Site Digital Angle Finder User manual

1
Digital Angle Finder
Item No. 25814
INSTRUCTION MANUAL
Please read and retain for future reference.
FIG. 1
1. Fold-out leg 10. End cap/battery lid
2. Joint cover 11. Contact edge
3. Base leg DISPLAY ELEMENTS
4. “ON/OFF” button a. Reading
5. “Mitre” button b. Low battery indicator
6. “HOLD” button c. Mitre(MTR) indicator
7. LCD Display d. Hold(HOLD) indicator
8. Spirit level for horizontal alignment
9. Spirit Level for vertical alignment

2
Safety Rules for Digital Angle Finder
Warning: avoid sharp edges. Be careful in handling, may cause laceration.
Caution: the angle finder is a precision measuring instrument. Dropping or
banging the device may result in impaired function or future inaccurate
readings.
Technical Data
Measuring range --------------------------------------------------- 0° to 220°
Measuring accuracy
Angle ------------------------------------------------------------- ±0.5°(9mm/m)
Spirit Level ------------------------------------------------------ ±0.029°(0.5mm/m)
Lowest indication unit --------------------------------------------- 0.1°
Operating temperature -------------------------------------------- 0℃- 50℃
Storage temperature ----------------------------------------------- 20℃to 85℃
Battery ----------------------------------------------------------------- 1 x 9V (Not Included)
Operating lifetime --------------------------------------------------- Approx. 50h
Automatic switch –Off after approx -------------------------- 5 min
Leg to leg length --------------------------------------------------- 450 mm
Weight according to EPTA-Procedure 01/2003 ------------ 1.1lb
Preparation
INSERTING/REPLACE THE
BATTERY (FIG. 2)
Use only 9V battery
To open the end cap/battery lid (10),
remove two screws and pull out end cap.
Insert the battery onto terminal and re-install
end cap and screws.
●When the LOW BAT (battery) indicator (b)
appears in the display for the first time,
measurements are still possible but accuracy
may be reduced, please replace battery.
●IF THE MEASURING TOOL IS NOT USED
FOR A LONG PERIOD OF TIME, THE
BATTERY MUST BE REMOVED. The

3
battery will corrode or discharge itself over long periods.
FIG. 2
SWITCHING ON AND OFF
Press the “ON/OFF” button (4) to turn the measuring tool on or off. After
approximately 5 minutes without the button activation or angle change, the
measuring tool shuts off automatically to preserve battery life.
Operation Instructions
MEASURING ANGLES (FIG. 3)
Position the fold-out leg (1) and the base leg
(3) plane against the edges to be measured.
The displayed reading corresponds with the
internal angle (w) between the base leg and
the fold-out leg.
The reading is indicated on the display until
the legs are moved in relation to each other.
RETAINING THE MEASURED VALUE (HOLD) FIG. 3
The current reading can be retained in the display by pressing the HOLD
button (6).
When the hold mode is activated, “HOLD” d is indicated in the display. The
reading remains unchanged (even when the legs are moved in relation to each
other) until the HOLD button (6) is pressed again.
TRANSFERRING ANGLE TO MITRE ANGLES (FIG. 4)
Position the measuring tool with the fold-out leg (1) or with base leg (3) against
the angle you want to measure. Adjust the required angle with the other leg
and project the angle onto the workpiece.
When directly projecting a measured angle
onto a workpiece, pay attention that the
fold-out leg (1) and base leg (3) don’t move.
After pressing the HOLD button (6), which
stores the measured angle, the user can
now activate the MTR (mitre) button (5). By
pressing the MTR button (5), the Angle
Finder is taking the measured angle and
converting it to the correct Mitre Cut Angle.

4
This measurement is what you need to set your mitre saw in order to create
the correct cut.
FIG. 4
Maintenance and Service
For safe and proper working, always keep the measuring tool clean.
Do not immerse the measuring tool into water or other fluids.
Wipe off debris using a moist and soft cloth.
Do not use any cleaning solvents.
If the measuring tool should fail despite the care taken in manufacturing and
testing procedures, repair should be carried out by an authorized after-sales
service centre for this tool.
In all correspondence and spare parts orders, please always include the
10-digit article number given on the type plate of the measuring tool.
DISPOSAL
Multi-detectors, accessories and packaging should be sorted for
environments-friendly recycling.
Environmental Protection
Waste electrical products should not be thrown away with
household waste.
Please recycle where facilities exist.
Check with your local authority or retailer for recycling advice.

5
Declaration of Conformity
We
SITE (UK) Ltd., BA22 8RT
Declare that the product
(Digital Angle Finder, EPT-DAF)
complies with the essential health and safety requirements of the following
Directives:
(EMC Directive 89/336/EEC)
Standards and technical specifications referred to:
(EN61326/A3:2003)
Authorised Signatory
Name: Peter Harries
Quality Assurance Manager
Date (12/04/07)
This manual suits for next models
1
Table of contents
















