SMA 485 Data Module User manual

485i-Module-IA-en-19 | Version 1.9 ENGLISH
Communication Interface for SMA Inverters
485 Data Module
Installation Manual

Legal Provisions SMA Solar Technology AG
2 485i-Module-IA-en-19 Installation Manual
Legal Provisions
The information contained in these documents is the property of SMA Solar Technology AG. Any publication, whether in whole or
in part, requires prior written approval by SMA Solar Technology AG. Internal reproduction used solely for the purpose of product
evaluation or other proper use is allowed and does not require prior approval.
SMA Warranty
You can download the current warranty conditions from the Internet at www.SMA-Solar.com.
Trademarks
All trademarks are recognized, even if not explicitly identified as such. Missing designations do not mean that a product or brand
is not a registered trademark.
The BLUETOOTH® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of these marks by
SMA Solar Technology AG is under license.
Modbus® is a registered trademark of Schneider Electric and is licensed by the Modbus Organization, Inc.
QR Code is a registered trademark of DENSO WAVE INCORPORATED.
Phillips® and Pozidriv® are registered trademarks of Phillips Screw Company.
Torx® is a registered trademark of Acument Global Technologies, Inc.
SMA Solar Technology AG
Sonnenallee 1
34266 Niestetal
Germany
Tel. +49 561 9522-0
Fax +49 561 9522-100
www.SMA.de
E-mail: info@SMA.de
© 2004 until 2016 SMA Solar Technology AG. All rights reserved.

SMA Solar Technology AG Table of Contents
Installation Manual 485i-Module-IA-en-19 3
Table of Contents
1 Information on this Document. . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1 Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 Skills of Qualified Persons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.3 Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 Scope of Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
3.1 Order Option 485 Data Module Pre-Installed in the Inverter . . . . . . . 8
3.2 Order Option 485 Data Module as Retrofit Kit . . . . . . . . . . . . . . . . . 8
4 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.1 485 Data Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.2 Type Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.3 Cable Gland . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.1 Device Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.2 Installing the 485 Data Module in the Inverter . . . . . . . . . . . . . . . . . 12
5.3 Connecting the 485 Data Module . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6 Decommissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.1 Disassembling the 485 Data Module . . . . . . . . . . . . . . . . . . . . . . . . 18
6.2 Packaging the 485 Data Module for Shipping. . . . . . . . . . . . . . . . . 19
6.3 Disposing of the 485 Data Module . . . . . . . . . . . . . . . . . . . . . . . . . 19
7 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
8 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
9 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

1 Information on this Document SMA Solar Technology AG
4 485i-Module-IA-en-19 Installation Manual
1 Information on this Document
Validity
This document is valid for device type "485I-MOD-G1 BGCB" with hardware version B5 and
firmware version 4.00 or higher.
Target Group
This document is intended for qualified persons. Only persons with the appropriate skills are allowed
to perform the activities described in this document (see Section2.2 "Skills of Qualified Persons",
page7).
Symbols
Symbol Explanation
Indicates a hazardous situation which, if not avoided, will result in death
or serious injury
Indicates a hazardous situation which, if not avoided, can result in death
or serious injury
Indicates a hazardous situation which, if not avoided, can result in minor
or moderate injury
Indicates a situation which, if not avoided, can result in property damage
Information that is important for a specific topic or goal, but is not
safety-relevant
☐ Indicates a requirement for meeting a specific goal
☑ Desired result
✖ A problem that might occur

SMA Solar Technology AG 1 Information on this Document
Installation Manual 485i-Module-IA-en-19 5
Typographies
Nomenclature
Abbreviations
Figures
The figures in this document can vary slightly for inverters of types STP 1x000TL-10,
STP xx000TLHE-10, STP xx000TLEE-10, STP xx000TL-30, SB x000TL-21 and WB xx00TL-21.
Typography Explanation Example
bold • Display texts
• Elements on a user interface
•Terminals
• Elements to be selected
• Elements to be entered
• The value can be found in the
field Energy.
• Select Settings.
•Enter the value 10 in the field
Minutes.
> • Connects several elements to
be selected
• Select Settings > Date.
[Button/Key] • Button or key to be selected or
pressed
• Select [Next].
Complete designation Designation in this document
Electronic Solar Switch ESS
PV System System
SMA Inverter Inverter
Abbreviation Designation Explanation
AC Alternating Current Alternating current
DC Direct Current Direct current

2 Safety SMA Solar Technology AG
6 485i-Module-IA-en-19 Installation Manual
2 Safety
2.1 Intended Use
The 485 Data Module enables the setup of cable-connected RS485 communication for
SMA inverters of type:
The 485 Data Module is only suitable for use with the above mentioned inverter types. The 485 Data
Module is available as a retrofit kit or is pre-installed in the inverter. The inverter still complies with the
standard after the product has been installed.
For safety reasons, it is not permitted to modify the product or install components that are not explicitly
recommended or distributed by SMA Solar Technology AG for this product. Only use the 485 Data
Module in accordance with the information provided in the enclosed documentation. Any other use
can result in personal injury or property damage.
The enclosed documentation is an integral part of this product.
• Read and observe the documentation.
• Keep the documentation in a convenient place for future reference.
Sunny Boy Sunny Tripower Windy Boy
SB 3000TL-20
SB 3600TL-20
SB 4000TL-20
SB 5000TL-20
SB 3000TL-21
SB 3600TL-21
SB 4000TL-21
SB 5000TL-21
SB 6000TL-21
SB 2500TLST-21
SB 3000TLST-21
STP 8000TL-10
STP 10000TL-10
STP 12000TL-10
STP 15000TL-10
STP 17000TL-10
STP 15000TLHE-10
STP 20000TLHE-10
STP 15000TLEE-10
STP 20000TLEE-10
STP 15000TL-30
STP 20000TL-30
STP 25000TL-30
WB 3600TL-20
WB 5000TL-20
WB 3000TL-21
WB 3600TL-21
WB 4000TL-21
WB 5000TL-21

SMA Solar Technology AG 2 Safety
Installation Manual 485i-Module-IA-en-19 7
2.2 Skills of Qualified Persons
The activities described in this document must only be performed by qualified persons. Qualified
persons must have the following skills:
• Training in the installation and commissioning of electrical devices and installations
• Knowledge of how to deal with the dangers and risks associated with installing and using
electrical devices and installations
• Knowledge of all applicable standards and directives
• Knowledge of how an inverter works and is operated
• Knowledge of and compliance with this document and all safety information
2.3 Safety Information
Electric Shock
Lethal voltages are present in the conductive parts of the inverter.
• Prior to performing any work on the inverter, disconnect the inverter from all voltage sources on
the AC and DC sides (see inverter installation manual).
Burn Hazards
Some parts of the inverter enclosure can get hot during operation.
• During operation, do not touch any parts other than the enclosure lid of the inverter.
Electrostatic Discharge
By touching electronic components, you can damage or even destroy the inverter through electrostatic
discharge (ESD).
• Ground yourself before touching any inverter component.
Interference in Data Transmission due to AC Cables
During operation, AC cables generate an electromagnetic field which may induce interference in
plant communication.
• Lay the RS485 communication cables using suitable fastening material and with a minimum
clearance of 50 mm to the AC cables.

3 Scope of Delivery SMA Solar Technology AG
8 485i-Module-IA-en-19 Installation Manual
3 Scope of Delivery
3.1 Order Option 485 Data Module Pre-Installed in the Inverter
Check the delivery for completeness and any visible external damage. Contact your distributor if the
delivery is incomplete or damaged.
Figure1: Components included in scope of delivery: 485 Data Module pre-installed in the inverter
3.2 Order Option 485 Data Module as Retrofit Kit
Check the delivery for completeness and any visible external damage. Contact your distributor if the
delivery is incomplete or damaged.
Figure2: Components included in the scope of delivery: 485 Data Module as retrofit kit
Position Quantity Designation
A 1 Installation Manual
B 1 Technical Description "RS485 Cabling Plan"
C 1 Cable gland
Position Quantity Designation
A 1 485 Data Module with:
• 2 conductive adhesive foil labels
•1 plug
• 1 plug with connected terminator
B 1 Cable gland
C 1 Installation Manual
D 1 Technical Description "RS485 Cabling Plan"

SMA Solar Technology AG 4 Product Description
Installation Manual 485i-Module-IA-en-19 9
4 Product Description
4.1 485 Data Module
The 485 Data Module enables the setup of wired RS485 communication for SMA inverters.
Figure3: Design of the 485 Data Module
4.2 Type Label
The type label clearly identifies the 485 Data Module. The type label is located at the bottom right
on the back of the 485 Data Module.
Figure4: Information on the type label
Position Designation
A Hexagon socket screw
B Plug-in connector
C Plug with connected resistor
DRibbon cable plug
E Ribbon Cable
FType label

4 Product Description SMA Solar Technology AG
10 485i-Module-IA-en-19 Installation Manual
You will require the information on the type label to use the 485 Data Module safely and when
seeking customer support from the SMA Service Line. The type label must remain permanently
attached to the 485 Data Module.
Symbol on the Type Label
4.3 Cable Gland
The cable gland provides a sturdy, tightly sealed connection of the cables to the inverter enclosure.
The cable gland also protects the inverter from dust and moisture intrusion.
Figure5: Product description: Cable gland
Position Designation Explanation
A Serial No. Serial number of the 485 Data Module
B Version Hardware version of the 485 Data Module
CType Device type
Symbol Designation Explanation
CE marking The 485 Data Module complies with the
requirements of the applicable EC
directives.
Position Designation
AFiller plug
BSeal
CSwivel nut
DCounter nut
Table of contents
Other SMA Control Unit manuals
Popular Control Unit manuals by other brands

Festo
Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation
JS Automation MPC3034A user manual

JAUDT
JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum
Spektrum Air Module System manual

BOC Edwards
BOC Edwards Q Series instruction manual

KHADAS
KHADAS BT Magic quick start

Etherma
Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations
PMFoundations Attenuverter Assembly guide

GEA
GEA VARIVENT Operating instruction

Walther Systemtechnik
Walther Systemtechnik VMS-05 Assembly instructions

Altronix
Altronix LINQ8PD Installation and programming manual