Trotec TGP 1000 E User manual

TRT-BA-TGP1000E-TC2018-64-001-EN
TGP 1000 E
EN
ORIGINAL INSTRUCTIONS
GARDEN PUMP

2 EN
garden pump TGP 1000 E
Table of contents
Notes regarding the instructions ..........................................2
Safety .....................................................................................2
Information about the device................................................6
Transport and storage...........................................................6
Assembly and installation.....................................................7
Operation .............................................................................10
Errors and faults..................................................................11
Maintenance ........................................................................11
Technical annex...................................................................12
Disposal ...............................................................................13
Declaration of conformity ...................................................13
Notes regarding the instructions
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
You can download the current version of the instructions and
the EUdeclaration of conformity via the following link:
TGP 1000 E
https://hub.trotec.com/?id=42890
Safety
Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!
Warning
Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may
result in electric shock, fire and/ or serious injury.
Save all warnings and instructions for future
reference.
This appliance can be used by children aged from
8years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.
General safety
• Do not use the device in potentially explosive rooms.
• Do not use the device in aggressive atmosphere.
• Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.
• Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.
• When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.
• Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

EN 3
garden pump TGP 1000 E
General safety warnings – Electrical safety
• The device is to be supplied with a rated residual current
of no more than 30mA by means of an RCD (Residual
Current protective Device).
• Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!
• The electrical connection must correspond to the
specifications in chapter Technical data.
• Insert the mains plug into a properly secured mains
socket.
• Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.
• Do not under any circumstances use the device if you
detect damages on the mains plug or power cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!
• Should the connection line of the device be damaged, it
must be replaced by the manufacturer, his customer
service or similarly qualified personnel in order to avoid
hazards.
• Should there be a risk of flooding, install the plug
connections in a flood-proof area. There is a risk of
electric shock!
• Make sure that the mains voltage corresponds to the
specifications on the nameplate.
• Have all electrical installations carried out by an expert
according to the national regulations and the device-
specific requirements.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Protect the power supply cable against heat, oil and sharp
edges. Make sure that the power supply cable is not
crushed, kinked or subjected to other mechanical stresses.
• Only use splash-proof extension cables intended for
outdoor use whilst observing the device's power input.
Before using cable drums, always unroll the cable
completely. Check the cable for damage. The use of
extension cables which are not approved for outdoor use
can result in injuries due to electric shock.
• Before performing any work on the device, in case of leaks
in the water system, before taking work breaks or when
not in use, remove the mains plug from the mains socket.
General safety warnings – Personal safety
• Never use the device with persons or animals in the water
or pumping medium or if they could access it. There is a
risk of electric shock!
• Never insert any objects or limbs into the device.
• This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.
Device-specific safety warnings for garden pumps
• Do not position the device in damp shafts. There is a risk
of short circuit as well as damage caused by corrosion!
• Please bear in mind, that the device is not suitable for
continuous operation (e.g. for watercourses in garden
ponds). Check the device for proper functioning on a
regular basis.
• The device is not to be carried by holding it at the power
supply cable or hose. Do not fasten it there either.
• After the set-up of the device, its mains plug must be
readily accessible during operation.
• Wear sturdy shoes to protect yourself against electric
shock.
• Before taking the device into operation, have the following
checked by an expert:
– earthing, neutral conductor and RCD must be
functioning properly and correspond to the national
regulations,
– electrical plug connections must be protected from
moisture.
• Provide appropriate frost protection.
• Never operate the device in the rain. Keep the device away
from environmental influences such as wet conditions or
frost. In particular, keep the electrical connections dry and
make sure they are located in a flood-proof area.
• Never operate the device when dry or with the suction line
closed. The intake opening of the suction line must always
be submerged in the pumping medium.
• Do not use the device at freezing temperatures or
temperatures above 40°C.
• Do not pump any contaminated media or liquids with a
temperature of more than 35°C. Pumping contaminated
media can cause damage to the inside of the device.
• Do not under any circumstances pump brine, aggressive
liquids (alkalis, acids, etc.), combustible or explosive
liquids (petroleum, petrol, etc.) or food (drinking water,
etc.).

4 EN
garden pump TGP 1000 E
• Risk of injury due to hot water. The water inside the device
can heat up during operation and cause injuries.
• Check the device for damage at regular intervals prior to
use. Pay particular attention to the mains cable and plug.
In the event of damage or functional restrictions, the
device must no longer be used until it has been repaired by
an expert. Only original spare parts may be used for this
purpose.
• Do not use the device for drinking water supply, and do not
integrate it into the drinking water circuit. In addition,
please observe the local regulations of the water and
wastewater authorities.
• Do not operate the device for more than 10min when the
pressure line is closed.
Intended use
The device TGP 1000 E is designed for pumping clear water
serving as service water in the home and garden.
The device can be applied for the following pumping media:
• well water
• rain water from rain barrels or cisterns
• water from ponds and streams (with an appropriate
pre-filter)
The device is suitable for the following fields of application:
• watering gardens and vegetable beds
• operating lawn sprinklers
• service water supply in the home and garden
The water temperature must not exceed 35°C.
Improper use
• The device is not suitable for continuous operation (e.g. as
recirculation pump for ponds).
• Using the device in swimming pools and the like is
prohibited.
• The device is not suitable for increasing the pressure of
existing water supply networks.
• The device is not suitable for pumping potable water.
• The device must not be used for aggressive, abrasive,
caustic, corrosive, combustible or explosive pumping
media, e.g.:
– brine
– sandy water
– food
– cleaning agents
– fuels (e.g. petrol, diesel)
– oils
– greases
– petroleum
– nitro-cellulose thinner
– waste water from lavatories and urinal installations
• The device must not be used at freezing temperatures.
• Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
Personnel qualifications
People who use this device must:
• be aware of the dangers that occur when working with
electric devices in damp areas.
• have read and understood the instructions, especially the
Safety chapter.

EN 5
garden pump TGP 1000 E
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
The following safety signs and labels are attached to the device:
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
Warning of electrical voltage
Information marked with this symbol indicates dangers
to the life and health of persons due to electrical
voltage.
Do not pull the mains plug by the power cable
This symbol indicates that you must not pull the mains
plug out of the socket by the power cable.
Staying in water prohibited
This symbol indicates that the device must not be
operated with persons or animals in the water.
88
Indication of the sound power level LWA indB
Information marked with this symbol indicates the
sound power level LWA indB.
Residual risks
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Behaviour in the event of an emergency
1. Switch off the device.
2. In an emergency, disconnect the device from the mains
feed-in: Hold onto the mains plug while pulling the power
cable out of the mains socket.
3. Do not reconnect a defective device to the mains.
Overheating protection
The device is provided with a thermal protection circuit which is
activated by overheating of the device and then switches the
device off.
Allow the device to cool down and switch it off. Investigate the
cause of overheating. Should the problem persist, please
contact the customer service.

6 EN
garden pump TGP 1000 E
Information about the device
Device description
The device TGP 1000 E is used to pump service water for the
home and garden.
The device is able to suck in clear water from wells, rain water
barrels or cisterns from a depth of up to 7m, and to pump it up
to a height of 42m.
The water temperature must not exceed 35°C.
For a permanent installation, the device is fitted with feet with
drill holes allowing it to be bolted to the ground. The device can
be filled with water via the water filler neck. The water can be
drained via the water drain nozzle.
Device depiction
2
3
4
5
1
8
6
7
No. Designation
1 On/off switch with protective cover
2 Connection for pressure line with 1"internal thread
3 Water filler neck with screw plug
4 Connection for suction line with 1"internal thread
5 Water drain nozzle with screw plug
6 Transport handle
7 Mounting screws for transport handle
8 Foot (with drill hole)
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
To make the device easier to transport, it is fitted with a carry
handle.
Before transporting the device, observe the following:
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Only carry the device by the transport handle.
• Do not carry the device by holding it at the power supply
cable or hose.
Storage
When the device is not being used, observe the following
storage conditions:
• dry and protected from frost and heat
• in an upright position where it is protected from dust and
direct sunlight
• with a cover to protect it from invasive dust, if necessary
• Check whether there is residual water left in the device,
and drain any residual water via the water drain nozzle(5)
to prevent rust formation.
• Put the protective caps on the pressure and suction
connection to protect the inside of the device against dust
and dirt.
If you do not use the device for an extended period of time, it
must be cleaned thoroughly after its last application and before
recommissioning. Deposits and residues could lead to start-up
difficulties.
For restart, please proceed according to the Start-up chapter.

EN 7
garden pump TGP 1000 E
Assembly and installation
Scope of delivery
• 1x Garden pump
• 1x Transport handle
• 2x Screw
• 1x Manual
Unpacking the device
1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power
cable is not damaged and that you do not damage it during
unwinding.
Start-up
Positioning
Warning of electrical voltage
Do not position the device in damp shafts. There is risk
of short circuit!
Note
Positioning the device in damp shafts can result in
damage to the device caused by corrosion!
Select a suitable location for positioning the device. It should
meet the following criteria:
• The site of installation is protected from weather exposure
and wet conditions.
• The surface is horizontal and level.
• The site of installation can support the weight of the device
and the pumped media.
For a permanent installation, the feet(8) of the device can be
bolted to the ground.
Mounting the transport handle
Prior to initial start-up, the transport handle must be attached to
the device. To do so, please proceed as follows:
1. Use the supplied screws(7) to mount the transport
handle(6) to the top of the housing.
6
7
Connecting the pipe or hose line
The device may be operated using either a hose line or a pipe.
Ex factory, the device is delivered with a 1" internal thread.
Please note the following:
• The device cannot be moved flexibly when using a solid
pipe.
• Use a pressure line and suction line with a diameter
corresponding to the size of the connections or above.
A smaller diameter causes pressure loss and thus reduces
the feed rate.
• The smaller the pump height of the pressure line and
suction line, the higher the feed rate.
• Connected accessories can cause a pressure loss and
reduce the feed rate.
Additionally, please note the following when connecting flexible
hose lines:
Note
If you want to connect a flexible hose as pressure line,
do not use a suction hose or a non-pressure-resistant
hose. Use pressure-resistant hoses only.
Note
If you want to connect a flexible hose as suction line,
use a vacuum-tight suction hose only.

8 EN
garden pump TGP 1000 E
Connecting the pressure line
Warning
Make sure that all parts of the pressure line are
installed professionally. In case of an improper
assembly or when using unsuitable parts, there is a
risk of injury due to the pressurized pumping medium.
1. Remove the protective cap(9) from the pressure
connection(2).
9
2
Note
Keep the protective cap of the pressure connection so
you can use it when storing the device to protect the
inside of the device against dust and dirt.
2. Connect the pressure line to the pressure connection(2).
To do so, apply thread seal tape (e.g. Teflon tape) to the
threaded connector of the pressure line to ensure a leak-
proof connection.
Connecting the suction line
1. Remove the protective cap(10) from the suction
connection(4).
10
4
Note
Keep the protective cap of the suction connection so
you can use it when storing the device to protect the
inside of the device against dust and dirt.
2. Connect the suction line to the suction connection(4).

EN 9
garden pump TGP 1000 E
3. Submerge the intake opening of the suction line at the
point of withdrawal, and make sure the intake opening is
always sufficiently covered with water.
Note
Make sure that the suction line is always installed with
an upward incline. Otherwise, an air bubble may form
at higher parts of the suction line and make the device
run dry.
Note
At the bottom of ponds and other waterbodies deposits
may have accumulated over time. To prevent the
device from being damaged, do not lower the suction
line all the way to the ground. Alternatively, you may
also connect a suitable pre-filter with backflow
preventer to the suction line. This also helps to reduce
the time to restart suction.
Filling the device with water
Warning of electrical voltage
There is a risk of electric shock when filling the device
with water.
Before filling the device, always make sure that the
mains plug has been removed.
1. Open the screw plug at the water filler neck(3).
3
2. Fill the device with the pumping medium all the way to the
edge via the water filler neck(3). The connected suction
line should also be completely filled with the pumping
medium.
3. Screw the screw plug back onto the water filler neck(3).
Ensure a tight fit of the screw plug.

10 EN
garden pump TGP 1000 E
Bleeding the pressure line
Please observe the following information before bleeding or
switching the device on:
• Make sure that the mains connection corresponds to the
specifications provided in the technical data.
• Check the mains socket for its proper condition and
sufficient fusing.
• Make it impossible for moisture to reach mains plug or
socket. There is a risk of electric shock!
• Check whether the pressure and suction line were properly
attached.
1. Open all consumers connected to the pressure line to
bleed the pressure line.
2. Switch on the device as described in the Operation chapter
and wait until the device has sucked in water or until water
flows out of the consumers.
Operation
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Switching the device on
1. Plug the mains plug into a sufficiently fused mains socket.
2. Switch the device on by setting the on/off switch(1) to
positionI.
1
3. After switch-on, regularly check whether the device
operates correctly. Turn off the power supply if after start-
up of the motor the pump shows an unusual operational
behaviour (such as strong vibrations at the pump or
pressure line, a fluctuating feed rate or similar). If you
leave the device unattended for a longer period of time,
interrupt the device's power supply.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Warning
The device is pressurized. Before opening the screw
plug at the water drain nozzle(5) or before
disassembling the pressure line, the pressure must be
released from the pressure line via the lowest-level
consumer.
1. Switch the device off by setting the on/off switch(1) to
position0.
2. Hold onto the mains plug while pulling the power cable out
of the mains socket.
3. Open the lowest-level consumer to reduce the pressure in
the pressure line.
4. Open the screw plug at the water drain nozzle(5) to drain
any residual water from the pressure line and from the
inside of the device.
5
5. Detach the pressure and suction line.
6. Clean the device according to the Maintenance chapter.
7. Store the device according to the Storage chapter.
Table of contents
Other Trotec Water Pump manuals

Trotec
Trotec TGP 1050 E User manual

Trotec
Trotec DS Series User manual

Trotec
Trotec TGP 1000 ES User manual

Trotec
Trotec TWP 4005 E User manual

Trotec
Trotec TGP 1025 E User manual

Trotec
Trotec TWP 4036 E User manual

Trotec
Trotec TDP 370 E User manual

Trotec
Trotec TWP 4006 E User manual

Trotec
Trotec TWP 4005 E User manual

Trotec
Trotec TGP 1025 ES User manual
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual