Tripp Lite S3MT-Series User manual

1
Owner’s Manual
S3MT-Series 3-Phase
Input Transformers:
480V-208V and 600V-208V
Models:
S3MT-60K480V, S3MT-100K480V, S3MT-60K600V, S3MT-100K600V
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2021 Tripp Lite. All rights reserved.
WARRANTY REGISTRATION
Register your product today and be
automatically entered to win an ISOBAR®
surge protector in our monthly drawing!
tripplite.com/warranty
Español 21 • Français 41

2
1. Introduction ................................................................................. 3
2. Important Safety Warnings.......................................................... 5
3. Installation .................................................................................. 6
3.1 Mechanical Data ...................................................................................6
3.2 Package Inspection ..............................................................................7
3.3 Unpacking the UPS ...............................................................................7
3.4 Package Contents .................................................................................9
3.5 Cabinet Overview ................................................................................10
3.6 Power Cables ......................................................................................12
3.7 Transformer-to-UPS Connection Line Diagram ...................................13
3.8 Multiple Transformer Connections......................................................15
3.8.1 S3MT-60K480V/S3MT-60K600V to S3M50K or S3M60K UPS........................ 15
3.8.2 S3MT-100K480V/S3MT-100K600V to S3M80K or S3M100K UPS.................. 15
4. Operations................................................................................. 16
4.1 Over-Temperature Protection..............................................................16
4.1.1 Over-Temperature Red Warning LED Light ................................................... 16
4.1.2 Over-Temperature Protection Relay and Thermal Switch............................. 16
5. Specifications............................................................................ 17
6. Storage...................................................................................... 19
7. Warranty and Regulatory Compliance........................................ 19
Table of Contents

3
1. Introduction
Tripp Lite’s S3MT-60K480V and S3MT-100K480V input isolation transformers provide 480V (Delta) to 208V (Wye) step-
down and Isolation protection to the connected UPS and its load. The S3MT-60K600V and S3MT-100K600V Input isolation
transformers provide 600V (Delta) to 208V (Wye) step-down and isolation protection to the connected UPS and its load.
The transformer has input isolation to mitigate utility line surges and spikes, while protecting the UPS. The transformer
includes a built in breaker at the transformer output side for protection. The ball-bearing fans maintain quiet operation (four
fans for 60K models, three large fans for 100K models). An overheat-sensing relay and switch combine with a warning light
to provide over-temperature warning and overheating protection. The UPS system’s small footprint and quiet acoustic profile
enable installations with minimal space and noise impact. All transformer models feature rugged stainless steel housings with
front panels similar to the S3M-Series 208V 3-Phase UPS line.
UPS Model Series Number Capacity Description
S3MT-60K480V AG-050D 60kW 480V to 208V Input Isolation Transformer
S3MT-100K480V AG-0510 100kW 480V to 208V Input Isolation Transformer
S3MT-60K600V AG-050F 60kW 600V to 208V Input Isolation Transformer
S3MT-100K600V AG-050E 100kW 600V to 208V Input Isolation Transformer
Typical applications
4-Wire (3Ph+N+PE) IT equipment loads in government, manufacturing, hospitals, industrial settings and corporate settings
that have 480V or 600V electrical mains and 208V/120V or 220V/127V IT Loads.
Key Features
• Isolation protection to the UPS input, with stepped-down input from 480V (Delta) to 208V/120V (Wye) or 600V (Delta) to
208V/120V (Wye)
• Circuit breaker and overheating protection
• 96.5% to 97.5% efficiency
• Wide input voltage and frequency operating range:
Voltage: -20% to +25% @ 100% load and 40-70 Hz
• Insulation class: 180°C material
• Reliability-tested according to ISTA-3B for vibration, shock, drop (tip test)
• UL and CSA TUV certifications
• Rugged stainless steel housing shipped ready for installation
• 2-year warranty

4
1. Introduction
Typical Configurations
These 480V Input Transformers may be purchased separately or as part of kit model with a Tripp Lite S3M Series 3-Phase UPS:
Input
Transformer Models
Maximum
Constant Load
Compatible with
208V 3Ph UPS
Kit Models: UPS + Transformer
Kit Models Kit Models Include
480V
S3MT-60K480V 60kW 50-60kW UPS
S3M50K-60K4T S3M50K UPS +
S3MT-60K480V
S3M60K-60K4T S3M60K UPS +
S3MT-60K480V
S3MT-100K480V 100kW 80-100kW UPS
S3M80K-100K4T S3M80K UPS +
S3MT-100K480V
S3M100K-100K4T S3M100K UPS +
S3MT-100K480V
600V
S3MT-60K600V 60kW 50-60kW UPS
S3M50K-60K6T S3M50K UPS +
S3MT-60K600V
S3M60K-60K6T S3M60K UPS +
S3MT-60K600V
S3MT-100K600V 100kW 80-100kW UPS
S3M80K-100K6T S3M80K UPS +
S3MT-100K600V
S3M100K-100K6T S3M100K UPS +
S3MT-100K600V
480V, 600V,
208V/120V,
(Wye)
UPS UPS
WYE-
Load
208/120V
220/127V
WYE-
Load
208/120V
220/127V
208V/120V,
(Wye)

5
CAUTION! Risk of electrical shock! Hazardous live parts inside this unit are energized from the transformer even when
the breaker is turned off.
WARNING! The unit intended for installation in a controlled environment.
CAUTION! A transformer can present a risk of electric shock and high short circuit current. The following precaution should
be observed when working on the transformer:
• Remove watches, rings or other metal objects.
• Use tools with insulated handles.
To reduce the risk of electric shock, disconnect the transformer and UPS from the mains supply before performing
maintenance or service.
Servicing of the 3-phase transformer and UPS should be performed by Tripp Lite certified personnel with knowledge of the
3-phase transformer and UPS and all required precautions.
The transformer is extremely heavy. Caution should be taken in moving and positioning equipment. The instructions contained
within this manual are important and should be closely followed at all times during installation and follow-up maintenance of
the 3-phase transformer and UPS.
CAUTION!
The transformer has a dangerous level of heat. If the transformer’s front-panel red LED indicator is on,
the unit’s outlets may have a dangerous level of heat.
All servicing on this equipment must be carried out by Tripp Lite-certified service personnel.
Before conducting any maintenance, repair or shipment, first ensure everything is turned off completely
and disconnected.
Special Symbols – The following symbols are used on the transformer to warn you of precautions:
RISK OF ELECTRIC SHOCK - Observe the warning that a risk of electric shock is present.
CAUTION - REFER TO THE OWNER’S MANUAL for information regarding important operating and
maintenance instructions.
SAFE GROUNDING TERMINAL - Indicates THE primary safe ground.
2. Important Safety Warnings
SAVE THESE INSTRUCTIONS
This manual contains important instructions for models S3MT-60K480V / S3MT-100K480V / S3MT-60K600V /
S3MT-100K600V that should be followed during installation and maintenance of the transformer and UPS.

6
3. Installation
3.1 Mechanical Data
Physical Requirements
Leave space around the cabinet for operation and ventilation (Figure 3-1):
1. Leave at least 23.6 in. (600 mm) space in the front for ventilation
2. Leave at least 20 in. (500 mm) space at the right and left for operation
3. Leave at least 20 in. (500 mm) space at the back for ventilation
Figure 3-1
23.6”
(600 mm)
47.2”
(1200 mm)
33.5”
(850 mm)
≥20”
(500 mm)
≥20”
(500 mm)
≥20”
(500 mm)
≥20”
(500 mm)
≥23.6”
(600 mm)

7
3. Installation
3.2 Package Inspection
1. Don’t lean the transformer cabinet when removing it from the packaging.
2. Check the appearance to see if the transformer cabinet was damaged during transport. Do not power on the transformer
cabinet if any damage is found. Contact the dealer immediately.
3. Check the accessories against the packing list and contact the dealer in case of missing parts.
3.3 Unpacking the UPS
1. Hold the sliding plate steady. Cut and remove the binding
straps (Figure 3-2).
Figure 3-2
2. Remove the plastic bag and the outer carton (Figure 3-3).
Figure 3-3

8
3. Installation
3. Remove the foam packing material and the beveled pallet
(Figure 3-4).
Figure 3-4
4. Remove the screws securing the cabinet to the pallet
(Figure 3-5).
Figure 3-5
5. Lift the cabinet with a forklift and remove the packing pallets (Figure 3-6).
Figure 3-6

9
3. Installation
3.4 Package Contents
Contents TL P/N S3MT-60K480V S3MT-60K600V S3MT-100K480V S3MT-100K600V
Input Transformer 1 1 1 1
Owner’s Manual 933D05 1 1 1 1
Bottom Skirts 103922A 2 2 2 2
Bottom Skirts 103923A 2 2 2 2
Screws for Skirts 3011C3 24 24 24 24

10
3. Installation
3.5 Cabinet Overview
1Over-Temperature Alarm LED
2Cooling Fans
3Breaker with Trip
4Cabling Terminals
5Bottom Entry Knockouts
(for Power Cable Entry and Exit)
Rear View,
S3MT-60K480V / S3MT-60K600V
Rear View,
S3MT-100K480V / S3MT-100V600V
Front View
12 2
5
4
3
Front View (Terminal Block without Cover), S3MT-60K480V / S3MT-60K600V
This manual suits for next models
4
Table of contents
Languages:
Other Tripp Lite Transformer manuals

Tripp Lite
Tripp Lite Medical Grade IS Series User manual

Tripp Lite
Tripp Lite IS Medical IS500HG User manual

Tripp Lite
Tripp Lite SU5000XFMR2UTAA User manual

Tripp Lite
Tripp Lite Isolator Series User manual

Tripp Lite
Tripp Lite IS Medical Grade IS250HG User manual

Tripp Lite
Tripp Lite Full Isolation UPS Systems none User manual

Tripp Lite
Tripp Lite S3MT Series User manual

Tripp Lite
Tripp Lite S3MT Series User manual

Tripp Lite
Tripp Lite Isolator Series UL60601-1 User manual

Tripp Lite
Tripp Lite IS1000 User manual