BDG250
MAINTENANCE
Daily cleaning: The motor in use should always be kept clean. No water, or debris
should be allowed to get into the interior of the motor.
Check on load current: While the motor is in operation, constant care should be taken
to keep the load current below the maximum recommended motor current rating.
Operational sounds: During operation of the motor there must be no rubbing sounds,
shrieks or other random noises. Stop the motor immediately and restart after
inspection and corrections have been made.
Check folding handle latch periodically. This is adjustable. To adjust, loosen the lock
nut on the latch and then screw in until a satisfactory tension has been
achieved.
The wheel bearings use sealed bearings and require no regular greasing.
*NB To minimize vibration and uneven blade wear, rotate plate every 2 hours.
Failure to do so can lead to premature wear of the exible coupling.*
**Ensure all re-tipped and new grinding plates are properly balanced.**
FAULT DIAGNOSIS
Symptom Possible Cause Action
Machine will not start
No power is available. Check that the power cable
is plugged in / switched on.
Machine is trying to start on
glue or sticky substance.
Clear a patch with scraper
and grind into the glue a
little, preventing build up.
Extension cord is too thin
or is too long.
Upgrade the extension
cord to a larger cable.
Grinder runs for 5-15
minutes, then stops.
The current allow screw is
not adjusted properly.
Adjust the current screw to
the right position.
Extension cable too long
and/or not made from
heavy enough cable.
Get electrician to check
extension lead
compatibility.
Grinder runs but does not
perform adequately. Motor defective. Repair or replace.
Grinder vibrates during use. Grinding plates not
correctly balanced.
Replace or re-balance
grinding plates.
Grinding noise coming from
grinding head when up on
jockey wheel.
Excessively worn motor
bearings. Have motor serviced.