Steca coolcept StecaGrid 1500 User guide

Installation and operating instructions
EN
coolcept coolcept-x
747.431 | Z09.2 | 2016-02-18

Table of contents
1 Preface................................................................................. 4
2 General information........................................................... 5
2.1 General safety instructions........................................... 5
2.2 Identification................................................................ 6
2.3 Scope of delivery.......................................................... 8
2.4 Intended use................................................................ 8
2.5 About this manual....................................................... 9
3 Structure and function..................................................... 12
3.1 Housing...................................................................... 12
3.2 Operating buttons..................................................... 14
3.3 Display....................................................................... 14
3.4 Cooling...................................................................... 21
3.5 Grid monitoring......................................................... 22
3.6 Data communication.................................................. 22
4 Installation........................................................................ 31
4.1 Safety measures during installation........................... 31
4.2 Mounting the inverter................................................ 33
4.3 Prepare AC connection............................................... 35
4.4 Prepare DC connections............................................. 37
4.5 Preparing the data connection cable.......................... 38
4.6 Connecting the inverter inverter and switching the
AC on......................................................................... 38
4.7 Initial commissioning of the inverter.......................... 39
4.8 Feed-in management................................................. 46
4.9 Switch on DC............................................................. 47
4.10 Deinstalling the inverter........................................... 47
5 Operation.......................................................................... 49
5.1 Overview of operating functions................................ 49
5.2 General operating functions...................................... 50
5.3 Important operating functions................................... 50
5.4 Internet portal............................................................ 53
6 Self test.............................................................................. 60
7Fault rectification.............................................................. 63
8 Maintenance and disposal............................................... 69
8.1 Maintenance.............................................................. 69
8.2 Disposal..................................................................... 69
9 Technical data................................................................... 70
9.1 Inverter...................................................................... 70
9.2 AC cables and line circuit breakers............................. 81
9.3 Country table............................................................. 82
EN
747,431 | Z09.2 | 18/02/2016
2

10 Liability, commercial guarantee, legal guarantee.......... 83
11 Contact.............................................................................. 84
Appendix........................................................................... 85
A Assembly...................................................................... 86
A.A Bore dimension drawing for coolcept devices........... 86
A.B Bore dimension drawing for coolcept-x devices......... 87
A.C AC plug...................................................................... 88
A.D Phoenix Contact SUNCLIX (DC connector)................. 91
EN
747,431 | Z09.2 | 18/02/2016
3

1 Preface
Thank you for choosing inverters from the coolceptproduct line of
Steca Elektronik GmbH . By using solar energy, you are making a
significant contribution to environmental protection; by reducing the
amount of carbon dioxide (CO2) and other harmful gases that
burden the earth's atmosphere.
Maximum efficiency with a long service life
The innovative inverter topology is based on a single-stage
transformer-less circuit concept and is integrated into all devices in
the coolcept series. This unique technology allows peak efficiencies
of 98,0 % or 98,6 % to be achieved. Depending on the type, the
European efficiency of the devices is also significantly greater than
98 % and sets new standards in photovoltaic grid-feed systems.
A new and unique cooling concept inside the inverter ensures an
even distribution of heat and a long service life.
Designer casing and easy installation
For the first time, the very high efficiency allows the use of a
designer casing made of plastic for the coolcept inverters. This offers
many advantages. The surface temperatures of the devices overall
remains extremely low. In addition, there are clear benefits for the
installation. The coolcept-x inverters have a sturdy metal casing that
allows them to be also used outdoors.
The lightweight devices weigh only 9 or 12 kg and can be easily and
safely mounted on a wall. The supplied wall bracket and practical
recessed grips for right and left handed installers make mounting of
the device simple and convenient. All connections and the DC circuit
breaker are externally accessible.
Visualization and accessories
The devices have a graphic display, with which the energy load
values, actual capacities, and operating parameters of the
photovoltaic system can be visualized. The innovative menu offers
the possibility of individual selection of the different measured
values.
See www.stecasolar.com for further information on accessories.
Your installer can, of course, also give you more information about
the options and accessories that are available.
EN
747,431 | Z09.2 | 18/02/2016
4

2 General information
2.1 General safety instructions
nThis document is part of the product.
nInstall and use the device only after reading and understanding
this document.
nAlways perform the measures described in this document in the
sequence specified.
nKeep this document in a safe place for the entire service life of
the device. Pass the document on to subsequent owners and
operators of the device.
nThe yield of the system can be reduced through improper
operation
nIf the housing is damaged, do not connect the device to the DC
or AC lines
nIf one of the following components is damaged, immediately
take the device out of operation and disconnect it from the
mains grid and PV generators.:
– Device (not functioning, visible damage, smoke,
penetration of liquid etc.)
– Lines
– PV generators
Do not switch the system on again before
– the device has been repaired by a dealer or the
manufacturer,
– Damaged cables or PV generators have been repaired by a
technical specialist.
nNever cover the device
nDo not open the casing: Risk of death. Invalidation of the
guarantee.
nFactory labels and markings must never be altered, removed or
rendered unreadable.
nComply with the instructions of the respective manufacturer
when you connect an external component that is not described
in this document (e.g. external data loggers). Components that
are incorrectly connected can damage the device.
EN
747,431 | Z09.2 | 18/02/2016
5

①Dangerous voltages can remain present on the components up
to 10minutes after switching off the DC circuit breaker and the
line circuit breaker.
②Read and follow the manual!
③Serial number as a bar code and in plain text
①Caution: Surface may be hot
②Dangerous voltages can remain present on the components up
to 10minutes after switching off the DC circuit breaker and the
line circuit breaker.
③Read and follow the manual!
④Serial number as a bar code and in plain text
2.2 Identification
Feature Description
Types coolcept (plastic housing): StecaGrid 1500, StecaGrid 2000,
StecaGrid 2500, StecaGrid 3010, StecaGrid 3600, StecaGrid 4200
coolcept-x (stainless steel housing): StecaGrid 1500x,
StecaGrid 2000x, StecaGrid 2500x, StecaGrid 3010x,
StecaGrid 3600x, StecaGrid 4200x
Version status of the
manual
Z09
Manufacturer's address See
Ä
Chapter 11 ‘Contact’ on page 84
Safety information on
the device (coolcept
Indoor)
Safety information on
the device (coolcept
Indoor)
EN
747,431 | Z09.2 | 18/02/2016
6

Feature Description
Certificates See Appendix ⇒ Certificates and
www.stecasolar.com ⇒ coolcept – coolcept-x
Optional accessories nExternal data loggers:
–WEB‘log from Meteocontrol
–Solar-Log from Solare Datensysteme
nTermination plug for RS485 bus
–IP21: 752,856
– IP65: 740,864
①Bar code for internal use
②Protection class
③Technical data of the DC input
④Article number and product designation
⑤Manufacturer's address
⑥Cover the Protection class II and CE mark
⑦Country of manufacture
⑧Technical data of the AC output
⑨Standard for grid monitoring
Notice
–For Australia only: Cover the
Protection class IIsymbol on the type plate, as
described on
Ä
‘ For Australia only: Cover the
Protection class II symbol on the type plate. ’
on page 33.
–For the serial number, see
Ä
‘Safety information
on the device (coolcept Indoor)’ on page 6 and
Ä
‘Safety information on the device (coolcept
Indoor)’ on page 6
–For the position of the type plate, see
Ä
Chapter
3.1 ‘Housing’ on page 12.
The products described in this document comply with the applicable
European directives. Certificates for the products are provided at
www.stecasolar.com ⇒ PV GRID CONNECTED ⇒ Grid inverters
Rating plate
1
7
2
3
4
5
6
8
⑨
EU Declaration of
Conformity
EN
747,431 | Z09.2 | 18/02/2016
7

2.3 Scope of delivery
nInverter ①, type coolcept (plastic housing) or coolcept-x
(stainless steel housing, IP65)
nMounting plate ② for type coolcept or coolcept-x
nAC plug ③
n1 pair SUNCLIX plug-in connectors ④
n3 sealing caps (for RJ45 socket; only coolcept-x) ⑤
nBrief installation and operating instructions ⑥
①
②
③④⑤
⑥
2.4 Intended use
nThe inverter must only be used in grid-coupled photovoltaic
systems. The inverter is suitable for all PV generator with
connections that do not need to be grounded.
nPV generator must be used that have an IEC 61730 class A
rating because the inverter does not have electrical isolation.
nIf the maximum AC operating voltage is higher than the
maximum system voltage of the photovoltaic generator, then
PV generator must be used that have a maximum system
voltage that is higher than the AC grid voltage.
Notice
An overview of suitable PV generators is available at
www.stecasolar.com
Þ
PV GRID CONNECTED
Þ
Service and support.
EN
747,431 | Z09.2 | 18/02/2016
8

UPV = Potential between the plus (+) and minus (–) DC‑connections
StecaGrid 1500/2000 and 1500x/2000x
375 V
−350 V
DC (+)
DC (−)
U
t
0 V
UPV= 350 V
375 V
−75 V
DC (+)
DC (−)
U
t
0 V
UPV= 75 V
Fig. 1: Potential curves of UPV at 75 V (left) and 350 V (right)
StecaGrid 2500/3010 and 2500x/3010x
125 V
−160 V
DC (+)
DC (−)
U
t
0 V
−320 V
UPV = 125 V
180 V
−180 V
−250 V
250 V
320 V
0 V
−320 V
U
t
UPV = 500 V
DC (+)
DC (−)
Fig. 2: Potential curves of UPV at 125 V (left) and 500 V (right)
StecaGrid 3600/4200 and 3600x/4200x
175 V
−175 V
−275 V
275 V
320 V
U
t
0 V
−320 V
UPV = 350 V
DC (+)
DC (−)
175 V
−175 V
−275 V
275 V
320 V
0 V
−320 V
U
t
UPV = 550 V
DC (+)
DC (−)
Fig. 3: Potential curves of UPV at 350 V (left) and 550 V (right)
2.5 About this manual
2.5.1 Contents
This manual describes the inverters of the types coolcept and
coolcept-x. The points at which the types differ are marked in the
text.
Potential curves of the
plus (+) and minus (–) DC
connections with respect
to PE
EN
747,431 | Z09.2 | 18/02/2016
9

This manual contains all information that a specialist needs to set up
and operate the inverters. Follow the instructions of the respective
manufacturers when installing other components (e.g. PV generator,
cables).
2.5.2 Target group
Unless otherwise indicated, the target audiences of this manual are
technical professionals and system operators. Technical professionals
are, for example:
nPersons who have the knowledge of terminology and the skills
necessary for setting up and operating photovoltaic systems.
nPersons who have the necessary training, knowledge and
experience, and knowledge of the applicable regulations in
order to evaluate and recognise the dangers inherent in the
following work:
–Installation of electrical equipment
– Production and connection of data communication cables
– Production and connection of mains grid power supply
cables
2.5.3 Designations
The following table contains the symbols used in this manual
Warning signs Type of danger
Warning – high-voltage.
Warning – danger zone.
The following table contains the symbols used on the device.
Cover the Description
Danger from electricity.
Read the manual before using the product.
Symbols
Symbols used on the
device
EN
747,431 | Z09.2 | 18/02/2016
10
Other manuals for coolcept StecaGrid 1500
1
This manual suits for next models
11
Table of contents
Other Steca Inverter manuals

Steca
Steca Solarix 2020-x2 User manual

Steca
Steca XPC 1400-12 Use and care manual

Steca
Steca coolcept fleX Series Manual

Steca
Steca Fronius Solarix 400 I User manual

Steca
Steca Solarix PI 500-12 User manual

Steca
Steca StecaGrid 8 000+ 3ph User manual

Steca
Steca StecaGrid 1900 Series User manual

Steca
Steca coolcept StecaGrid 3000 User manual

Steca
Steca AJ 275 Use and care manual

Steca
Steca stecagrid 300 User manual