Date: 2019.05.06 Doc No: PS-M-0692 Ver. A Page - 5 - of 13
Where common grounding hardware (nuts, bolts, star washers, spilt-ring lock washers, flat washers and
the like) is used to attach a listed grounding/bonding device, the attachment must be made in conformance
with the grounding device manufacturer's instructions.
Common hardware items such as nuts, bolts, star washers, lock washers and the like have not been
evaluated for electrical conductivity or for use as grounding devices and should be used only for
maintaining mechanical connections and holding electrical grounding devices in the proper position for
electrical conductivity.
Rated electrical characteristics are within ± 10 percent of measured values at Standard Test Conditions of
1000 W/m², 25°C cell temperature and AM 1.5 solar spectral irradiance.
The fire rating of a Trina Solar PV module is valid only when mounted in the manner specified in the
mechanical mounting instructions of this installation manual.
Modules equipped with PV wiring connectors that comply with the Standard for Connectors for Use in
Photovoltaic Systems, UL 6703, shall have the specific allowable mating connector manufacturer(s) and
model number(s) listed, as well as contact information and/or website of the PV connector manufacturer. If
a specific module product is available with multiple PV wiring connectors from various manufacturers, then
the following shall be included: 1) Means to identify each distinct PV connector manufacturer's product -
such as a picture or illustration, unique physical features, markings, company logos, etc, and 2) Allowable
mating connector manufacturer and model number(s) listed for each distinct cable connector
manufacturer's product(s), as well as contact information and/or website of the PV connector
manufacturer.
3. UNPACKING AND STORAGE
At time of receipt, verify that the product delivered is in fact the product ordered. The product name,
subname, and serial number of each laminate are clearly marked on the outside of each packing box.
Leave the product in its original packing box until you are ready to install.
Store packing boxes in a clean, dry area with relative humidity below 85% and storage temperatures
between -20°C and 50°C.
Do NOT stack more than the maximum amount of allowable pallets on top of each other.
At the installation site, take care to keep modules and particular their electrical contacts clean and dry
before installation. If connector cables are left in damp conditions then the contacts may corrode. Any
module with corroded contacts should not be used.
If pallets are stored temporarily outside then place a protective covering over the pallet to protect it from
direct weathering and do not stack more than 1 pallet high.
Two people are required to unpack the modules from the packing box, when handling modules always use
both hands.
Protect the module edges for temporary storage outside the pallet.
Do NOT use a knife to cut the zip-ties, but use wire cutting pliers.
Do NOT place modules directly on top of each other.
4. PRODUCT IDENTIFICATION
Each individual module has a unique serial number laminated behind the glass and another permanently
attached to the back-sheet of the module on the product sticker. Note all serial numbers in an installation for
your future records.
5. ENVIRONMENTAL CONSIDERATIONS AND SITE SELECTION
5.1 CLIMATE CONDITIONS
Trina Solar Crystalline series modules may be installed in the following conditions for more than 25 years. In
addition to the required IEC certification, Trina Solar products have also been tested to verify resistance to
ammonia fumes that may be present around barns sheltering cattle, as well as suitability for installation in
humid (coastal) areas and areas of high sand storms.
Environment
Operating temperature: -40°C to +85°C
Storage temperature: -20°C to +50°C