mount Vent Hood to desired construcon using #10
wood screws. A minimum of four #10 wood screws are needed to mount the Vent Hood. Longer screws may
be required if wall board or other nonstructural surfaces are used between the hood and the main mounng
surface. Anchors may be required if mounng screws do not engage the wood structure.
Use of furring strips to level the cabinet mounng surface may be required. Refer to FIG 2 for ducng clearanc-
es and furring strip locaons.

Twin eagles Service (562) 263-3600 | 6
TOP EXHAUST
FIG 2
BOTTOM VIEW OF CABINET
WIRING ACCESS BACK WALL
ADD FURRING STRIPS TO PROVIDE AN EVEN BOT-
TOM SURFACE FOR THE HOOD MOUNTING.
FIG 3
REMOVE KNOCK OUT # 2
ROTATE
INTO
POSITION
& SECURE
WITH 2
SCREWS
B A
10” DISCHARGE WITH TRANSITION WILL BE ON THE
CENTER LINE OF HOOD WIDTH AND ON CENTER LIE
OF 12” DIMENSION.
FIG 4
VERTICAL DISCHARGE
3”
ALL HOODS 30”
18”
12”
10” DUCT TO
DISCHARGE W/
ROOF OF WALL
CAP
TRANSITION
HOOD
WIDTH DIM A
36” 8 3/8”
48” 17 1/2”
60” 23 7/16”

7 | www.twineaglesgrills.com
REAR EXHAUST
ROTATE
INTO
POSITION
& SECURE
WITH 2
SCREWS
FIG 6
A
B
FIG 5
BOTTOM VIEW OF CABINET
ADD FURRING STRIPS TO PROVIDE AN EVEN BOT-
TOM SURFACE FOR THE HOOD MOUNTING.
WIRING ACCESS BACK WALL
FIG 7
SECURE TRANSITION TO HOOD
USING #10 SHEET METAL SCREWS.
TAPE ALL JOINTS AND SEAMS.
ROUTE TO OUTSIDE
WITH WALL CAP
TRANSITION TO 10”
DUCT OR WALL CAP
HOOD
WIDTH DIM A
36” 8 3/8”
48” 17 1/2”
60” 23 7/16”