TOTALINE IntelliMist User manual

OWNER'S MANUAL
INTELLIMIST
HUMIDIFIER
P/N P110-300
Replacement Components Division Carrier Corporation 3/01
INTELLIMIST MicroFine Spray
MICROPULSE Technology
Assures Maximum Efficiency
Scale Reducing Filter Included
Up to 24 Gallons Per Day of
Additional Humidity
For Use With 1 - 7 Ton HVAC
Systems
Designed For Use Only With:
P110-0009 Humidistat
P474-3000 Humidistat
P374-1600 INTELLISTAT
TOTALINE
USE ONLY WITH CENTRAL AIR CONDITIONING SYSTEMS.
THE HUMIDIFIER MUST BE MOUNTED OVER THE
EVAPORATOR COIL OR EVAPORATOR COIL DRAIN PAN.
IF THERE IS NOT A DRAIN PAN, ONE MUST BE INSTALLED.
PATENTS PENDING
TM
TOTALINE
Humidifier
IntelliMist
4Z95
MODEL P11 0-300
R
C
H1
H2
TM
24vac 7.5w
Intellimist
On
For
Residential
Use Only

INTELLIMIST HUMIDIFIER
TABLE OF CONTENTS
CONTENTS & ACCESSORIES.....................2
MOUNTING LOCATIONS..............................3
ASSEMBLY & INSTALLATION.......................4
WATER HARDNESS......................................6
WATER FILTER..............................................7
WIRING DIAGRAMS......................................8
TROUBLE SHOOTING GUIDE.....................11
OUTPUT CHECK..........................................16
Page 1

Page 2
CAUTION
Follow Installation Instructions for Humidifier carefully.
UNIT MUST NOT BE INSTALLED WHERE FREEZING TEMPERATURES
MAY OCCUR. DO NOT INSTALL ON FURNACE JACKET, OR WHERE
UNIT AND ITS COMPONENTS MAY COME INTO CONTACT WITH HOT SURFACES.
PACKAGE CONTENTS
P110-300 INTELLIMIST Humidifier Assy.
#0862 Tube Assy.
#0759 INTELLIMIST In-Line Water Filter
#0800 Water Filter Mounting Bracket
#0152 Mounting Kit
AVAILABLE INTELLIMIST ACCESSORIES
P110-0009 Humidistat
P474-3000 Humidistat
P374-1600 INTELLISTAT
(Combination Thermostat / Humidistat)
P110-0008 Replacement Filter / Nozzle
INTELLIMIST HUMIDIFIER
This Humidifier MUST be used with Totaline
P110-0009, P474-3000 Humidistats or P374-1600 INTELLISTAT.
USE ONLY WITH CENTRAL AIR CONDITIONING SYSTEMS.
THE HUMIDIFIER MUST BE MOUNTED OVER THE
EVAPORATOR COIL OR EVAPORATOR COIL DRAIN PAN.
IF THERE IS NOT A DRAIN PAN, ONE MUST BE INSTALLED.

Page 3
11SELECT MOUNTING LOCATION
1. The humidifier should be installed on the supply plenum,
preferably near the coil. Mounting near the evaporative
coil, if applicable, will allow any excess moisture to exit
the system via the condensation drain pan.
2. On vertical equipment allow clearance of the humidifier
and related components such as the water filter and
plastic water live, from the exhaust vent.
3. On vertical equipment, if the nozzle is spraying away
from the coil, there should be a minimum of three feet
from the nozzle to the top of the plenum. If this is not
available, then point the nozzle of the humidifier
directly into the evaporative coil.
4. Always install downstream of an electronic air cleaner.
Drill or ‘knock out’ a 1” hole & 4 mounting holes for the
#6 screws on the mounting template.
INTELLIMIST HUMIDIFIER
AIR FLOW
HUMIDIFIER
DRAIN
PAN
EVAPORATOR
COIL
PLENUM
FURNACE
HORIZONTAL
EQUIPMENT
HUMIDIFIER
ALTERNATE
LOCATION
ALTERNATE
LOCATION
FURNACE
EVAPORATOR
N-COIL
PLENUM PLENUM
EVAPORATOR
A-COIL
FURNACE
DRAIN PANS
HUMIDIFIER
VERTICAL VERTICAL

Page 4
INTELLIMIST HUMIDIFIER
MOUNTING NUT
TUBE ASSY
22ASSEMBLE THE HUMIDIFIER
Slide the mounting nut over the tube
(fig. 1)
assembly.
Insert the tube assembly into the humidifier
valve. Secure by turning the nut clockwise
until finger tight, then additional 1/4 turn.
(fig. 2)
Fig. 1
Fig. 2
33INSTALL THE HUMIDIFIER
Be sure to use a cold water
connection.
Mount the humidifier to the sheet
metal using the four #6 mounting
screws supplied. (Page 3)
The in-line water filter should be
mounted below or to one side of
the humidifier assembly in a vertical
position as shown. (Fig. 3)
Be sure the flow arrow on the filter is
pointing to the humidifier.
Fig. 3
RR
CC
H1H1
H2H2
INTELLIMIST
ON
INTELLIMIST
HUMIDIFIER
MODEL: P110-300
24 VAC 7.5 WATTS
UULL
CUS
LISTED
4Z95
TOTALINE

Page 5
44WATER CONNECTION
Run 1/4” tubing from the water supply to the
in-line filter. The saddle valve and tubing
is supplied for this purpose.
SADDLE VALVE INSTALL
The self piercing
is for copper pipe
of pipe, drill a 1/8” hole in the pipe. Turn the
handle clockwise to expose the piercing pin
beyond the seal approximately 3/16”. Place
the body of the valve over the hole in the
pipe so the pin fits in the hole. Tighten the
bottom clamp evenly. Turn handle clockwise
and close the valve.
feature of the saddle valve
only. All other materials
INTELLIMIST HUMIDIFIER
CAUTION
SAFETY NOTE
USE COPPER TUBING WHERE INSTALLATIONS
MAY CAUSE DAMAGE IF A WATER LEAK OCCURS.

Page 6
INTELLIMIST HUMIDIFIER
WATER HARDNESS
If water hardness is 15 grains/gal or under the filter & nozzle
(P/N P110-0008) should be replaced once a year.
If the water hardness is higher than 15, the filter & nozzle
should be replaced every 3 months during the heating season.
If the humidifier is run with the fan in the non-heating season,
then the filter/nozzle should be replaced every 6 months.
Water hardness test kits are available at local home
improvement centers.
Rotary PinOrifice
Nozzle
Water
Filter

INTELLIMIST HUMIDIFIER
WATER FILTER
Page 7
The water filter should be mounted using the supplied
bracket. (Figure 4)
Up to 3 gallons of water should be run through the filter
from the supply
before connection to the humidifier. This may be
done using a short piece of tubing on the output of the filter.
Connect to the humidifier and check for leaks.
until the water appears clear, not gray or
cloudy,
Fig. 4
SUPPLIED
BRACKET
The water filter supplied with the humdifier is specifically
formulated for optimal operation. The filter design inhibits
bacteria, odor, and calcium buildup. The filter should only be
replaced with Totaline part # P110-0008.
In the rare instance white powder is noticed on the interior of
the house, this is an indication the filter needs to be replaced.
Polyphosphate
Clear, Plastic Case
KDF Activated Charcoal
4) 5 Micron Filter Screens

55
Page 8
WIRING DIAGRAMS
When R & C are used from a nearby thermostat:
If only 1 wire is available from the furnace to the humidistat, W1
may be obtained from the thermostat.
R
R
R24vac
24vac
C
W1
W1
C
R
C
C
C
C
Humidistat
P110-0009
P110-0009
Humidistat
Thermostat
Furnace
Furnace
Humidifier
Humidifier
HUM
HUM
H1
H1
H1
H1
H2
H2
INTELLIMIST HUMIDIFIER

55
Page 9
WIRING DIAGRAMS
When connected to the IntelliStat (P374-1600):
R
W1
R
R
C
C
C
Humidistat
Furnace
Humidifier
HUM
H1
H1
H2
The C & R terminals on the
IntelliMist Humidifier are
not connected internally.
They are provided for an
easy ‘tie-off point’ when
using 1 multi-conductor
cable from the Humidifier
to the humidistat. In this
case H2 would need a
jumper to C.
Y2
HUM
Y1
W2
W1/O/B
G C R
Furnace
Humidifier
R
W1/O/B
Y1
Y2
W2
C
G
Intellistat
W3
H1 H2 CR
P110-0009
P374-1600
INTELLIMIST HUMIDIFIER
24vac
24vac