Step Technica MKY02 User manual

HUB-IC MKY02
User’s Manual
(for Hi-speed Link System)
STD-HLS02-V1.7E

Note
1. The information in this document is subject to change without prior notice. Before using this
product, please confirm that this is the latest version of this document.
2. Technical information in this document, such as explanations and circuit examples, are refer-
ences for this product. When actually using this product, always fully evaluate the entire sys-
tem according to the design purpose based on considerations of peripheral circuits and the
PC board environment. We assume no responsibility for any incompatibility between this
product and your system.
3. We assume no responsibility whatsoever for any losses or damages arising from the use of
the information, products, and circuits in this document, or for infringement of patents and any
other rights of a third party.
4. When using this product and the information and circuits in this document, we do not guaran-
tee the right to use any property rights, intellectual property rights, and any other rights of a
third party.
5. This product is not designed for use in critical applications, such as life support systems. Con-
tact us when considering such applications.
6. No part of this document may be copied or reproduced in any form or by any means without
prior written permission from StepTechnica Co., Ltd..
Trademark “HLS” is licensed by Murata Manufacturing Co., Ltd.

MKY02 User’s Manual
- iii -
Preface
This manual describes the MKY02, or a kind of HUB-IC in a Hi-speed Link System.
Be sure to read “Hi-speed Link System Introduction Guide” before understanding this manual
and the MKY02.
In this manual, the Hi-speed Link System is abbreviated as “HLS”.
zTarget Readers
This manual is for:
yThose who first build an HLS
yThose who first use StepTechnica's various ICs to build an HLS
zPrerequisites
This manual assumes that you are familiar with:
yNetwork technology
ySemiconductor products (especially microcontrollers and memory)
zRelated Manuals
yHi-speed Link System Introduction Guide
yHi-speed Link System Technical Guide
yHi-speed Link System Center IC Manuals
[Caution]
ySome terms in this manual are different from those used on our website and in our product bro-
chures. The brochure uses ordinary terms to help many people in various industries understand
our products.
Please understand technical information on HLS Family and CUnet Family based on technical
documents (manuals).

MKY02 User’s Manual
(for Hi-speed Link System)
- iv -
CONTENTS
Chapter 1 Concepts for Using MKY02 (HUB)
1.1 Role of MKY02 ....................................................................................................... 1-3
1.2 Basic HLS Configuration ...................................................................................... 1-3
1.3 HLS Configuration using HUBs ........................................................................... 1-4
1.3.1 Extending Total Length of Network Cable ................................................................ 1-4
1.3.2 Branching Multi-dropped Network Cables................................................................ 1-6
1.3.3 Eliminating Connection or Disconnection of Termination Resistor
to or from Each Device ............................................................................................... 1-7
1.3.4 Star Topology ..............................................................................................................1-8
1.4 Basic HUB Connection ......................................................................................... 1-9
1.5 Multi-drop Network of HUBs .............................................................................. 1-10
1.6 Port Addition to HUB .......................................................................................... 1-11
1.7 MKY02 Operation ................................................................................................ 1-12
1.7.1 Receiving and Sending Packets .............................................................................. 1-12
1.7.2 Signal Correction....................................................................................................... 1-13
1.7.3 Detection of Error Packet ......................................................................................... 1-13
1.8 Features of MKY02 .............................................................................................. 1-14
Chapter 2 MKY02 Hardware ................................................................................2-3
Chapter 3 Single Connection of MKY02
3.1 Voltage Levels of Pins Connecting to Signal Pins............................................. 3-4
3.2 Supplying Driving Clock and Hardware Reset Signal ....................................... 3-5
3.2.1 Supplying Driving Clock ............................................................................................. 3-5
3.2.2 Setting Cascade Clock and Baud Rate...................................................................... 3-6
3.2.3 Hardware Reset ........................................................................................................... 3-7
3.3 Connecting Network Interface ............................................................................. 3-8
3.3.1 Selecting Communication Mode ................................................................................ 3-8
3.3.2 Connection of Port 0 ................................................................................................... 3-8
3.3.3 Connection of Ports 1 to 7.......................................................................................... 3-9
3.3.4 Recommended Network Connection....................................................................... 3-10
3.4 Connecting Monitor LEDs .................................................................................. 3-11
3.4.1 Packet Receive Monitor ............................................................................................ 3-11
3.4.2 Packet Error Monitor ................................................................................................. 3-12
3.4.3 Port Receive Monitor................................................................................................. 3-13
3.5 Handling Cascade Connection Pins.................................................................. 3-15
3.6 Cautions for Designing HUB .............................................................................. 3-15
3.7 Example Circuit for Single Connection of MKY02 ........................................... 3-16

MKY02 User’s Manual
- v -
Chapter 4 Cascade Connection of MKY02
4.1 Concepts of Port Addition.................................................................................... 4-3
4.1.1 Port Addition by Stacking Method............................................................................. 4-3
4.1.2 Port Addition by Cascade Connection ...................................................................... 4-4
4.1.3 Maximum Available Cascade Connections............................................................... 4-4
4.2 Practical Side of Cascade Connection................................................................ 4-5
4.2.1 Cascade Pins ...............................................................................................................4-5
4.2.2 Operation of Cascade Connection Pins .................................................................... 4-6
4.2.3 Connection of Cascade Clocks and Determination of Baud Rate .......................... 4-7
4.2.4 Connection of Hardware Reset Signal ...................................................................... 4-7
4.2.5 Selecting Communication Mode ................................................................................ 4-8
4.2.6 Connection of Each Port............................................................................................. 4-8
4.2.7 Placement of Monitor LEDs........................................................................................ 4-9
4.3 Example Circuit for Port-added HUB by Cascade Connection....................... 4-10
Chapter 5 Ratings
5.1 Electrical Ratings .................................................................................................. 5-3
5.2 AC Characteristics ................................................................................................ 5-3
5.2.1 Clock and Reset Timing.............................................................................................. 5-4
5.2.2 Port Pin Timing (TXE0 to 7, TXD0, TXD17, RXD0 to 7)............................................. 5-5
5.2.3 Cascade Connection Pin Timing................................................................................ 5-6
5.2.4 Output Timing of #LEDRCV and #LEDRZE Pins ...................................................... 5-6
5.2.5 Timing of Receive Monitor Pin of Individual Port (RLLD, RLDT, RLCK) ................ 5-7
5.3 Package Dimensions ............................................................................................ 5-8
5.4 Recommended Soldering Conditions ................................................................. 5-9
5.5 Recommended Reflow Conditions ...................................................................... 5-9

MKY02 User’s Manual
(for Hi-speed Link System)
- vi -
Figures
Fig. 1.1 Basic HLS Configuration.............................................................................. 1-3
Fig. 1.2 Extension of Network Cable Length ........................................................... 1-4
Fig. 1.3 Multipoint Connection of Network Cables.................................................. 1-6
Fig. 1.4 Eliminating Problems with Termination Resistors .................................... 1-7
Fig. 1.5 Star Topology................................................................................................ 1-8
Fig. 1.6 Basic Connection and Number of Inserted HUBs ..................................... 1-9
Fig. 1.7 HUB in Intermediate Position of Multi-drop Network .............................. 1-10
Fig. 1.8 Adding Ports by Cascading MKY02s ........................................................ 1-11
Fig. 1.9 Inserted Count of HUBs with Added Ports............................................... 1-11
Fig. 1.10 MKY02 Operating Principles...................................................................... 1-12
Fig. 1.11 Example of Signal Transformation and Correction ................................. 1-13
Fig. 2.1 MKY02 Pin Assignment................................................................................ 2-3
Fig. 2.2 Pin Electrical Characteristics in I/O Circuit Types of MKY02 ................... 2-6
Fig. 3.1 Connection Causing Leakage Current........................................................ 3-4
Fig. 3.2 Cascade Clock Generation .......................................................................... 3-6
Fig. 3.3 Clock Connection ......................................................................................... 3-6
Fig. 3.4 Hardware Reset............................................................................................. 3-7
Fig. 3.5 Selecting Communication Mode ................................................................. 3-8
Fig. 3.6 TRX Connection of Port 0 ............................................................................ 3-8
Fig. 3.7 TRX Connection of Ports 1 to 7 ................................................................... 3-9
Fig. 3.8 TRX Connection of HUB with 4 Ports ......................................................... 3-9
Fig. 3.9 Recommended Network Connection ........................................................ 3-10
Fig. 3.10 Connection of Receive Monitor LED......................................................... 3-11
Fig. 3.11 Connection of Packet Error Monitor LED ................................................. 3-12
Fig. 3.12 RLLD, RLDT, and RLCK Outputs............................................................... 3-13
Fig. 3.13 8-port Receive Monitor ............................................................................... 3-14
Fig. 3.14 4-port Receive Monitor ............................................................................... 3-14
Fig. 3.15 Handling of Cascade Connection Pins ..................................................... 3-15
Fig. 3.16 Example of Single Connection Circuit in Half-duplex Mode................... 3-16
Fig. 3.17 Example of Single Connection Circuit in Full-duplex Mode ................... 3-17

MKY02 User’s Manual
- vii -
Fig. 4.1 Addition of Three-stacked Ports ................................................................. 4-3
Fig. 4.2 Port Addition by Three Cascade Connections........................................... 4-4
Fig. 4.3 Cascade Pin Connection for Three MKY02s .............................................. 4-5
Fig. 4.4 Cascade Pin Connection for Two MKY02s................................................. 4-5
Fig. 4.5 Center Ports and Operation during Receiving........................................... 4-6
Fig. 4.6 Satellite Ports and Operation during Receiving ........................................ 4-6
Fig. 4.7 Connection of Cascade Clocks ................................................................... 4-7
Fig. 4.8 Selection of Communication Mode ............................................................. 4-8
Fig. 4.9 Monitor Placement Example for Port-added HUB ..................................... 4-9
Fig. 4.10 Example Circuit for HUB with 22 Ports..................................................... 4-10
Fig. 4.11 Example of Connection in Full-duplex Mode ........................................... 4-13
Tables
Table 1-1 Baud Rates and Recommended Total Extension Number
of Inserted HUBs.......................................................................................... 1-4
Table 2-1 Pin Functions of MKY02.............................................................................. 2-4
Table 2-2 Electrical Ratings of MKY02........................................................................ 2-6
Table 3-1 Output Frequencies of Cascade Clocks .................................................... 3-6
Table 5-1 Absolute Maximum Ratings ........................................................................ 5-3
Table 5-2 Electrical Ratings......................................................................................... 5-3
Table 5-3 AC Characteristics Measurement Conditions ........................................... 5-3

MKY02 User’s Manual
(for Hi-speed Link System)
- viii -

Chapter 1 Concepts for Using MKY02 (HUB)
This chapter describes the concepts for using the MKY02 (HUB) in the Hi-speed Link
System (HLS).
1.1 Role of MKY02................................................................................1-3
1.2 Basic HLS Configuration ..............................................................1-3
1.3 HLS Configuration using HUBs....................................................1-4
1.4 Basic HUB Connection..................................................................1-9
1.5 Multi-drop Network of HUBs.......................................................1-10
1.6 Port Addition to HUB...................................................................1-11
1.7 MKY02 Operation.........................................................................1-12
1.8 Features of MKY02 ......................................................................1-14

Other manuals for MKY02
1
Table of contents
Other Step Technica Computer Hardware manuals
Popular Computer Hardware manuals by other brands

EMC2
EMC2 VNX Series Hardware Information Guide

Panasonic
Panasonic DV0PM20105 Operation manual

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 user manual

Gigabyte
Gigabyte B660M DS3H AX DDR4 user manual

Raidon
Raidon iT2300 Quick installation guide

National Instruments
National Instruments PXI-8186 user manual