stayer GID1000 User manual

GID1000
GID1400
GID2200
GAV2800
GAV5500E
GAV7500E
www.grupostayer.com
Manual de instrucciones
ES
Área Empresarial Andalucía - Sector I
Calle Sierra de Cazorla nº7
C.P: 28320 Pinto (Madrid) SPAIN
Email: sales@grupostayer.com
Email: info@grupostayer.com
Istruzioni d’uso
IT
Operating instructions
GB
Instructions d’emploi
FR
Manual de instruções
P


GID1000
Fig. 2 1
5
10
3
8
2
4
12
15
16
6

Fig. 3
3 7
6
5
1
17
Fig. 2
1
17
7
6
5
GID1400
GID2200
37
17
19
910 11
12
14
13
8
15
20
910
12
11
13
1520
14
8



6.1.
L dB(A)
PA
70
62
64
74
79
L dB(A)
WA
92
95
96
98
98
98
2
a m/s
h
2
2
2
2
2
GID 1000
GID 1400
GID 2200
GAV 2800
GAV 5500 E
GAV 7500 E
KW
0.9
0.9
2.0
2.8
5.5
6.5
A
3.7
4
8.7
11
22
26
Vcc
12
12
12
12
12
12
H
2.5
6
6.5
13
9
8
kg
12
14.7
28
50
82
88
V
K=3 dB
2
K=1.5 m/s
kg
KW
L
2
2.7
7
15
25
25
Kw
1.25
1.4
3.4
3.8
7.5
7.5
3
cm
63
53
125
196
389
439
L
-
0.25
0.45
0.6
1.1
1.1
KW
cc
Motor

Always wait until the machine has come to a complete
stop before placing it down. The tool insert can jam and
lead to loss of control over the power tool.
Wipe up spilled gasoline at once.
Connections for standby power to a building's
electrical system must be made by a qualified
electrician and must comply with all applicable laws
and electrical codes. Improper connections can allow
electrical current from the generator to back feed into the
utility lines. Such back feed may electrocute utility company
workers or others who contact the lines during a power
outage, and when utility power is restored, the generator
may explode, burn, or cause fires in the building's electrical
system.
Always make a pre-operation inspection before you
start the engine. You may prevent an accident or
equipment damage.
Place the generator at least 1m (3ft) away from
buildings or other equipment during operation.
Operate the generator on a level surface. If the generator
is tiled, fuel spillage may result.
Know how to stop the generator quickly and
understand operation of all the controls. Never permit
anyone to operate the generator without proper
instructions.
Keep children and pets away from the generator when
it is in operation.
Keep away from rotating parts while the generator is
running.
The generator is a potential source of electrical shocks
when misused; do not operate with wet hands.
Do not operate the generator in rain or snow and do not
let it get wet.
To prevent electrical shock from faulty appliances, the
generator should be grounded. Connect an electric
conductor (cable) of at least 1.5mm² between the
generator's ground terminal and an external ground
source.
Limit operation requiring maximum power to 30
minutes. For continuous operation, do not exceed the
rated power. In either case, the total wattage of all
appliances connected must be considered.
Do not exceed the current limit specified for any one
receptacle.
Do not modify or use the generator for other purpose
than it is intended for. Also observe the following when
using the generator:
- Do not connect generators in parallel.
- Do not connect an extension to exhaust pipe.
- When an extension cable is required, be sure to use a
rubber sheathed flexible cable.
1. Contents
page
2.Specific safety instructions......................................22
3.Instructions for use....................................................23
3.1 Placement Tool.............................................................23
3.2 Electrical connection.....................................................23
3.3 Generator start.....................................................23
3.4 Output Indicators and overload.............................23
3.5 Battery charging...................................................23
3.6 Illustrated description............................................24
3.7 Limitations of environmental conditions................24
4.Operating instructions..............................................24
4.1 Placement and testing..........................................24
4.2 Start 4T.................................................................24
4.3 System Low oil warning.........................................24
4.4 AUX output 12V.....................................................24
4.5 Overload...............................................................24
4.6 Stopping the engine.............................................24
4.7 Electrical installation...........................................24
4.8 Location and Troubleshooting...............................25
5.Maintenance and service instructions.....................25
5.1 Maintenance Schedule.........................................25
5.2 Lubricating oil.......................................................26
5.3 Oil change............................................................26
5.4 Fuel......................................................................26
5.5 Air filter..................................................................26
5.6 Air Filter Maintenance...........................................26
5.7 Maintenance of the spark plug...............................27
5.8 Transport and storage..........................................27
5.9 Equipment storage...............................................27
5.10 Repair service...................................................27
5.11 Warranty...........................................................27
5.12 Disposal and recycling......................................27
6.Regulations................................................................28
6.1 Technical Data......................................................28
6.2 EU declaration of conformity.................................28
2. Specific safety instructions
The generator is designed to give safe and dependable
service if operated according to instructions.
Read and understand the Owner's Manual before
operating the generator. Failure to do so could result in
personal injury or equipment damage.
Exhaust gas contains poisonous carbon monoxide. Never
run the generator in an enclosed area. Be sure to provide
adequate ventilation.
The muffler becomes very hot during operation and
remains hot for a while after stopping the engine. Be careful
not to touch the muffler while it is hot. Let the engine cool before
storing the generator indoors. To prevent scalding, pay attention
to the warning marks.
Gasoline is extremely flammable and explosive under
certain conditions. Refuel in a well ventilated area with the
engine stopped.
Keep away from cigarette, smoke and sparks when re-
fuelling the generator. Always refuel in a well ventilated
location.
ENGLISH
8
8

If the generator is overloaded or if there is a short in the
connected appliance, the output indicator light (green) will
go OFF, the overload indicator light (red) will go ON and
current to the connected appliance will be shut off.
Stop the engine if the overload indicator light (red) switches
ON and investigate the overload source.
Before connecting an appliance to the generator,
check that it is in good order, and that its
electrical rating does not exceed that of the
generator. Then connect the power cord of the
appliance, and start the engine.
Connect the ground terminal according to the regulations in
force.
3.5 Battery charging
When using the DC output 15, turn Smart Throttle to the
OFF position. The DC current will be below 5A if turning on
the Smart Throttle without AC current output.
When charging batteries, person must be present
to monitor the voltage.
Stop charging when the voltage of the batteries is above
14.4V. Or it may cause battery explosion, resulting in
serious injury or death.
To prevent the possibility of creating a spark near the
battery, connect charging cable first to the generator, then
to the battery. Disconnect cable first at the battery.
Before connecting charging cables to a battery that is
installed in a vehicle, disconnect the vehicles grounded
battery cable. Reconnect the vehicle's grounded battery
cable after the charging cables are removed. This
procedure will prevent the possibility of a short circuit and
sparks if you make accidental contact between a battery
terminal and the vehicle's frame or body.
Do not attempt to start an automobile engine while the
generator still connected to the battery. The generator may
be damaged.
Connect the positive battery terminal to the positive
charging cord. Do not re-verse the charging cables, or
serious damage to the generator and/or the battery may
occur.
The battery gives off explosive gases; keep spark, flames
and cigarettes away. Provide adequate ventilation when
charging.
The battery contains sulphuric acid (electrolyte). Contact
with skin or eyes may cause severe burns. Wear protective
clothing and a face shield.
If electrolyte gets on your skin, flush with water.
If electrolyte gets in your eyes, flush with water for at least
15 minutes and call a physician. Electrolyte is poisonous.
If swallowed, drink large quantities of water or milk and
follow with milk or magnesia or vegetable oil and call a
physician.
- Limit length of extension cables: 60m for cables of
2 2
1.5mm and 100m for cables of 2.5mm .
- Keep the generator away from other electric cables
or wires such as distribution network.
- The DC receptacle can be used while the AC power
is in use. If you use both at the same time, be sure
not to exceed the total power for AC and DC.
- Most appliance motors require more than their rated
wattage for start-up.
AC applications
Start the engine and make sure the output indicator light 10
(green) illuminates or dial 230 voltmeter (
).
Confirm that the appliance to be used is switched off, and
plug in the appliance.
Substantial overloading that continuously lights the
overload indicator light (red) 9 may damage the generator.
Marginal overloading that temporarily lights the overload
indicator light (red) may shorten the service life of the
generator.
Be sure that all appliances are in good working order before
connecting them to the generator. If an appliance begins to
operate abnormally, becomes sluggish, or stops suddenly,
turn off the generator engine switch immediately. Then
disconnect the appliance, and examine it for signs of
malfunction.
3.Instructions for use
3.1 Placement Tool
For your own safety, read this manual and the
general safety instructions carefully before
using the appliance. Your power tool should only
be given to other users together with these
instructions.
Be sure to check the generator on a level surface
with the engine stopped.
3.2 Electrical connection
GID1000,
GAV2800, GAV5500E, GAV7500E
3.3 Generator start
Start engine according to “Operating instructions”.
Confirm that the equipment to be used is switched off, and
insert the plug of the equipment to be used into the AC
receptacle unit A.
Check that the equipment to be connected is switch off.
When the equipment to be used is switched on, it will
operate suddenly, and injuries or accidents may be
caused.
3.4 Output Indicators and overload
The output indicator light 10 will remain lighted during
normal operating conditions.
When the output indicator light (green) does not
light and the overload indicator light (red) lights.
ENGLISH
9
9

Keep out of the reach of children, pets and
untrained people.
1Fuel cap
2Fuel level indicator
3Remote starter
4Control panel
5Starting grip
6Command the fuel shutoff valve
7Maintenance cover
8AC socket
9Overload indicator light
10 Output indicator available
11 Oil alert indicator light
3.6 Illustrated description
12 ON/OFF Switch
13 Switch economizer
14 Electrical Grounding
15 Out of 12 Vdc
16 Automatic output Protector
17 Oil drain plug
18 Oil filler cap
19 Fuel primer bulb
20 Overload Protector 12V
3.7 Limitations of environmental conditions
Apply regard contained in Chapter 2 "specific safety
instructions."
4. Operating instructions
4.1 Placement and testing
Be sure to check the generator on a level surface
with the engine stopped.
4.2 Start 4T (except GID 1000)
Before starting the engine, disconnect any load
from the receptacle.
Set the fuel valve in the “ON”-position.
To start a cold motor shove the choke lever all the way to the
left. To restart a hot motor set the choke lever half-way.
Shove the choke to about halfway to restart a warm motor.
A hot motor will not start if there is too much fuel
in the cylinder.
If this happens, wait five to ten minutes before
trying again. Shove the choke completely to the
right and the motor should start.
Set the motor switch 12 in the “ON”-position.
Pull slightly on the start cord 5 until you feel resistance and
then yank hard and swiftly.
Do not let the start cord retract by itself: guide it
back by hand. Hold the carrying handle firmly to
prevent the generator from falling over when you
pull the start cord.
Press the choke in completely after the engine is started.
ENGLISH
10
10
Economizer button will fuel saving mode 12V max supply.
Never start with the economizer.
If the engine stops and will not restart, check the
engine oil level before troubleshooting in other
areas.
Start GID1000 (2T)
GID1000 model has a 2-stroke engine.
GAV2800 and GAV5500E models have a 4-stroke engine.
Turn the fuel valve ON.
To boot, full choke left the starter 3. Pull the lever 5 until you
hear the first detonations.
Then put the starter 3 in medium or low position and pull the
starter definitive.
4.3 System Low oil warning
Models GID1400 / GID2200: The oil alert system 11 is
designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil
level in the crankcase falls below a safe limit, the oil alert
system will automatically shut down the engine (the engine
switch will remain in the ON position).
If the oil alert system shuts down the engine, the oil alert
indicator light (red) will come on when you operate the
starter, and the engine will not run. If this occurs, add engine
oil. The other models have no explicit warning of low oil.
However not start if the oil level is low.
4.4 AUX output 12V
The 12 Vdc auxiliary connection can be used while using
the AC output.
A GID1000 DC overload, and GID 2200 GID1400
disconnect the DC circuit protector 20. If this happens,
unplug the DC load before resetting the circuit protector to
resume operation.
4.5 Overload
The team cut the electricity supply if a consumer exceeds
the maximum, to restore supply shut off the engine and
start it again in the models GID (Inverter). In AVR
moldelos reset the circuit breaker 16.
4.6 Stopping the engine
To stop the engine in an emergency, turn the engine switch
12 to the OFF position.
In normal use:
Switch off the connected equipment and pull the inserted
plug out.
Turn the engine switch 12 to the OFF position.
Turn the cap lever fully counter clockwise to the "OFF"
position.
Be sure both the fuel cap lever and the engine
switch are in "OFF" position when stopping,
transporting and/or storing the generator.
This manual suits for next models
5
Table of contents
Other stayer Portable Generator manuals