Installation procedure
Hands free reader: L51 - R13 Variant / RS485 type 7S
© STId 2005– NI016C01 P. 6 / 9
Reader configuration (SETUP mode)
To configure the reader (address, communication characteristics), you need to go into SETUP mode.
-Switch off the reader
-Fit the SETUP jumper
-Switch on the reader (the reader will automatically send a message on the bus)
You are now into SETUP mode, you can configure the reader to your needs. When you have finish to
configure the reader :
-Switch off the reader
-Remove the SETUP jumper
-Switch on the reader
To get more information about how the RS485 7S reader is operating, please check the 7S protocol
specification
Optimization
If you do not have the best performances, some simple tips could help you to get them.
•Analyze the environment to find possible causes of perturbation
•Verify the wiring. Check that all contacts are corrects.
•Verify that the 0V is connected to a clean ground
•Measure the power supply. In some cases, the power supply doesn’t succeed to drive enough
current and its voltage drop. If you have less than 12V, the performance can be reduced a lot
•Measure the consumption. If you don’t have around 500 mA, you need to calibrate the reader to its
environment (see the calibration section).
•Try to move the reader and/or change its orientation.
TIPS: You can use a 12V battery to power the reader and it will be easier to move it.
CAUTION: All detection tests need to be done with the embedded ‘CP’ LED.
If you move the reader and get better performance on a new place, it means the initial place was not
compliant for long range 125 kHz readers.