Tomar TRX-EL TORO User manual

IS1083
TOMAR OFF-ROAD, 2100 W OBISPO AVE, GILBERT, AZ 85233
800-338-2133 www.tomaroff-road.com
TRX-EL TORO
TRX-30CA-AC-FS
TRX-40CA-AC-FS
TRX-50CA-AC-FS
TRX-30CA-FS
TRX-40CA-FS
TRX-50CA-FS
Product Manual

IS1083
Page 2 of 8
!"#$%&'()&'*"#+,--./01-234-'%5-"667%/89-:;<=>?81-=8@-?332-32<;233139->/-
A1/B;93- C/0- A/43160:D- 13:;8?:3- @31B;E3- 6/1- F82C- C381@- >/- E/F3G- - *2- >=;@-
;2@>10E>;/2- @=33>D- C/0- 4;::- 2/>- /2:C- 6;29- >3E=2;E8:- ;26/1F8>;/2D- ?0>- E813-
;2@>10E>;/2@- 8@- 43::D- 6/1- F8;2>8;2;2<- >=3- /1;<;28:- A316/1F82E3- /6- C/01- 234-
'"H&%-%0<<39-IJ>13F3-K'%5L-"667%/89-);<=>?81G---
'=82M-C/0-6/1-C/01-A01E=8@3,-
N;1;2<-
Main%Power%Wires%
Wiring the TRX lightbar into the vehicles electrical system does not require the use of relays. The power
and ground leads are connected directly to the 12Vdc to 24Vdc supply voltage and are always hot.
• Red to +Vdc
• Black to -Vdc
Control%Cable%
Activating the Lightbar is done by applying +Vdc to one or more of the lightbar control wires. The control
wires consume only a few milliamps of current and can be used with virtually any on/off switch. There are
five control wires in the Control Cable plus one +Vdc supply feed.
The control wires are color coded and control the functions shown below. Keep in mind that not all
lightbars will be configured in such a way that all control wires are used.
• Orange - Group 1 lamps
• Blue - Second Color lamps
• Brown/White - S.O.S. or warning pattern
• Brown wire - Running lamp
• Green wire - Dimming of all lamps
• Red/White - +Vdc
Orange'Wire'– On single color single beam pattern bars the orange wire will turn on the entire bar. If the
lamps in the lightbar are two beam patterns, half spot and half flood for example, the orange wire will
turn on just the spot lamps.
Blue'Wire'– If all the lamps in the lightbar have the same beam pattern, the blue wire will have no effect
on the lightbar and can be ignored. If the lamps in the lightbar are two different beam patterns, some
spot and some flood for example, the blue wire will turn on just the flood lamps. If you have a multi-beam
pattern lightbar and just want on/off functionality simply wire both the orange and blue wires to a single
switch.
If the lightbar is configured as a COLOR/white combination bar, the orange wire will activate the white
lights and the blue wire will activate the COLOR lights. In case both the orange and blue wires are activated
at the same time the COLOR lights will activate and the white lights will shut off. The COLOR lights can be
amber, red, blue or green.
Brown'Wire'- If the lightbar is configured as a COLOR/white combination bar, and the COLOR lights are
activated, the Brown wire will force one lamp to remain white to serve as the required front facing white
light.

IS1083
Page 3 of 8
Brown/White'Wire'–Activates the S.O.S. or warning patterns. See below for available flash patterns.
Green'Wire'– In all lightbars the green wire activates a low intensity or dim setting.
Red/White'Wire'– In all lightbars the red/white wire is a +Vdc feed that can be used to power one or
more switches.
COLOR/White%Combo%Available%Flash%Patterns%and%Rates:%
Patterns'
1) Off
2) COLOR Combination (Patterns 5,4,6 Repeat) Default Pattern
3) White S.O.S.
4) COLOR Alternating
5) COLOR Random
6) COLOR Sweep
Rates'
1) Single – Default Rate
2) Double
3) Neobe
4) Scroll
Note: The White S.O.S. Flash Pattern has a fixed Flash Rate (5 WPM, not listed above).
Changing%Patterns%and%Rates:%
To'Enter'Programming'Mode:'
1) All Inputs Open, apply Power and Ground to the lightbar (red and black wires).
2) Connect Green wire to +Vdc.
3) Wait at least one second, Double Tap the Brown wire to +Vdc. All the lamps should flash 3 times to
indicate you've entered Programming Mode.
Note: The Double Tap of the Brown wire must occur within 4 seconds of connecting the Green wire to
+Vdc, otherwise the lightbar will NOT enter Program Mode and will operate normally.
To'change'the'Flash'Pattern:'
1) Brown/White wire must be Open, i.e. not connected to +Vdc.
2) Tap the Brown wire to +Vdc to step forward through the patterns.
3) Tap the Brown wire to +Vdc twice to step backward through the patterns.
4) Touch and Hold the Brown wire to +Vdc for 3 seconds to reset the pattern to the default flash pattern.
To'change'the'Flash'Rate:'
1) Connect the Brown/White wire to +Vdc.
2) Tap the Brown wire to +Vdc to step forward through the flash rates.
3) Tap the Brown wire to +Vdc twice to step backward through the flash rates.

IS1083
Page 4 of 8
4) Touch and Hold the Brown wire to +Vdc for 3 seconds to reset the pattern to the default flash rate.
Wire%Runs%
The table below lists the maximum recommended wire run for the power and ground cables in feet. The
control cable can be the same length as the power cables but 20-gauge wire is sufficient for all distances.
Common%Switch%Wiring%Configuration%
' '
'
%
%
%

IS1083
Page 5 of 8
H/02>;2<-
-
The TRX-El Toro will come with the mounting bolts already installed on the bottom of the lightbars.
1) Remove the bumper
2) Measure and space the bolts along bumper, then add washer and nut and tighten
3) Add jam nut and washer for height adjustment
4) Loosen hex screws on hinges to allow bar to conform to bumper contour

IS1083
Page 6 of 8
5) Mount on bumper, aligning mounting bolts to bumper slots
6) Turn jam nut to adjust height
7) Add washer and lock nut to bolt and tighten to fasten lightbar into place
8) Tighten hex screws on hinges to set the angle

IS1083
Page 7 of 8
9) Verify lightbar height, if adjustments are needed repeat step 5
Recommended%Fuse/Breaker%Sizing%
%
Replacing%a%lamp%module%
All TRX lamp modules are interchangeable and can be used in any position on the lightbar. This offers the
flexibility to configure a lightbar for any mission with perfect balance of flood, spot or dual color modules.

IS1083
Page 8 of 8
With this modular design the replacement of a TRX Lamp couldn’t be easier. Each module is hermetically
sealed so replacement will not compromise the watertight integrity of the lightbar or void the warranty.
To replace a lamp module simply remove the two lamp clips using a 9/64” hex tool. Unplug the lamp from
the waterproof connector, plug the new lamp in and reattach the lamp clips.
H8;2>3282E3--
The best cleaning method is to gently wash the lightbar with a solution of mild soap and lukewarm
water, using a soft cloth or sponge to loosen any dirt or grime. Thoroughly rinse with clean water
to remove any cleaner residue and dry the surface with a soft cloth to prevent water spotting.
If using a high-pressure water cleaner and/or a steam cleaner the pressure should not exceed
1,450psi. The use of additives to the water and/or steam should also be avoided.
Important%Considerations%for%Lexan%lenses:%
• Never use abrasive or highly alkaline cleaners.
• Never use aromatic or halogenated solvents like toluene, benzene, gasoline, acetone or carbon
tetrachloride.
• Contact with harsh solvents such as methyl ethyl ketone (MEK) or hydrochloric acid can result in
surface degradation and possible crazing.
• Never scrub lenses with brushes, steel wool or other abrasive materials.
This manual suits for next models
6
Table of contents
Other Tomar Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Qazqa
Qazqa Suplux SL 3 Black 103062 instruction manual

Commercial Electric
Commercial Electric 54568141 Use and care guide

CREE LIGHTING
CREE LIGHTING 304 Series installation instructions

Goobay
Goobay 49867 user manual

ECOMAN ITALIA
ECOMAN ITALIA LED T8 instruction manual

Alkalite
Alkalite Krypton KT-81 user manual