Sirona XIOS XG Operating instructions

kÉï=~ë=çÑW=
léÉê~íáåÖ=fåëíêìÅíáçåë=~åÇ=fåëí~ää~íáçå
MVKOMNS
uflp=ud=rp_=ãçÇìäÉ=~åÇ=ëÉåëçêë
båÖäáëÜ
=
båÖäáëÜ
Operating instructions and installation, XIOS XG USB module and sensors
XIOS XG Select
XIOS XG Supreme


64 09 713 D3610
D3610.201.01.08.02 09.2016 3
Sirona Dental Systems GmbH Table of contents
Operating Instructions and Installation XIOS XG USB module and sensors
båÖäáëÜ
Table of contents
1General information................................................................................................. 6
1.1 Dear Customer, ............................................................................................ 6
1.2 Contact information ...................................................................................... 6
1.3 General information about this operating manual ........................................ 7
1.4 Other valid documents ................................................................................. 7
1.5 Intended use................................................................................................. 7
1.6 Indications and contraindications ................................................................. 8
1.7 Structure of the document ............................................................................ 9
1.7.1 Identification of the danger levels.................................................... 9
1.7.2 Formats and symbols used ............................................................. 9
2Safety instructions ................................................................................................... 10
2.1 Qualifications of operating personnel........................................................... 10
2.2 Hygiene ........................................................................................................ 10
2.3 Radiation protection ..................................................................................... 10
2.4 PC system and software .............................................................................. 10
2.5 Allocation of acquisition system to patient.................................................... 10
2.6 Trouble-free operation.................................................................................. 11
2.7 Maintenance................................................................................................. 11
2.8 Changes and extensions to the device ........................................................ 11
2.9 Combination with other units........................................................................ 11
2.10 Radiotelephones .......................................................................................... 12
2.11 Electrostatic discharge ................................................................................. 12
3System description .................................................................................................. 14
3.1 System structure .......................................................................................... 14
3.2 USB module ................................................................................................. 16
3.3 USB cable .................................................................................................... 16
3.4 Sensors ........................................................................................................ 17
3.5 Sensor holder systems................................................................................. 17
3.5.1 Single-use sensor holder system .................................................... 17
3.5.2 Aimright reusable sensor holder system ......................................... 18
3.6 Intraoral X-ray tube assembly ...................................................................... 19
3.7 PC system .................................................................................................... 20
3.8 USB hub (optional)....................................................................................... 21
3.9 Technical data .............................................................................................. 22

64 09 713 D3610
4D3610.201.01.08.02 09.2016
Table of contents Sirona Dental Systems GmbH
Operating Instructions and Installation XIOS XG USB module and sensors
3.10 Certification, registration and standards........................................................ 23
3.11 Symbols ........................................................................................................ 24
3.12 Position of the labels ..................................................................................... 25
4Installation ................................................................................................................ 26
4.1 Fitting a second protective ground conductor on the PC .............................. 26
4.2 Install the PC software .................................................................................. 28
4.3 Connect USB module and hub...................................................................... 29
4.4 Install holder for the USB module ................................................................. 31
4.5 Connect sensor ............................................................................................. 32
4.6 Complete test exposures/acceptance tests .................................................. 32
5Operation.................................................................................................................. 33
5.1 Enable exposure readiness........................................................................... 33
5.2 Determine unit status .................................................................................... 36
5.3 Sliding the hygienic protective sleeve over the sensor ................................. 37
5.4 Position the sensor........................................................................................ 38
5.4.1 Position sensor with single-use sensor holder system..................... 39
5.4.1.1 Anterior tooth exposure ..................................................... 39
5.4.1.2 Posterior tooth exposures ................................................. 40
5.4.1.3 Bite wing exposures .......................................................... 41
5.4.1.4 Endodontics exposures with the half-angle technique ......42
5.4.1.5 Measurement exposure for endodontics ........................... 43
5.4.2 Position sensor with Aimright reusable sensor holder system ......... 44
5.4.2.1 Anterior tooth exposure ..................................................... 44
5.4.2.2 Posterior tooth exposures ................................................. 48
5.4.2.3 Horizontal bite wing exposures ......................................... 51
5.5 Select the exposure parameters for the X-ray tube assembly ...................... 53
5.5.1 X-ray doses and image quality......................................................... 53
5.5.2 Recommended dose for XIOS XG sensors ..................................... 53
5.5.3 HELIODENT Plus exposure times ................................................... 54
5.5.3.1 Pre-programmed exposure times for XIOS XG sensors
with 200 mm (8") FHA cone
54
5.5.3.2 Pre-programmed exposure times for XIOS XG sensors
with 300 mm (12") FHA cone (round or square cone)
55
5.6 Releasing the exposure ................................................................................ 56
5.7 Removing the hygienic protective sleeve from the sensor............................ 57
5.7.1 With single-use sensor holder system ............................................. 57
5.7.2 With Aimright reusable sensor holder system.................................. 59
5.8 Alignment of the X-ray image........................................................................ 60

64 09 713 D3610
D3610.201.01.08.02 09.2016 5
Sirona Dental Systems GmbH Table of contents
Operating Instructions and Installation XIOS XG USB module and sensors
båÖäáëÜ
6Maintenance and inspection.................................................................................... 61
6.1 Hygiene ........................................................................................................ 61
6.1.1 Care, cleaning agents, and disinfectants ........................................ 61
6.1.2 USB module and sensors................................................................ 62
6.1.3 Sensor holders ................................................................................ 63
6.2 Regular inspections...................................................................................... 64
6.3 Replace the sensor cable............................................................................. 66
7Consumables and spare parts................................................................................. 69
8Electromagnetic compatibility.................................................................................. 73
8.1 Accessories .................................................................................................. 73
8.2 Electromagnetic emission ............................................................................ 73
8.3 Interference immunity................................................................................... 74
8.4 Working clearances...................................................................................... 76
9Disposal................................................................................................................... 77

64 09 713 D3610
6D3610.201.01.08.02 09.2016
1General information Sirona Dental Systems GmbH
1.1Dear Customer, Operating Instructions and Installation XIOS XG USB module and sensors
1General information
1.1 Dear Customer,
We are pleased that you have equipped your practice with the digital
Intraoral X-ray system XIOS XG from Sirona. The system is characterized
by many features including outstanding image quality and a high day-to-
day reliability.
XIOS XG can be operated with two types of sensor – the XIOS XG Select
and XIOS XG Supremesensors. Both types of sensor are available in
three sizes (0, 1 and 2). By using XIOS XG Supreme sensors enhanced
image processing functions are available to you in SIDEXIS XG /
SIDEXIS 4 through special filters. Depending on the indication you can
apply the corresponding filter to the X-ray image in order to amplify the
relevant structures. XIOS XG Supreme sensors offer higher resolution
compared with XIOS XG Select sensors.
In addition to SIDEXIS XG / SIDEXIS 4 (SIDEXIS XG version 2.5.6 and
above) the SIDEXIS plug-in must be installed for XIOS XG. Information
on the PC software can be found in the "SIDEXIS Plug-in for XIOS
XGOperator's Manual".
This operating manual should be of good help to you before use as well
as serve anytime later as a reference material.
We wish you a great deal of success and pleasure with XIOS XG.
Your XIOS XG Team
1.2 Contact information
Worldwide customer service
Customer service center In the event of technical queries, please use our online contact form at
www.sirona.com. In the navigation bar, go to the menu commands
"CONTACT"
/
"Customer Service Center"
and then click the
"CONTACT
FORM FOR TECHNICAL QUESTIONS"
button.
Authorized agent in the EU
Sirona Dental Systems GmbH
Fabrikstrasse 31
64625 Bensheim
Germany
Tel.: +49 (0) 6251/16-0
Fax: +49 (0) 6251/16-2591
e-mail: [email protected]
www.sirona.com
Manufacturer's address
Sirona Dental, Inc
30-30 47th Ave
Long Island City
New York, 11101
U.S.A.

64 09 713 D3610
D3610.201.01.08.02 09.2016 7
Sirona Dental Systems GmbH 1General information
Operating Instructions and Installation XIOS XG USB module and sensors 1.3General information about this operating manual
båÖäáëÜ
1.3 General information about this operating manual
Observe theOperating Instructions
Observe the Operating Instructions Please familiarize yourself with the unit by reading through these
Operating Instructions before putting it into operation. It is essential that
you comply with the specified warning and safety information.
Keep documents safe Always keep the Operating Instructions handy in case you or another
user require(s) information at a later point in time. Save the Operating
Instructions on the PC or print them out.
If you sell the unit, make sure that the Operating Instructions are included
with it either as a hard copy or on an electronic storage device so that the
new owner can familiarize himself with its functions and the specified
warning and safety information.
Online portal for technical documents We have set up an online portal for the Technical Documents at http://
www.sirona.com/manuals. From here, you can download these
Operating Instructions along with other documents. Please complete the
online form if you would like a hard copy of a particular document. We will
then be happy to send you a printed copy free of charge.
Help If you continue to have difficulties despite having thoroughly studied the
Operating Instructions, please contact your dental depot.
1.4 Other valid documents
The X-ray system includes other components, such as PC software,
which are detailed in other documents. Instructions and warning and
safety information provided in the following documents must be taken into
account:
● SIDEXIS 4 Installation Instructions
● SIDEXIS 4 User Manual
● SIDEXIS XG Installation Instructions
● SIDEXIS XG Operator's Manual
● SIDEXIS Plug-in for XIOS XG Operator's Manual
Keep these documents handy at all times (file them in the X-ray System
Logbook in the FR of Germany).
The system integrator must complete the enclosed declaration of
conformity.
To safeguard your warranty claims, please complete the attached
"Installation Report / Warranty Passport" together with the service
engineer immediately after the installation of your unit.
1.5 Intended use
The XIOS XG X-ray system is designed for digital acquisition of intraoral
X-ray images for diagnostic purposes. The system is used on patients by
dental professionals. The digital images produced are transferred to a PC
and displayed on a monitor. The images can be edited, saved and printed
on the PC.
The product must not be operated in hazardous areas.

64 09 713 D3610
8D3610.201.01.08.02 09.2016
1General information Sirona Dental Systems GmbH
1.6Indications and contraindications Operating Instructions and Installation XIOS XG USB module and sensors
1.6 Indications and contraindications
Indications in the areas:
● Conservative dentistry
● Caries diagnosis, especially of proximal lesions
● Endodontics
● Periodontology
● Prosthodontics
● Functional diagnosis and treatment of craniomandibular dysfunctions
● Surgical dentistry
● Implantology
● Oral and maxillofacial surgery
● Orthodontics
Contraindications:
● Display of cartilage structures
● Display of soft tissue

64 09 713 D3610
D3610.201.01.08.02 09.2016 9
Sirona Dental Systems GmbH 1General information
Operating Instructions and Installation XIOS XG USB module and sensors 1.7Structure of the document
båÖäáëÜ
1.7 Structure of the document
1.7.1 Identification of the danger levels
To prevent personal injury and material damage, please observe the
warning and safety information provided in these operating instructions.
Such information is highlighted as follows:
Tip: Information on making work easier.
1.7.2 Formats and symbols used
The formats and symbols used in this document have the following
meaning:
DANGER
An imminent danger that could result in serious bodily injury or death.
WARNING
A possibly dangerous situation that could result in serious bodily injury
or death.
CAUTION
A possibly dangerous situation that could result in slight bodily injury.
NOTICE
A possibly harmful situation which could lead to damage of the product
or an object in its environment.
IMPORTANT
Application instructions and other important information.
Prerequisite
1. First action step
2. Second action step
or
➢Alternative action
Result
➢Individual action step
Prompts you to do something.
See "Formats and symbols
used [ → 9]"
Identifies a reference to another text
passage and specifies its page
number.
● List Designates a list.
"Command / menu item" Indicates commands, menu items or
quotations.

64 09 713 D3610
10 D3610.201.01.08.02 09.2016
2Safety instructions Sirona Dental Systems GmbH
2.1Qualifications of operating personnel Operating Instructions and Installation XIOS XG USB module and sensors
2Safety instructions
2.1 Qualifications of operating personnel
The system may only be operated by skilled or properly trained
personnel.
Personnel undergoing education or training, or who are using the unit as
part of general training may only operate the unit under the constant
supervision of an experienced person.
2.2 Hygiene
Suitable hygienic measures must be taken to prevent cross
contamination between patients, users and other persons.
The hygienic protective sleeves and sensor holder tabs are single use
devices which must be renewed for each patient. Do not use single use
devices more than once.
The sterilizable exposure accessories such as the rods and rings of the
XIOS XG sensor holder must be sterilized to prevent any possible
transmission of infective agents which might under certain circumstances
cause serious illnesses.
The sensors and the cable must be disinfected before each patient. Refer
to Hygiene.
2.3 Radiation protection
The valid radiation protection regulations and measures must be
observed. The statutory radiation protection equipment must be used.
Please follow the manual for your X-ray tube assembly.
2.4 PC system and software
During the exposure, the data connection and power supply must be
ensured via the USB port. Under Power Options on the control panel set
the PC so that it never switches to stand-by operation or goes to sleep.
SIDEXIS XG / SIDEXIS 4 may not be terminated until the end of the
exposure. Before image acquisition, close all programs that are not
required for the operation of SIDEXIS XG / SIDEXIS 4. Any programs
running in the background, such as media players, print managers,
backup software, etc., may cause SIDEXIS XG / SIDEXIS 4 to crash
during the exposure. In cases of doubt, consult your system
administrator.
These operating instructions presuppose that you are familiar with the
use of the SIDEXIS XG / SIDEXIS 4software.
2.5 Allocation of acquisition system to patient
During routine practice, the clear allocation of the acquisition system to
the patient to be examined is ensured. This also applies to the allocation
of the X-rays to the patient data stored by SIDEXIS XG / SIDEXIS 4.
Table of contents
Popular Control Unit manuals by other brands

Festo
Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation
JS Automation MPC3034A user manual

JAUDT
JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum
Spektrum Air Module System manual

BOC Edwards
BOC Edwards Q Series instruction manual

KHADAS
KHADAS BT Magic quick start

Etherma
Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations
PMFoundations Attenuverter Assembly guide

GEA
GEA VARIVENT Operating instruction

Walther Systemtechnik
Walther Systemtechnik VMS-05 Assembly instructions

Altronix
Altronix LINQ8PD Installation and programming manual