SUNSCAN SunSmart SSD-0360410A User manual

Air to Water Heat Pump
Installation &Operation Manual
Retain this document for future referencece.
AGuide to the installation and operation of SunScan SunSmart Air to water Heat pumps.
Please read this manual carefully before installing and operating the Heat pump
Model Number :SSD-0360410A
SSD-0540410A
SSD-0900410A
SSD-0132410A


- 1 -
Introduction
Congratulations on purchasing a SunScan SunSmart Heat pump, our Heat pumps
use cutting edge technology and attractive design to bring you a high quality
product.This manual must be read thoroughly and understood before undertaking to
install any of the SunScan range of heat pumps, please note that this manual is
specific to the product/s listed or described on the cover page. If after reading this
manual any aspect of the installation process remains unclear contact a SunScan
representative prior to installation.
This manual serves only as a guide to the correct installation of SunScan
components; it does not seek to defy logic and or the experience of suitably trained
installers, use discretion within the parameters of the below standards.
SunScan water heating apparatus must be installed in compliance with the
following:
SANS 198, SANS 10252 -1, SANS 10254, SANS 1352, SANS 60335-2-21
SANS 10400 – parts A, B, L, XA, SANS 10142-1
No modifications from these standards are allowed. All local bylaws and estate laws
must also be adhered to.Failure to comply with any or all of these standards may
result in injury or death and may void the warranty.Any attachment, connection,
integration or general association of parts or components that
directly or indirectly affect the operation or performance of a SunScan product
could void the warranty. Such parts not supplied by SunScan must be authorised by
SunScan in writing in order to retain the benefits of the warranty.
SunScan does not accept responsibility for the final fitness of the water for
consumption, as the water quality is not affected by the heat pump.

- 2 -
Codes and Standards
Important Notice:
IMPORTANT SAFETY PRECAUTIONS
Attention Installer: This guide contains important information about the
installation, operation and safe use of this product. This information should be
given to the owner and/or operator of this equipment after installation.
Attention User: This manual contains important information that will help you in
operating and maintaining this product. Please retain document for future
reference.
WARNING -This manual must be read thoroughly and understood
before undertaking to install any of the SunScan range of heat pumps.Failure to
follow safety warnings and instructions may result in severe injury, death,or
property damage.
WARNING - This water heater is not intended to be operated or adjusted by young
children, the elderly, infirmed or physically/mentally handicapped persons.
SunScan water heating apparatus must be installed in compliance with the
following:SANS 198, SANS 10252 -1, SANS 10254, SANS 1352, SANS 60335-2-21
SANS 10400 – parts A, B, L, XA, SANS 10142-1
No modifications from these standards are allowed. All local bylaws and estate lawsmust
also be adhered to. Failure to comply with any or all of these standards may void the
warranty.
DANGER — Risk of electric shock
The electrical supply to this product must be installed by a licensed and
certifiedelectrician in accordance with the National Electrical Code and all
applicablelocal codes and ordinances. Improper installation will create an
electrical hazard which could result in death or serious injury to heat pump
users, installers orothers due to electrical shock, and may also cause damage
to property. Readand follow the instructions inside this guide.

- 3 -
What's in the box?
9
Heat Pump Unit 1
No. Name Qty.
1 Installation &Operation Manual 1
2 Wire-controller 1
3 Wire-controller sensor wire 1
4Wire controller box & pad (plastic) 1
5Power cable (selected models) 1
6Drain-pipe 1
7Drain-pipe connector 1
8Rubber shock absorber 4

- 4 -
Please read the manual carefully before operation and keep it for future reference.
Content
Initial Operation...................................................................................19
Operation And Maintenance............................................................20
Technical Parameter.......................................................................... 21
Operating Instructions......................................................................14
Installing Electrical Components...................................................12
Installing The Water Pipes..............................................................10
Installing The Unit...............................................................................9
How Heat Pumps Work.................................................................... 8
General Safety..................................................................................... 5
Warranty...............................................................................................21

- 5 -
Range of application:
1. Power supply: 230V/1N~50Hz.
2. Environment temperature: -7°C〜43°C :
The power supply to the unit must be grounded.
NOTICE
General Safety
Theheat pump has a anti-freezing operation. In winter when the ambient is below
0℃,the unit will start automatically to keep water from freezing, this protectsthe unit
andwater piping system. DO NOT switch the unit off or disconnect it from the power
supply during low ambient (0°C) times.
If the unit is not in use for extended periodsin winter when the ambient temperature is
below 0℃, theuser can switch off the unit and disconnect it from the power supply,if all
water is discharged from the heat pump and piping system. Failure to discharge water from
the heat pump before switching off or disconnecting the power supply may result in damage
to the unit or piping system.
Please read the below precautions carefully to avoid damage to the unit and/or harm to
the user
The installation, dismantlement and maintenance of the unit
must be performed by qualified personnel. DO NOT make any
changes to the structure of the unit.

- 6 -
Use a dedicated socket outlet / circuit for this unit.
Keep the unit away from other home appliance or heat sources,
this preventsany possible magnetic interferance and ensures
the unit'sperformance.
Do not touch the power plug or any electrical components with
wet hands. Never pull theplug out by pulling on the
power-cable.
Never cover the unit with clothes,plastic or any other material
that may block ventilation of theunit,this will lead to low
efficiency or non-operation of this unit.
Coil fins are sharp and may cut fingers
Never pour water or liquid into or over the unit.

- 7 -
Do not touch the air outlet grill when fan motor is running
Please ensure the power supply is switched off before any
maintenance / cleaning works.
Always select the correct fuse or breaker. Steel wire or copper
wire cannot be used as a substitute for fuse or breaker.
Keep the unit away from combustible or corrosive
environment.
It is mandatory to use a suitable circuit breaker for the heat
pump and make sure the power supply to the heater
corresponds to the specifications.
The minimum inlet water pressure should be 0.1MPa and
maximum pressure 0.7MPa.

- 8 -
4 way valve-
water inlet
water outlet
condenser
liquid gas seperator- compressor
filter
expansion valve
filter
evapo rator
f an
Figure 1
Qc (Heat energy get) =Qa (Compressor consumption) +Qb (Heat energy absorbed from ambient environment)
How heat Pumps work
Heat pumps transfer heat by circulating refrigerant through a cycle of evaporation and condensation. A
compressor pumps the refrigerant between two heat exchanger coils. In one coil, the refrigerant is
evaporated at low pressure and absorbs heat from its surroundings. The refrigerant is then compressed
en route to the other coil, where it condenses at high pressure. At this point, it releases the heat it
absorbed earlier in the cycle.
1. Heat pump process
2. Air source heat pump diagram
This manual suits for next models
3
Table of contents
Popular Heat Pump manuals by other brands

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Service manual

Dimplex
Dimplex LI 16I-TUR Installation and operating instruction

Carrier
Carrier WSHP Open v3 Integration guide

TGM
TGM CTV14CN018A Technical manual

Carrier
Carrier 38MGQ Series installation instructions

Kokido
Kokido K2O K880BX/EU Owner's manual & installation guide

Viessmann
Viessmann VITOCAL 300-G PRO Type BW 2150 Installation and service instructions

Carrier
Carrier 48EZN installation instructions

Viessmann
Viessmann KWT Vitocal 350-G Pro Series Installation and service instructions for contractors

Ariston
Ariston NIMBUS user manual

Weishaupt
Weishaupt WWP L 7 Installation and operating instruction

GE
GE Zoneline AZ85H09EAC datasheet