Tebas BP-100HS-A Product manual

Directions for installation and maintenance

2
contents
1. Introduction ………………….…………………………….……..………….
p3
2. Caution…………………………………………………….………………….…..
p3
3. Delivery control …………………………………………........................
p4
4. Technical description ……………………….…………………………..
p4
Technical characteristics
Outside
Inside
BP-100HS-A explored view
Wire control operation
General diagram of the refrigerating circuit
Safety and control systems
Electric diagram
5. Installation ……………………….………………………………….......
p14
Rules of installation
Hydraulic connections
Electric connections
Procedure of use
6. Water flow and refrigerating circuit pressure........................
p18
7. Defrosting ……………………………………………………………………
p19
8. Environment problem ………………………………………............
p19
9. Error messages and what to do ………………………………..…
p20

3
1- Introduction
We thank you for having chosen our Heat pump.
This installation and maintenance notice contains the necessary
information to its installation (delivery control, the installation, the
connections) and to its repair. It is a complementary document to the
user’s manual which describes its instructions for use.
We invite you to read it first.
2-
Caution
This document is an integral part of the product and it must stays in
the technical room.
This Heat pump is exclusively for heating swimming pools.
Any other use not in conformity and random will be considered as
dangerous and unsuitable.
The assembly, the electric connection and the start up must be
carried out by specialized and professional person.
When connect to socket (power supply), please make sure that live
wire, neutral wire, earth wire is right.
It is essential to maintain the temperature in the swimming pool lower
than the recommended value by the swimming pool’s manufacturer.
Please make sure that minimum water flow speed is 5m³/h.
In a concern to a constant improvement, our products can be modified
without notice; the present pictures in this note or the characteristics
which are described are not contractual.

4
3- Delivery’s control
At the delivery time, check the condition of packing; in case of
damages, have reservation about them to the carrier, before 48 hours
and by registered letter with acknowledged receipt.
Before any manipulation, check the complete state of the machine.
4
-
Technical description
Characteristics:
MODEL BP-100HS-A
Power supply 230V~, 50Hz
Heating consumption power * (kW) 2.05
Heating restored power *(kW) 10.5
Heating nominal intensity *(A) 9.5
Cooling absorptive power * (kW) 2
Cooling restored power *(kW) 8
Cooling nominal intensity *(A) 9
Air flow (m3/H) 2400
Noise level (d(B)A) <53
Refrigerant gas R410a
Rate of average filling of gas (g) 1100
Net weight of the unit (kg) 61
Overall sizes L x W x H (cm) 100 x 30 x 57
*
Possible variations of value according to climatic conditions

5
Outside:
Inside:
(Front sheet cover and panel removed)
1 Fan protection grid
2 Front panel
3 Top cover
4 Control panel
5 Refrigerant pressure manometer
6 Fast connection for water outlet
7 Fast connection for water intlet
8 Wire connection for power supply
9 Evaporator
10
Fan
11
Compressor
12
High and low pressure interruptor
13
Titanium heat exchanger
14
Temperature sensor of swimming pool water
15
Four way valve
16
Ambient temperature sensor
17
Defrost sensor
18
Water flow switch

6

7
Wire control operation
The function of the LED display and control:
Set the operation parameter:
When the unit powered up but not running, press " " or " " to enter operation parameter
interface. (parameter from 0-F, see Operation Parameter Table).
◎Press "SET" to enter current parameter setting, press " " or " "to set data for
parameter, press "SET" again exit the current parameter setting.
◎No press in 8s, it will exit the setting interface.
◎If the heat pump is running, press " " or " " to enter operation parameter check
interface, But can’t change parameters (Except the parameter 0, 1, 2 for water temperature
setting in different modes).
◎If the heat pump is running, the LED display shows current water temperature;
If the heat pump is turnoff, the LED display shows current time.
NO
Meaning
Range
Change
Factory setting
0 Cooling setting water temperature 15~45°C YES 27
1 Heating setting water temperature 15~45°C YES 27
2 Auto mode setting water temperature
15~45°C YES 27
3 Turnround of defrosting Under heat
mode 30 ~ 90 min YES 40 (40 min)
4 Defrosting start temperature -30 ~ 0°C YES -5°C
5 Defrost exit temperature 2 ~ 30°C YES 15°C
6 Time of exit defrost Under heat mode
0 ~ 12 min YES 6 min
7 Low ambient temperature protection
-20~10°C YES -7°C
8 Compressor protection
Exhaust temperature 95 ~ 110°C YES 95°C
9 Automatic restart 0/1 YES 1
A Mode (heat/coo & heat) 0/1 NO 1
b Water pump mode 0/1 YES 1
C Water temperature difference to
restart 1 ~ 10°C YES 2
d Water temperature -9 ~ 99°C Measured value
E Compressor Exhaust temperature -9 ~ 125°C Measured value
F Copper temperature -9 ~ 99°C Measured value
H Ambient temperature -9 ~ 99°C Measured value

8
Choose the operation mode:
◎Press “ ” to power on unit. Under running, the LED displays the water temperature and
current mode.
◎Press “ MODE ” to choose mode(mode can be changed under running)
◎ Press " " or " " to enter operation parameter check interface, Select the current mode
water temperature setting parameters, press "SET" button to enter, press " " or " " set
required tempreature.
◎Stop for 3-4 minutes, reverse of cycle and restart in a new mode.

9
Check current temperature:
◎Under running, press " " or " " to check the current status of the unit. You can check
water/ambient/compressor/copper temperature.
Setting the time
press “CLOCK” botton to set the time. The time displayed blinks, press “CLOCK” botton again
and then use the arrow " " and " " to change the hour setting. To change the minutes,
press “CLOCK” botton again. Once the correct time is set. press “CLOCK” botton again the end.
The display returns to normal after 8 seconds.
Timer switch ON and Timer switch OFF:
Once the time has been set correctly, this function allows a machine start time and a machine stop
time to be programmedduring the day.
Press “TIMER ON” botton the time displayed and “ON” to blink, press “TIMER ON” botton again
Change the hour using the " " and " " keys. Press “TIMER ON” botton again to change
the minutes using the " " and " " keys. Press “TIMER ON” botton again the end.
Press “TIMER OFF” botton the time displayed and “OFF” to blink, press “TIMER OFF” botton
again Change the hour using the " " and " " keys. Press “TIMER OFF” botton again to
change the minutes using the " " and " " keys. Press “TIMER OFF” botton again the end.
The time setting is from 0 to 24 hours to recycle.
When the setting time for on and off is the same,the setting time is not available.
When the setting timer, Press “CLOCK” to deactivate TIMER.
Coercive Defrosting (Only on heating mode):
1. Press “ MODE ” 10 seconds when the unit is running, the unit will go into coercive defrosting
function.
2. When it arrives in defrosting exit criteria, defrosting is stopped.
3. After exiting the defrosting, the unit will stop 30 seconds, then it will heat water again.
Key lock:
Press "SET" and " " 5 seconds to set keylock.
Press "SET" and " " 5 seconds again to release keylock.

10
General diagram of the refrigerating circuit
The heat pump is reversible allowing the swimming-pool’s heating or
cooling:
Swimming-pool water’s heating mode:
The cold and liquid refrigerant fluid absorbs the heat contained in the air through the evaporator
(gilled radiator), in which it is vaporizing; it is then put up in pressure and in temperature by the
compressor which sends it in the condenser (exchanger) where it loses its heat (in giving it to the
water of swimming pool) and comes back in liquid state; it loses its pressure and still cools in the
expansion capillaries before turning back to the evaporator for a new cycle.
Hot water
Cold water
Hot air
Cold air
Compressor
S
ingle
way
valve
Condenser
(exchanger)
4 way valve
Pressure and gas
intake
Evaporator
(gilled
radiator)
Expansion
capillary
Table of contents
Other Tebas Heat Pump manuals
Popular Heat Pump manuals by other brands

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Service manual

Dimplex
Dimplex LI 16I-TUR Installation and operating instruction

Carrier
Carrier WSHP Open v3 Integration guide

TGM
TGM CTV14CN018A Technical manual

Carrier
Carrier 38MGQ Series installation instructions

Kokido
Kokido K2O K880BX/EU Owner's manual & installation guide

Viessmann
Viessmann VITOCAL 300-G PRO Type BW 2150 Installation and service instructions

Carrier
Carrier 48EZN installation instructions

Viessmann
Viessmann KWT Vitocal 350-G Pro Series Installation and service instructions for contractors

Ariston
Ariston NIMBUS user manual

Weishaupt
Weishaupt WWP L 7 Installation and operating instruction

GE
GE Zoneline AZ85H09EAC datasheet