TCS ISH3230 User manual

TCS TürControlSysteme AG Subject to technical changes.
Product information
Door telephone
with announcement function
ISH3230

2 08/2012
TCS TürControlSysteme AG Subject to technical changes.
Table of contents
Scope of delivery...............................................................................................................3
Safety instructions.............................................................................................................3
Installation –protective measures....................................................................................3
Intended use.......................................................................................................................3
Max. number of ISH3230 in 3-wire operation...................................................................4
Indication and operating elements...................................................................................4
Device overview.................................................................................................................5
Technical data....................................................................................................................5
Short description...............................................................................................................6
Installation..........................................................................................................................6
Open the device...............................................................................................................8
Installation of extended functions.....................................................................................8
Connect the lines...............................................................................................................9
Connection lines...............................................................................................................9
Wiring example.................................................................................................................9
Connection diagram 3-wire technique............................................................................10
Replace an ISH1030 or TTS1 with an ISH3230.............................................................10
Commissioning................................................................................................................10
Settings.............................................................................................................................10
Preset times ...................................................................................................................10
Ring tone selection.........................................................................................................11
Adjust volumes...............................................................................................................11
Configuration options .....................................................................................................12
Programming with the Service Device TCSK-01............................................................12
Configur groups..............................................................................................................12
General information to the conduit in TCS audio systems..........................................13
Principle loop resistance.............................................................................................13
Measurement loop resistance.....................................................................................13
Repair................................................................................................................................14
Fault detection and indication.........................................................................................14
Exchange an indoor station –programming bell buttons................................................14
Cleaning............................................................................................................................15
Conformity........................................................................................................................16
Entsorgungshinweise......................................................................................................16
Warranty...........................................................................................................................16
Spare parts, accessory....................................................................................................16
Service..............................................................................................................................16

08/2012 3
TCS TürControlSysteme AG Subject to technical changes.
Scope of delivery
1 x Indoor station ISH3230: upper cover, lower cover, handset with handset cord
Product information
Instruction manual
Safety instructions
!
Attention! Installation, mounting, commissioning and repair of electrical devices has to
be carried out only by qualified electricians, The current standard for the installation of
door communication systems must be observed!
When installing TCS:BUS systems, the general safety regulations for telecommunication
systems according to VDE 0800 must be observed. Inter alia:
separated cabling of heavy and low current lines,
minimum distance of 10 cm for common cabling,
use of separators between heavy and low current lines in shared cable ducts,
use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter,
existing lines (modernisation) with deviating cross sections can be used in compliance
with the loop resistance.
Installation –protective measures
!
With suitable requirements to protect against lightning, it has to be ensured that a volt-
age of each 32 V DC is not exceeded at the connections a, b, P, E.
Intended use
ISH3230 are door telephones for duplex communication with handset for the TCS:BUS.
They are suitable for the operation in TCS audio systems and combined audio / video
systems in the object area.
They are suitable for surface-mount (installation via flush-mounted socket) or desktop
mount with desktop accessory ZIT3030-0010.
3-wire technique necessary!
!
The indoor station ISH3230 must not be used in call systems according to DIN VDE
0834 and EN50134.
According to DIN 77800, a separate safeguard for emergency call has to be in-
stalled.
A system equipped with an indoor station ISH3230 is not an emergency call system
according to the above mentioned standards.
The indoor station ISH3230 must not be used in life-saving or life-sustaining sys-
tems.
Further the combination of system parts which fulfill the above mentioned standards
is not permitted.

4 08/2012
TCS TürControlSysteme AG Subject to technical changes.
Max. number of ISH3230 in 3-wire operation
when using power supply
and control unit
max. number
ISH3230
NBV3210, 3 lines
30
VBVS05 (PSG02), 1 line
10
AS front-door station
VS power suply and control unit
IS indoor station
Note: The number of front-door stations which can be connected is limited. Details are described in respective product
information!
Indication and operating elements
handset
speaking to the door
end speaking
call OFF button
shortly press: ring tone stopper
press for 8 sec: initiate ring tone selection
indication call OFF
(red)
is ON: call OFF is activated
fault indication: both LEDs flash
ring tone selection: both LEDs are ON
○
control key
control function 8
ring tone selection internal call
call indication
(green)
is ON: call, speaking is activated
blinks 3 x: voice channel is busy
fault detection: both LEDs flash
ring tone selection: both LEDs are ON
light button
switch lights
ring tone selection floor call (from the flat door)
door release button
open the door
trigger light switch function (if the light switch function is
activated at the front-door station)
ring tone selection door call from the front-door station
volume control for
voice output and
ring tone
adjustable in 8 steps:
when voice communication is established
when the handset is cradled (no voice communication)

08/2012 5
TCS TürControlSysteme AG Subject to technical changes.
Device overview
Technical data
supply voltage: +24 V ±8 % (power supply and control unit)
housing: plastics white
dimensions (in mm): H 204 x w 100 x D 50
weight 340 g
acceptable ambient temperature: -5 ...+ 40 °C
degree of protection: IP30
input current in stand-by I(a) = 0.2 mA, I(P) = 1 mA
max. input current: I(Pmax) = 70 mA
3-wire technique necessary!
handset
call indication (green)
indication call OFF (red)
call OFF button
light button
control key
ring tone loudspeaker
door release button
volume control
handset connection cord

6 08/2012
TCS TürControlSysteme AG Subject to technical changes.
Short description
large, deteched, blue door release button
light switch button
function key (fixed assignment with control function 8,alternate allocation can be acti-
vated: internal call, door release automatic, call diversion)
call OFF button for ring tone mute with optical indication
optical indication of door calls via LED (green)
optical display of a busy line when voice communication is established LED (green)
ring tones can be adjusted by residents, selection of 13 ring tones with improved quality
voice volume and ring tone volume can be adjusted in 8 steps by the user
acoustic call distinction between 2 front-door stations (via configuration software confi-
go™), flat door (floor door) and internal call
a parallel call can be activated (via Service Device TCSK-01 or configo™)
audio privacy function and automatic call cut-off
magnetic handset cradle
pluggable handset cord
lower cover with pined screw terminal can be pre-installed and can be equipped alterna-
tively with sister product for hands-free talking
optical (and acoustic) error indication
can be functional extended due to mounting places for call relays, activation radio sig-
nal device and EnOcean radio interface
energy-efficient due to low stand-by consumption of only 0.025 W
reproduction of loud tones and announcement is possible (also when the handset is on-
hook and the ring tone switched OFF)
Installation
Install lower cover
For placing the connection cables without any
problems, a flush-mounted socket must be in-
stalled behind the device.
Position the flush-mounted socket below the
cable conduit.
Install the lower cover with three screws.
TIPP: Avoid tearing of the straps:
For fixing at the straps do not use counter-head screws
rather use flat washers!

08/2012 7
TCS TürControlSysteme AG Subject to technical changes.
Connect the lines
Minimize the length of the lines above the
lower cover to place the lines without any
problems and do not clamp the lines when
snapping-on the upper cover.
Connect the lines according to the labeling: a
b E P (from the button to the top), floor push
button at a –E.
Wiring example see page 9.
Snap-on the upper cover
Set on the upper cover at both adjustment
increments of the lower cover (1).
Snap-on the upper cover below with slight
pressure (2)
Connect the handset
Plug the western connector of the handset
cord into the socket at the underside of the
telephone.
1
2
floor push button

8 08/2012
TCS TürControlSysteme AG Subject to technical changes.
Open the device
Remove the handset cradle.
There is a rectangular release opening at
the underside of the device. Insert a small
screwdriver straight and with slight pressure
into this opening.
The upper cover can be removed at the
underside (1).
Lift the upper cover out of the two upper
adjustment increments (2).
Installation of extended functions
TRE1*
Radio transmitter
board FFS3100
radio interface FBI4200
The extended functions (and the antenna) have to be fixed in the indoor station with
adhesive pads (see also product information of each extended function).
* Connecting the lines is realised in analog to the ISH3030 (see product information TRE1-EB/1).
1
2

08/2012 9
TCS TürControlSysteme AG Subject to technical changes.
Connect the lines
Connecting lines
acceptable cross-section (diameter)
0.08 … 0.82 mm2(Ø 0.32 … 1.0 mm)
max. number of wires per terminal contact
each 2 x 0.8 mm, 3 x 0.6 mm
!
Further wires have to be connected with auxiliar terminals!
!
Use only connecting lines with identical diameter in one terminal contact.
Wiring example
floor push
button
floor push
button

10 08/2012
TCS TürControlSysteme AG Subject to technical changes.
Connection diagram 3-wire technique
Replace an ISH1030 or TTS1 with an ISH3230
The floor push-button always has to be connected to the a-wire.
In case of a parallel connection, both telephones must be replaced by an ISH3230.
Commissioning
Install the devices of the system voltage-free and completely.
Check the a-, b- and P-wire against each other for short-circuits.
Switch on the mains voltage.
Note:
If the floor push button does not work, check if it is connected to the a-wire of the power
supply and control unit.
Settings
Preset times
communication time
2 min
flashing period of the green LED, if the voice
channel is busy after lifting the handset
2 sec
3 x flashing
internal stand-by time, if the device is calling
or is called
around
30 sec
Table of contents
Other TCS Intercom System manuals

TCS
TCS AMI Series User manual

TCS
TCS ECOOS:FIVE User manual

TCS
TCS ISW3130 User manual

TCS
TCS Tasta Series User manual

TCS
TCS PVE14 0-0010 Series User manual

TCS
TCS AMI Series User manual

TCS
TCS AVU14 0 Series User manual

TCS
TCS ISH3030 Instruction manual

TCS
TCS ISH3030-0140 User manual

TCS
TCS VPES Series User manual

TCS
TCS Tasta Series User manual

TCS
TCS IVH3222 User manual

TCS
TCS Carus Origo User manual

TCS
TCS AVD Series User manual

TCS
TCS SKYLINE:TEN BASIC User manual

TCS
TCS IVW9011-0261 User manual

TCS
TCS IMM2500 User manual

TCS
TCS PSC2120-0000 User manual

TCS
TCS ISH3230-0140 User manual

TCS
TCS IVX9001-0140 User manual