Model Number : YC-050TA1
Thank you very much for purchasing our product, please keep and read this manual carefully before you install heat
pump.
Packing List

- 2 -
No.
Name
Qty.
Photos
1
Installation & Operation Manual
1
2
Wire-controller
1
3
Heat exchanger connector
2
4
Wire-controller signal wire
1
5
Heat Pump Unit
1

- 3 -
Please keep installation manual properly, and read it carefully before using.
The unit must be installed by professional personnel, and install it based on this manual as
possible.
Special reminding: if the unit would be installed where is vulnerable to lightning stroke, lightning
protection measurements must be carried out.
Special reminding: The unit is not suitable for using in the Winter (< -7 °C), when the unit leave
unused in Winter, the water reserved in the pipe network system must be drained.
Content
1. Accessories Description.......................................................................................4
2. Attention for safety.................................................................................................4
3. Heat pump unit working principle......................................................................6
4. Installation of the unit............................................................................................7
5. Installation of the pipeline..................................................................................10
6. Installation of optional accessories................................................................ 12
7. Installation of electric devices.......................................................................... 13
8. Instruction of operation...................................................................................... 17
9. Adjusting and Initial operation......................................................................... 26
10. Operation and maintenance............................................................................ 27
11. Fault analysis and elimination method........................................................29
12. Technical parameter.......................................................................................... 30

- 4 -
1. Accessories Description
Each unit produced by our factory with the following accessories:
For function you need to purchase at least the following parts for each unit:
No.
Name
Qty.
use
1
Water circulation pump
Drive the water cycle
2
Swimming pool filter system
Protect the heat pump heat exchanger and pipes
3
Water pipe and valves
Connect the equipment and make circulation
NOTE
The types and quantity of the water pump, filters, pipes and water tank, refer to the real project design.
We do not suggest to install auxiliary electric heaters in the system, if must install auxiliary electric
heaters, should install the electric heaters by the specialized persons, and our company has no
responsibility for all the problem cause by the auxiliary electric heater.
2. Attention for safety
Range of application:
1.Power supply: 380V/3N~50Hz.
2.Environment temperature: -7°C〜43°C :
3.Working water temperature: Min. inlet water temperature 8°C, Max. outlet water
temperature 40°C. If the system is always used beyond the available water range,
please contact with the local agent.
●The installation shall be done by the professional persons, to prevent leaking, electric shock, or fire
disaster.
●Confirm the ground connection, if the ground connection is not correctly done, it may cause electric
shock.
No.
Name
Qty.
Use
1
Installation & Operation Manual
1 PC
Guide users to install the system
2
Wire controller
1 PC
Used for the man-machine operation interface
3
Wire controller connecting cable
1 PC
Connect wired controller to heat pump unit
4
Heat pump unit
1 SET
For heating water

- 5 -
●When install the heat pump in a narrow space (equipment room), must keep well ventilated.
●Don't put finger or sticker into the air inlet or air outlet. Because the internal rotor high-speed operation
may cause injury.
●When an exception happens (burning smell), turn off the manual power switch immediately, stop
operating, and contact with after-sale service department. If continue the abnormal operation, it may
cause electric shock or fire disaster.
●When the unit needs to be removed or re-installed, please entrust after-sale service department and
specialized personnel to do it. If the installation is not well done, it may cause unit operation failure,
electric shock, fire, hurt, leaking, etc.
●Must not be unauthorized reformed, otherwise it may cause electric shock or fire.
●When needs to be repaired, please entrust after-sale service department or a specialized personnel to
implement. If improper repaired, it may cause unit operation failure, electric shock, fire, hurt, leaking, etc.
●Can not install the unit in combustible gas easy-leaking places, once the combustible gas leaks around
the unit, it may cause a fire.
●Confirm if the installation base is strong enough, if it is not strong and has been used for a long time, it
may cause falling and injuries.
●Confirm if leakage protection switch is installed, if don't install a leakage protection switch, may cause
electric shock or fire.
●When cleaning the unit, the operation should be stopped, and power switch should be turned off.

- 6 -
3. Heat pump unit working principle
3.1 Heat pump working process
● First, the low pressure and superheated gas in the evaporator is inhaled into the compressor then
becomes the high temperature and high pressure overheated vapour.
● Second, the overheated vapour is exhausted into the condenser and exchange the heat with the water,
then the refrigerant is condensed and becomes the saturated or over cooling high pressure and high
temperature refrigerant liquid. The water is heated up by heat pump when absorbing the heat energy
which released by the refrigerant.
● Third, the refrigerant liquid releases the pressure by passing the expansion valve, then becomes the
low temperature and low pressure liquid.
● Fourth, the refrigerant liquid flows into the evaporator and absorb the energy from the air, then is
vaporized and became the low pressure and overheated vapour. The refrigerant working repeatedly as
described above, then the water which flows through the condenser is heated up constantly, the
temperature rise and can get the hot water.
3.2 Air source heat pump working principle
4 way valve
Water inlet
Water Outlet
Condenser
Gas-liquid
separator
Compressor
Filter
Expansion valve
Filter
Ev apor ator
Fan un it
Figure 1
Qc(Heat energy get) =Qa(Compressor consumption) +Qb(Heat energy absorbed from ambient environment)

- 7 -
4. Installation of the unit
4.1 Installation attention
● Avoid installations in such locations with mineral oil.
● Avoid installation in locations where air contains salt or other corrosive gas.
● Avoid installation in locations with serious power supply voltage fluctuation.
● Avoid installation in an unstable place, such as car or cabin
● Avoid installation near flammable items.
● Avoid installation in locations with strong electromagnetic wave.
● Avoid installation in locations with special harsh environmental conditions.
4.2 Installation check
● Check the model, number, name etc, avoid incorrect installation.
● Make sure enough space for installation and maintenance.
● Make sure barrier-free for air inlet and outlet, also dry ventilated place.
● Make sure the bearing surface can meet the requirement and avoid shocks.
● The power supply and its capacity, wire diameter choice should be in accordance with the electrical
installation requirements.
● Electrical installation must comply with the relevant technical standards of electrical equipment, and
electrical insulation work must be done.
● The unit must be power on for at least eight hours before running and debugging.

- 8 -
4.3 Installation space
Keep the following indicated space for operation and maintenance first before installation
Figure 3 Installation space
>1200
>1200
Figure2 The distance to top barrier
>2000
>500
>600
>500
>1200
>500
>500
>600
>1200
Unit: mm
Unit: mm
Unit: mm

- 9 -
4.4 Heat pump unit size
YC-050TA1
Figure 4 Size
Size (mm)
Model No.
L
W
H
YC-050TA1
1410
748
1000
4.5 Reserve the installation base for the heat pump
Please refer to Figure 5.
A n c h o r b o lt
Drainage tray
Heat Pump
Installation base
Concrete
Anchor bolt
Screw nut/washer
Shock absorb
Heat Pump
Drainage tray
Figure 5 Reserved installation base
4.6 Hoisting attention
● Please use four or more soft lifting belts to move the sets Figure 6.
● Please use protective plate on the surface of the sets when moving, to avoid scratch and deformation.
● Recheck whether the foundation is correct before hoisting the unit.
● The heat pump will produce condensation water,please consider the drainage channel when make the

- 10 -
installation base.
● Please put shock absorb on base surface.
Figure 6 Hoisting diagram
5. Installation of the pipeline
5.1 Attention
● Prevent air, dust and other sundries from going into the water pipes.
● Fix the whole system before install the water pipes.
● Water inlet and outlet pipes shall be protected by the insulation layer.
● Stable water velocity shall be ensured, so that excessive throttling can be avoid.
● When moving, water inlet and outlet pipe shall not be used for hanging, only the holes on the beam of
the base can be used, please refer to Figure 9
● When connect the water inlet and outlet pipes, two pipe wrenches shall be used to control the two parts
of the pipes, and ensure the water inlet and outlet pipes not turning around, please refer to the Figure 7
● Pipeline anti-freezing in case the environmental temperature drops to 3°C.
Figure 7
Table of contents
Other Sunrain Heat Pump manuals
Popular Heat Pump manuals by other brands

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Service manual

Dimplex
Dimplex LI 16I-TUR Installation and operating instruction

Carrier
Carrier WSHP Open v3 Integration guide

TGM
TGM CTV14CN018A Technical manual

Carrier
Carrier 38MGQ Series installation instructions

Kokido
Kokido K2O K880BX/EU Owner's manual & installation guide

Viessmann
Viessmann VITOCAL 300-G PRO Type BW 2150 Installation and service instructions

Carrier
Carrier 48EZN installation instructions

Viessmann
Viessmann KWT Vitocal 350-G Pro Series Installation and service instructions for contractors

Ariston
Ariston NIMBUS user manual

Weishaupt
Weishaupt WWP L 7 Installation and operating instruction

GE
GE Zoneline AZ85H09EAC datasheet