Swisson XRC-CT15b User manual

XRC-CT15b
External Trigger
Contacts for XRC-
150/200
User Manual

2
XRC-CT15b External Contacts Trigger for
XRC-150/200
User Manual
Issue 1 (2011-05-31)
Copyright © 2011 SWISSON AG
No part of this documentation may be reproduced
or transmitted in any form or by any means,
electronic or mechanical, including photocopying
and recording, without the prior written permission
of SWISSON AG.
The information in this documentation is supplied
without warranty of any kind, either directly or
indirectly, and is subject to change without prior
written notice. SWISSON its employees or
appointed representatives will not be held
responsible for any damages to software,
hardware, or data, arising as a direct or indirect
result of the product(s) mentioned herein.
Issued by
SWISSON AG
Fabrikstrasse 21
CH-3250 Lyss
Switzerland

3
Table of contents
Table of contents ............................................ 3
Overview......................................................... 4
General Description........................................ 5
Connecting the XRC-CT15b to the XRC-
150/200........................................................... 6
Connection .................................................. 6
Connecting Cable........................................ 7
Opening the XRC-CT15b ............................... 8
Connecting contacts to the XRC-CT15b ........ 9
Using internal Power ................................... 9
Using external Power .................................. 9
Configuration of the XRC-150 ...................... 10
Configuration of the XRC-200 ...................... 10
Technical Data.............................................. 12
Absolute Maximum ratings........................ 12
Operating Conditions ................................ 12
Safety notes.................................................. 14

4
Overview
1
2
3
4
1 Port Connector
The XRC-CT15b is connected with
the XRC-150/200 through this port.
2 Cable Glands
Glands for cables connected in the
XRC-CT15b
3 Lid
The lid of the XRC-CT15b can be
removed for connection of the
contacts
4 Lid Screw
This screw holds the lid on the XRC-
CT15b

5
General Description
The XRC-CT15b is an accessory for use with the
XRC-150/200. On this device up to 15 external
trigger contacts can be connected.
With these contacts the XRC-150/200 can be
controlled remotely:
Each button can be configured to start, stop or
pause, play back of a sequence on the XRC-
150/200.
Contacts 1 .. 15
XRC-CT15b
XRC-150

6
Connecting the XRC-CT15b to
the XRC-150/200
Connection
The XRC-CT15b can be easily connected to the
XRC-150/200 through running a cable from the
external port of the XRC-200 or from one of the two
external ports of the XRC-150 to the XRC-CT15b:
It doesn’t matter on which port (port #1 or #2) the
XRC-CT15b is connected to the XRC-150.

7
Connecting Cable
The connection of the XRC-CT15b to the XRC-
150/200 is done with a standard RJ45 8 pole
STRAIGHT network cable:
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
The speed of the data transmission between the
XRC-CT15b and the XRC-150/200 is 250 kBaud.
Therefore, the cable mustn’t be very high quality.

8
Opening the XRC-CT15b
To connect the XRC-CT15b with external trigger
contacts, the lid must first be removed. Simply
remove the lid screw:
Lid Screw
Slide out the lid of the XRC-CT15b:
Now you can see the connecting ports (1 – 15) for
the external trigger contacts and also two
connectors of the internal power (VCC and GND):

9
Connecting contacts to the
XRC-CT15b
Using internal Power
Using the internal power of the XRC-CT15b is a
very simple way to connect external trigger contacts
to the device.
Simply connect a switch, button, relay or another
contact with one connection to the internal supply
voltage (VCC) of the XRC-CT15b, and the other
connection to a dedicated input of the device:
Using external Power
When using external power, it’s necessary to
connect GND of the XRC-CT15b to the voltage
reference (ground) on the external device:
ATTENTION:
When using external power, you have to take
attention to the maximum ratings!!! (See chapter
Absolute Maximum ratings on page 12)
VCC
1
2
15
XRC-CT15b
Voltage of
external device
1
2
15
Reference (Ground
of external device
GND
XRC-CT15b
External Device

10
Configuration of the XRC-150
Every time a contact is activated, the XRC-CT15b
sends this information to the XRC-150.
Therefore it’s possible to configure each contact
activity on the XRC-150 to either start, stop or
pause, a sequence.
To configure the contacts, go to the menu point
EXTERNAL DEVICES in the XRC-150 main menu
and press the confirm/select button. Now scroll
to CONTACTS CONFIGURATION and press the
confirm/select button again. The following will
appear on the display of the XRC-150:
Now you need to choose the contact by activating
it. For example if you have connected a switch on
contact1, press this switch to configure contact1:
There are three different possible actions:
1. Play Sequence:
This will start playback of one of the 32
different sequences (the sequence can be
set)
2. Pause:
This will set the XRC-150 to pause or
release the XRC-150 from pause during
playback.
3. Stop:
This will stop the XRC-150 during play
back or recording.
Configuration of the XRC-200
In order to configure the XRC-200’s behavior upon
events triggered by an XRC-CT15b, open the XRC-
200’s menu and select ADVANCED, confirm by
Table of contents
Popular Lighting Equipment manuals by other brands

Qazqa
Qazqa Suplux SL 3 Black 103062 instruction manual

Commercial Electric
Commercial Electric 54568141 Use and care guide

CREE LIGHTING
CREE LIGHTING 304 Series installation instructions

Goobay
Goobay 49867 user manual

ECOMAN ITALIA
ECOMAN ITALIA LED T8 instruction manual

Alkalite
Alkalite Krypton KT-81 user manual