10
MAINTENANCE
Beforeperforminganymaintenance ontheheatpump youmustturnoff thebreakerof
theelectricalsupply line.
Cleaning
Toensureoptimum performanceof theheatpump, followthese recommendations:
- Backwash the filter of the pool on a regular basis in order to ensure proper flow rate
throughthepoolheater;
-Keepthesurfaces of thecoilcleanand freeofanyobstructionsuch aspapers,leavesor
otherdebris;
- Carefully clean the unit using a soft, non abrasive and bleach free cleaner, and rinse
usingagardenhose withoutthenozzle;
- Check the drainage holes of the base of the unit to make sure that they are clean and
unobstructed. (Thispreventswaterfrom accumulatinginthe heatpump.)
Winterizing (Cupro-nickel heat exchanger)
Ifyouclosetheswimmingpoolduring thewinterseason, it isessentialtodrainthe unit in
order to prevent the formation of ice in the condenser (water section). To winterize the heat
pump,youmust:
1.Stopthe unit;
2.Shut offthebreaker ofthe heatpump electricalsupply line;
3.Disconnectthewater intletandoutlet connections (See “WaterDeviation”for details.);
4.Freelyflush thecondenser withtapwater.Completely drainthesystem usingair pres-
sure or vaccum system. We do not recommand putting anti-freeze into the heat pump
pipes,but ifyou chose toput some, make sure itis compatiblewith copper, otherwise, it
woulddo moredamage tothe condenser thansmall quantityof icewould;
5.If theheat pumpis leftoutsideduringwinter,protect itwith awaterproof cover.
Winterizing (Titanium heat exchanger)
Ifyouclosetheswimmingpoolduring thewinterseason, it isessentialtodrainthe unit in
order to prevent the formation of ice in the condenser (water section). To winterize the heat
pump,youmust:
1.Stopthe unit;
2.Shut offthebreaker ofthe heatpump electricalsupply line;
3.Loseen the bypassvalves (photo A)and letthe water drainout (See “WaterDeriva
tion”for details.);
4. Unscrew the small cap (photo B) with the help of two wrenches (photo C) and freely
flush the condenser with tap water. Completely drain the system using air pressure or
vaccumsystem.Store thesmallcap duringwinter.
5.Block the opening of eitherthe water inlet or outletpipe (photo D) with your hand and
blowairintothepipenotcoveredbyyourhandtoflushoutthewatercompletely.Iftheheat
pumpis leftoutsideduringwinter,cover itwith awaterproof cover.