Tetra WP 300 User manual

2WP300 / WP600 / WP1000
1 2 3 456
WP0001
A
WP0003
B
WP0002
C

3
WP0004
min.–max.
E
WP0005
F
WP0006
1.
2.
D

4WP300 / WP600 / WP1000
UK
WARNING
• This device is suitable for use
by children aged 8 and over as
well as people with reduced
physical, sensory or mental
capacities or a lack of expe-
rience and knowledge if they
are supervised or have been
instructed how to safely use
the device and understand the
resultant risks.
• Children must not play with the
device.
• Children must not conduct
cleaning or user maintenance
activities without supervision.
• Switch o and unplug all de-
vices in your aquarium before
reaching into the water.
• Do not use the device if the
electrical cables or housing are
damaged.

5
UK
SAFETY INSTRUCTIONS
Preventing hazardous situations
• Only connect the WP 300 / WP 600 / WP 1000 to
a professionally installed plug socket.
• Only connect the WP 300 / WP 600 / WP 1000 to
the mains if the local supply voltage corre-
sponds to the specifications in the technical
data.
• Protect the power plug from moisture.
• Always disconnect the water pump from the
mains before cleaning or carrying out any
maintenance tasks.
• Do not allow children to play with small parts as
there is a risk of choking.
• The power plug must be freely accessible so
that the water pump can be easily and quickly
disconnected from the mains in an emergency.
• Never make any technical changes to the
device.
• Damaged connection cables cannot be re-
placed. Dispose of the device.
Preventing material damage
• Do not bend or crush the mains connection
cable.
• Only use original spare parts and accessories.
Note the symbols on the device
Do not dispose of the device with house-
hold waste; send for recycling.
Protection class II: Metal parts which can
lead to voltage failure are insulated.
Intended for indoor use only.
ABOUT THIS MANUAL
The manual goes with the WP 300 / WP 600 /
WP 1000 and must be stored for future reference.

6WP300 / WP600 / WP1000
UK
SCOPE OF DELIVERY
Fig. A
1 Pump body
2 Friction bearing, spare part (only for WP 600 / WP 1000)
3 Impeller
4 Pump housing
5 Suction cups (WP 300: 2x, WP 600 and WP 1000: 4x)
6 Flow regulator
INTENDED USE
Only use WP 300 / WP 600 / WP 1000
• for water circulation in aquariums,
• in indoor areas,
• for private use,
• in line with the technical data,
• at water temperatures of +4 °C ... +35 °C.
SET-UP
1. Fig. B: Fix the suction cups to the underside of
the pump body and pump housing.
2. Fig. C: Fix the water pump to the aquarium wall
or bottom beneath the surface of the water with
the suction cups.
INITIAL USE
1. Fig. D: Use the flow regulator to adjust to the
desired water flow.
2. Fig. E: Form a "drip loop" with the mains cable
below the socket. This prevents water from
running along the cable into the socket.
3. To switch ON the water pump: insert the power
supply plug in the socket.
4. To switch OFF the water pump: pull out the plug.

7
UK
MAINTENANCE
Clean the water pump/replace the impeller
NOTE
Do not use chemical cleaning agents as these
can be harmful to your plants and the environ-
ment.
• Only use clean water or special cleaning
products for aquaria.
The water pump must be cleaned regularly. Pull
out the plug and remove the water pump from
the aquarium. If the impeller in the pump is worn,
replace it.
Fig. F
1. Remove the pump housing from the motor body.
2. Remove the impeller and clean it with a soft
brush or replace it.
3. Perform the procedure in reverse order to
reassemble the water pump.
TROUBLESHOOTING
If you are unable to rectify any faults yourself,
contact your local retailer or Tetra Customer
Service.
Malfunction Cause Solution
Pump will not
operate Pump is not
receiving power Connect the power
supply
Pump is faulty Contact your retailer or
Tetra Customer Service
Blocked impeller Clean the pump
Insucient flow
of water Pump is clogged
up Clean the pump
Pump is faulty Contact your retailer or
Tetra Customer Service
Worn impeller Replace impeller

8WP300 / WP600 / WP1000
UK
DISPOSAL
The WP 300 / WP 600 / WP 1000 contains
electronic components and cannot be disposed of
with standard household waste.
• Dispose of the device using the return system
for your area so that the raw materials can be
recycled.
• Cut o all cables prior to disposal to prevent the
device from being used.
TECHNICAL SPECIFICATIONS
WP 300 WP 600 WP 1000
Mains voltage 230 230 230 V AC
Rated mains frequency 50 50 50 Hz
Power consumption 5 11 25 W
Max. flow rate 300 600 1000 l/h
Max. head height
delivery 0.5 1.3 2.0 m
Protection rating IP X8 IP X8 IP X8
Max. immersion depth 1 1 1 m
Recommended for
aquaria 10 - 80 80 - 200 200 - 300 l
Length of mains cable 1.5 1.5 1.5 m
Weight 0.18 0.34 0.54 kg
WARRANTY
Thanks to state-of-the-art production technology,
premium-quality components and stringent quality
controls, the WP 300 / WP 600 / WP 1000 comes
with a two-year warranty from the purchase date.
Please save your receipt. The guarantee does not
cover the following wearing parts:
• Impeller
The warranty shall not apply in the event of im-
proper handling, standard wear and tear or inter-
ference with the device technology. Your statutory
warranty claims remain unaected. In the event of
complaint, please contact your retailer or Tetra:
Tetra Technical Support Centre, Postfach 1580,
49304 Melle, Germany
Spare parts are available from the Tetra GmbH
Service Centre at www.tetra.net.

9
D
WARNUNG
• Dieses Gerät kann von Kindern
ab 8 Jahren und darüber sowie
von Personen mit verringer-
ten physischen, sensorischen
oder mentalen Fähigkeiten
oder Mangel an Erfahrung und
Wissen benutzt werden, wenn
sie beaufsichtigt oder bezüglich
des sicheren Gebrauchs des
Gerätes unterwiesen wurden
und die daraus resultierenden
Gefahren verstehen.
• Kinder dürfen nicht mit dem
Gerät spielen.
• Reinigung und Benutzer-War-
tung dürfen nicht von Kindern
ohne Beaufsichtigung durchge-
führt werden.
• Alle Geräte im Aquarium aus-
schalten oder den Netzstecker
ziehen, bevor Sie in das Wasser
greifen.
• Gerät nicht verwenden, wenn
elektrische Leitungen oder
Gehäuse beschädigt sind.

10 WP300 / WP600 / WP1000
D
SICHERHEITSHINWEISE
Gefahrensituationen für Personen vermeiden
• Schließen Sie WP 300 / WP 600 / WP 1000 nur
an eine fachgerecht installierte Steckdose an.
• Schließen Sie WP 300 / WP 600 / WP 1000 nur
ans Netz an, wenn die örtliche Versorgungs-
spannung mit den Angaben in den Technischen
Daten übereinstimmt.
• Schützen Sie den Netzstecker vor Feuchtigkeit.
• Trennen Sie die Wasserpumpe immer vom Netz,
bevor Sie sie reinigen oder Wartungsarbeiten
durchführen.
• Lassen Sie Kinder nicht mit Kleinteilen spielen.
Es besteht Erstickungsgefahr.
• Der Netzstecker muss frei zugänglich sein,
damit Sie die Wasserpumpe im Notfall einfach
und schnell vom Stromnetz trennen können.
• Nehmen Sie niemals technische Änderungen
am Gerät vor.
• Eine beschädigte Anschlussleitung kann nicht
ersetzt werden. Gerät entsorgen.
Sachschäden vermeiden
• Knicken oder quetschen Sie nicht die Netzan-
schlussleitung.
• Nur Original-Ersatzteile und -Zubehör verwen-
den.
Symbole auf dem Gerät beachten
Nicht mit dem normalen Hausmüll ent-
sorgen, sondern der Wiederverwertung
zuführen.
Schutzklasse II: Metallteile, die im
Fehlerfall Spannung führen können, sind
schutzisoliert.
Ausschließlich in Innenräumen ver-
wenden.
ZU DIESER ANLEITUNG
Die Anleitung gehört zum WP 300 / WP 600 /
WP 1000 und muss aufbewahrt werden.
Other manuals for WP 300
1
This manual suits for next models
2
Table of contents
Languages:
Other Tetra Water Pump manuals
Popular Water Pump manuals by other brands

Sykes AmeriPumps
Sykes AmeriPumps GP100M Operation and maintenance instructions

DUROMAX
DUROMAX XP WX Series user manual

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 operating instructions

Franklin Electric
Franklin Electric IPS Installation & operation manual

Xylem
Xylem e-1532 Series instruction manual

Milton Roy
Milton Roy PRIMEROYAL instruction manual