Slime 40058 User manual

PART#40058 | REV031918ART
ATTENTION! READ ALL INSTRUCTIONS CAREFULLY
FAILURE TO FOLLOW WARNING INSTRUCTIONS CAN RESULT IN FIRE,
PERSONAL INJURY OR PROPERTY DAMAGE.
SEALANT/
AIR HOSE
ENGLISH
REMOVABLE
DEBRIS CANISTER
EXPANDABLE
VACUUM HOSE
• Expands to 32.25 in.
(820mm) long
• Crevice/dusting tool
attachment included
BALL
CAUTION:
1. DO NOT run vehicle while inflator is operating. You may need to be in “accessory” or “on”
position. Please make sure emergency brake is set and car is in park.
2. Always ensure the valve connector is fully seated to depress the core of the valve stem for
proper inflation.
3. DO NOT use inflator continuously for more than 10 minutes. Allow unit to cool approximately 10
minutes between uses. Do not leave inflator unattended.
4. ALWAYS use a pressure gauge to check tire pressure. DO NOT overinflate.
5. Soft inflatables (i.e. rafts, balls, etc.) may not have recommended pressure markings. Be careful
not to inflate items beyond their capacity.
6. While operating, never block the inflator input or output.
7. Keep inflator out of reach of children.
8. For use with 12 volt DC power outlets rated 15 amps or higher. Do not use with older 8 amp
cigarette lighter receptacles.
EASY GRIP HANDLE
DIGITAL GAUGE
• 0-99PSI range
INFLATE RIGHT™
TECHNOLOGY
• Inflator automatically
shuts off when the set
pressure level is achieved
• Perfect pressure with
every use
CANISTER
RELEASE BUTTON
CONVENIENT
CORD STORAGE
POWER SOURCE
• Plugs into 12 volt,
15 amp power outlet
• 10 ft. (3m) length
POWER SWITCH
• Toggle between Vacuum/OFF/Inflator
INFLATABLES
VACUUM HOSE STORAGE
• Wraps around inflator
for easy storage.
VACUUM HOSE PORT
INFLATOR HOSE
STORAGE
CARS • TRUCKS • BIKES • INFLATABLES

INFLATION INSTRUCTIONS:
Inflation can be used for auto tires, bicycle tires, sports balls, rafts and other inflatables.
Plug power cord into 12 volt accessory power outlet.
Screw air hose connector onto tire’s valve stem.
Use the toggle switch to power the inflator by sliding
it to the inflator icon. Inflate tire to manufacturer’s
recommended air pressure. Use the Inflate Right
Technology ™ (instructions below) for accurate inflation.
1
2
3
4
When desired pressure* is reached, slide toggle switch
to middle “OFF” position to turn off inflator. UNPLUG
POWER CORD AND REMOVE AIR HOSE CONNECTOR.
INFLATE RIGHT™ TECHNOLOGY INSTRUCTIONS:
1. Once inflator hose is attached to the valve stem, hold the + or – button for approximately 2
seconds until the display flashes. Set the required pressure using the + or – buttons, then
wait 3 seconds. The display will stop flashing and show the target pressure value to which
the tire will be inflated. (Continuously pressing the + or – button will enter into “Fast setting
mode”, increasing or decreasing the rate of target pressure at an increased speed.)
2. Use the toggle switch to power the inflator by sliding it to the inflator icon to begin inflation.
3. When the pressure gauge reaches the pre-set value, the inflator will automatically stop
inflation. Once desired tire pressure is reached, disconnect the air hose, and unplug the
power cord.
* NOTE: Recommended tire pressure can be found in vehicle owner’s manual or on the
driver’s side door jamb.

VACUUM USAGE INSTRUCTIONS:
Remove expandable vacuum hose from base of unit, and
insert open end of the vacuum hose into the green suction
port on the back of the vacuum unit.
Plug power cord into 12 volt accessory power outlet.
The crevice/dusting tool accessory comes attached to the hose.
To use crevice tool, push in button lever located on side of
dusting tool and slide tool down. The crevice/dusting tool may
be removed from the hose if needed by pulling directly off of
the hose at base of the dusting tool attachment.
Use the toggle switch to power the vacuum by sliding it to the
vacuum icon. When finished using the vacuum, slide the toggle
switch to the middle “OFF” position to turn vacuum off and
unplug power cord. Disconnect the expandable vacuum hose
and place in the hose storage area on the base of the unit.
1
3
4
2

To Remove and Empty Debris Canister:
1
Press the debris canister release button located
under the handle and pull the debris canister
straight out, away from the unit.
To empty the canister, hold it over a trash
receptacle, and locate the green release button
on the bottom front of the canister. Depress
the button and shake out the debris until
canister is empty.
Reinstall the canister into the vacuum unit by
sliding the canister straight into the unit until
seated. An audible click will be heard when the
canister is seated properly.
VACUUM CANISTER REMOVAL INSTRUCTIONS:
3
4
When debris is removed, close the canister door
until green release button snaps closed.
2

INFLATOR TROUBLESHOOTING:
Inflator does not turn ON (try one or all of the following):
1. Check to see if the tire pressure set point on the digital gauge
is set to a lower PSI than your tire currently is reading (i.e., the
digital gauge is set to 15PSI, but your tire is at 20PSI; in this
scenario, the inflator will not turn on). Refer to the digital
gauge operating instructions and set the PSI to the correct
tire pressure.
2. Check the power plug and push it firmly into the receptacle,
twist back and forth.
3. Check receptacle and plug terminals for dirt, or debris.
(Use a non-conductive probe, not fingers or metal).
4. Check vehicle power outlet fuse. It should be 15 amps minimum.
5. Check the fuse. It may have blown:
12V fuse is located in the plug adaptor:
unscrew the tip, remove fuse, and inspect.
If necessary, replace fuse with 15A 250V 5mm x 20mm.
Inflator runs but does not inflate:
1. Be sure the connector is fully tightened on the valve stem.
2. Check tire for leaks, and check hose for breaks and leaks at fittings.
Inflator runs slowly:
1. Overheated from excessive use. Shut if off and allow to cool for 25 minutes.
2. Voltage too low. Check condition of vehicle battery.
NOTE:
If tire is totally deflated, it is possible that the tire could separate from the rim allowing air to leak
out when trying to inflate. In the event this occurs, you will have to jack up the tire prior to inflation.
CAUTION: Keep inflator out of reach of children. Do not over-inflate.
Dispose of this product at an e-waste recycling collection point or facility. Do not place in the trash or
standard recycling receptacle.
IDEAL USES
TIRE INFLATION TIME
CUBIC INCHES PER MIN.
AIR HOSE LENGTH
POWER CORD LENGTH
POWER SOURCE
LIGHT
DIGITAL GAUGE
VACUUM HOSE LENGTH
TOTAL REACH
Tires, Inflatables, Sports Balls
6min*
1000 CIM (16.4LPM)
2ft. (0.6m)
10 ft. (3m)
12 accessory outlet
Single LED, 7lumens
Digital Gauge 0-99 PSI
32.25 in. (820 mm) expanded
Inflator 12 ft. (3.66m) Vacuum 12.5 ft. (3.81m)
TECH SPECS
* (0-35PSI, Standard Tire: P195/65 R15)

Warranty: For the period of one year from date of purchase, manufacturer guarantees that this
Product will meet the specifications when used as directed. Manufacturer’s sole liability and
Customer’s sole remedy under any warranty claim is limited to a Manufacturer’s coupon for a
replacement product upon return of unit and proof of purchase.
QUESTIONS OR COMMENTS: Call 1-888-457-5463 or visit www.slime.com
ITW Global Tire Repair • 125 Venture Drive, Suite 210, San Luis Obispo, CA 93401 USA
Slime® is a trademark of Illinois Tool Works, Inc., registered in the U.S. and other countries.
VACUUM TROUBLESHOOTING:
Vacuum does not turn ON (try one or all of the following):
1. Check the power plug and push it firmly into the receptacle, twist back and forth.
2. Check receptacle and plug terminals for dirt, or debris. (Use a non-conductive probe, not fingers
or metal).
3. Check vehicle power outlet fuse. It should be 15 amps minimum.
4. Check the fuse. It may have blown: 12V fuse is located in the
plug adaptor: unscrew the tip, remove fuse, and inspect.
If necessary, replace fuse with 15A 250V 5mm x 20mm.
Vacuum is not picking up debris (try one or all of the following):
1. There may be an object lodged in the vacuum hose, vacuum accessory tip, or vacuum unit itself.
Unplug from power, remove the vacuum hose and inspect to ensure the unit is clear of blockages.
Check the vacuum accessory tip for blockage. If no blockage is found in the hose or tip, check the unit
itself for blockage. The debris canister should be removed, and the suction port inspected from both
sides. If debris is determined to be stuck in the unit, use a thin flexible item (such as a drinking straw)
to remove it. Do not use sharp objects that could damage the unit.
2. The debris canister may not be correctly seated in unit. Remove the debris canister from unit by
pulling the debris canister straight out, away from the unit. Reinstall the canister into the vacuum
unit by pushing the canister straight into the unit until seated. An audible click will be heard when
the canister is seated properly.
3. The vacuum filter may be dirty, restricting flow. To clean, remove the debris canister from unit by
pulling the debris canister straight out, away from the unit. Open the top lid, and pull out the green
filter retainer. Remove the foam filter from the filter retainer, and rinse both pieces thoroughly with
warm water until clean. Allow parts to fully dry, and reassemble.
FILTER RETAINER
CANISTER
Other manuals for 40058
1
Table of contents
Other Slime Power Tools manuals