SMARTFOX Pro 2 User manual

www.smartfox.at
SMARTFOX Pro 2
Operating instructions
Manual Version 12 - 04.2022
SMARTFOX
Version - EM2 00.01.03.17 | V.3.17
www.smartfox.at

DECLARATION SAFETY
INSTRUCTIONS
www.smartfox.at
WARNING
Non-compliance can lead to damage to property and personal injury. The
instructions given must therefore always be observed or implemented!
ATTENTION
Non-compliance can lead to malfunctions or damage to the unit. The instructions
given must therefore always be followed or implemented!
NOTE
Useful tips to support you during commissioning. The instructions given are not
mandatory.
2

TABLE OF CONTENTS
www.smartfox.at
General Information .....................................................................................................4
General Notes. ....................................................................................................4
Conformity. .....................................................................................................................4
Application. .....................................................................................................................4
Function...........................................................................................................................4
Scope of delivery and technical data. ........................................................................5
Regulations.....................................................................................................................6
Dimensions.....................................................................................................................6
Assembly ........................................................................................................................6
Electrical connection............................................................................................6
Hedging...........................................................................................................................6
Installation of SMARTFOX current transformers
............................................................7
SMARTFOX Additional
current transformer
...................................................................8
Wiring diagram ........................................................................................................................9
Power controller & heating element 1-phase. ..........................................................9
Power controller & heating element 3-phase. ........................................................10
Consumer via relay.....................................................................................................11
Navigation through the menu
.............................................................................................12
Instructions for firmware update..................................................................................13
Displaying the measured values
........................................................................................14
Main menu...............................................................................................................................18
Settings menu .......................................................................................................................22
Settings General...........................................................................................22
Settings Network (LAN / WLAN)...............................................................................24
Settings Analogue output. ...........................................................................26
Settings relays 1-4......................................................................................................29
Settings Relay Special functions...............................................................33
Settings Inputs and consumption controller. ...........................................................36
Settings inverter, heat pump, battery.......................................................................38
Settings Car Charger..................................................................................................39
Maintenance menu .............................................................................................................40
Local Network access................................................................................................41
Connection with my.smartfox.at...................................................................................42
Troubleshooting ...................................................................................................................43
3

GENERAL INFORMATION
www.smartfox.at
General
Notes
These operating instructions are part of the scope of delivery. They contain the
information required for proper use. They are intended for electrical engineering
personnel or specialists who are familiar with the installation, assembly and
commissioning of the product described here. If further information is required, it
can be requested from the contact details on page 44.
Conformity
This appliance complies with the provisions of the Directive of the Council of the
European Communities on the approximation of the laws of the EC Member States
relating to electromagnetic compatibility, EMC Directive 2004/108/EC, and the Low
Voltage Directive 2006/95/EC.
Application
The "SMARTFOX Pro 2" energy consumption controller is used to optimise self-
consumption to a maximum in electrotechnical systems with self-power generation.
All relevant data for the application are measured, displayed and used for the
control. The measured values are stored if desired when a microSD card is
activated and shown on the 2-line (2x16 digits) display. Displayed measured values
are voltage L1 L2 L3 current L1 L2 L3 power L1 L2 L3 and the total currents and
powers. Calculated values are PNutz, work
, energy, regenerated energy. Other
values displayed are frequency, status of the
4 relays, date and time, SD card status,
SD card free memory, Ethernet IP and the MAC address.
Function
The currents to be measured are measured either directly via the supplied current
transformers or via additional current transformers. The voltage is always
measured directly (according to the connection diagram). The main function of the
unit is to detect the current surplus energy, calculated by U.I, and thus to control a
continuously controllable consumer with exactly this amount of energy. This is done
via the analogue outputs 0/1-10V or 0/4-20mA. In addition, 4 relay make contacts
with freely selectable power and switch-on times per day are available.
4

SCOPE OF DELIVERY & TECHNICAL
DATA
www.smartfox.at
Rated current
80A | 100A or via additional transformer
4995A
Connection
s
L1/L2/L3/N/PE 3xL 1xN 1xPE 1.5mm²
Relay 1-4 4x 2x1,5mm²
Analogue outputs pluggable Gnd/I+/V+/24VDC1mm²
Converter Pluggable 1xRJ12 6pol.
Communication
S0 input | CAN | RS485
Scope of delivery
1x SMARTFOX Pro 2 energy consumption
controller
1x Micro SD Card
1X Current transformer 3-phase up to 80A | 100A
Technical
data
SMARTFOX
Pro
Nominal voltage 3X230V/400V
Nominal frequency 50Hz
Overload continuous
Relay switching
capacity
Voltage max. 265V, current 260A
5A/250VAC |max. resistive
Consumer
Analogue outputs
0-10 VDC | 1-10VDC
0-20mA | 4-20mA
Interfaces
WLAN | 100Mbits/s Ethernet LAN
Temperature input PT1000
Voltage range 185-265V
Self-consumption 4W
View
2-line display here the current
values can be read by pressing the
keys.
Surge overload Voltage 1000V 65μs

SCOPE OF DELIVERY & TECHNICAL
DATA
www.smartfox.at
5

REGULATIONS
www.smartfox.at
EMC DIN EN61326
ATTENTION!
When connecting the voltage input variable, the assignment to the current
connection is important, i.e. the respective terminal of the voltage connection must
also be located in the outer conductor in which the current transformer is located.
Mechanical strength DIN EN 61010 Part 1
Accuracy, overload air
and creepage distance
connection
DIN EN 60688
DIN EN 61010 Part 1
DIN 43807
Dimensions
[WxHxD]
147mm x 90mm x 58 Width 8TE
Assembly
Top-hat rail mounting. At ambient temperatures of >45°C, however, a distance of
10mm is recommended. The mounting location should be as vibration-free as
possible and must not exceed an ambient temperature of 55°C.
Electrical
Connection
The regulations for the installation of electrical systems must be observed, according to
DIN 43807, via screw connection max. 1.5mm². When installing the current
Whe
n installing the current transformer, the correct current direction K and L must be
observed (K corresponds to the power supply company side, L corresponds to the
system side).
Hedging
Electrical safety
DIN EN 61010 Part
1
Housing with protective insulation,
protection class II, for
working voltages up to 600V
(mains to neutral) pollution degree 2,
measurement category CAT III
WARNING!
This unit may only be installed b y a qualified electrician, otherwise there is a risk of
fire or electric shock!
Protection class DIN EN 60529 Housing IP21
Disconnection DIN EN 61010 Part 1, 3, 3KV 50Hz 4s

REGULATIONS
www.smartfox.at
When connecting, ensure that a suitable back-up fuse is used (line protection). The
unit itself is internally fused.
6

INSTALLATION OF THE SMARTFOX CURRENT
TRANSFORMER
www.smartfox.at
0V +
24V 0V RX TX
CJG 441D 40A/I∆n0,03A G
K K
L L
L1 L2 L3 L1 L2 L3 N L2 L3 L1
Current
transformer
L1 L2 L3
0 0 5 7 3 4
8
M13 0122
kWh
Energy meter
L
L
L
L1 K
L2
K
L3
K
V20-C V20-C V20-C
PH
O
T
O
V
O
L
T
AI
K
Attention! The SMARTFOX current transformers must always be connected as
shown in the picture above. (Arrows point in the direction of the consumer).
Post-counter field
Counter field
Pre-counter field
7
L1
L2
L3
N
PE
R1
R2
R3
R4
K
L3
L
80A
K
L2
L
80A
K
L1
L
80A
K
L
3
L
K
L
2
L
K
L
1
L
80
A
80
A
80
A

SMARTFOX ADDITIONAL CURRENT
TRANSFORMER
www.smartfox.at
K
WARNING!
The SMARTFOX current transformer cable must not be cut (loss of warranty).
NOTE!
The SMARTFOX current transformer set can be extended up to 15m.
A suitable
current transformer extension must be used for
this
.
ADDITIONAL CURRENT
TRANSFORMER
L1
L2
L3 L
1.
SW divisible 200A with cable
ART NO. 0791732486490
2. SW 200A / 5A closed
ART NO. 0791732486636
3. SW 500A / 5A closed
ART NO. 0791732486667
4. SW divisible 500A / 5A with cable
ART NO. 0791732486650
CURRENT WALLER
SMARTFOX K
LKLK L
24V 0V RX TX
K K
L L
Current transformer extension
optional up to 15 m.
ART NO. 0791732486520
8
0003127
kWh
L
L
K
K
L1
L2
L3
N
PE
R1
R2
R3
R4
Table of contents
Popular Control Unit manuals by other brands

Festo
Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation
JS Automation MPC3034A user manual

JAUDT
JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum
Spektrum Air Module System manual

BOC Edwards
BOC Edwards Q Series instruction manual

KHADAS
KHADAS BT Magic quick start

Etherma
Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations
PMFoundations Attenuverter Assembly guide

GEA
GEA VARIVENT Operating instruction

Walther Systemtechnik
Walther Systemtechnik VMS-05 Assembly instructions

Altronix
Altronix LINQ8PD Installation and programming manual