Sinclair DRY CONTACT GATEWAY SDG-01 User manual

DRY CONTACT GATEWAY
SDG-01
USER'S MANUAL
EN

“Originalinstructions”
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.

I
To Users
Thank
you
for
selecting Sinclair’s
product.
Please
read
this
instruction
manual
carefully before installing and using the product, so as to master and correctly
use the
product.
In
order
to
guide
you
to
correctly
install
and
use
our
product
and
achieve
expected operating effect, we hereby instruct as below:
(1) This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsibility for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
(2) This instruction manual is a universal manual; some functions are only
applicable to particular product. All the illustrations and information in the
instruction manual are only for reference, and control interface should be
subject to actual operation.
(3) In order to make the product better, we will continuously conduct
improvement and innovation. We have the right to make necessary revision
to the product from time to time due to the reason of sales or production,
and reserve the right to revise the contents without further notice.
(4) For personal injury or property loss and damage caused by improper

II
operation such as improper installation and debugging, unnecessary
maintenance, violation of related national laws and rules and industrial
standard, and violation of this instruction manual, etc., we will bear no
liability.
(5) The
final
right
to
interpret
for
this
instruction
manual
belongs
to
SINCLAIR CORPORATION Ltd..

III
Contents
1 Safety Notices (Please be sure to abide).................................. 1
2 Appearance..................................................................................... 2
3 DIP switch instruction.................................................................... 4
4 Functions......................................................................................... 5
4.1 Shield general terminals................................................................... 5
4.2 Input function...................................................................................... 5
4.2.1 Level input ............................................................................... 5
4.2.2 Impulse input........................................................................... 6
4.3 Output function................................................................................... 7
4.4 Indicator instruction ........................................................................... 8
5 Product Installation........................................................................ 9
5.1 Dimension........................................................................................... 9
5.2 Installation requirement................................................................... 10
5.3 Wire specification............................................................................. 10
5.4 Wiring instruction ............................................................................. 11
5.4.1 Communication and power cord connection.................... 11
5.4.2 Connection of input dry contact.......................................... 11
5.4.3 Connection of output dry contact........................................ 11
5.4.4 Installation procedure........................................................... 12

1
1 Safety Notices (Please be sure to abide)
Warning: If not abide strictly, it may cause severe damage to the unit or
the people.
Note: If not abide strictly, it may cause slight or medium damage to the unit
or the people.
This sign indicates that the operation must be prohibited. Improper
operation may cause severe damage or death to people.
This sign indicates that the items must be observed. Improper operation
may cause damage to people or property.
WARNING!
This product can’t be installed at corrosive, inflammable or explosive
environment or the place with special requirements, such as kitchen. Otherwise,
it will affect the normal operation or shorten the service life of the unit, or even
cause fire hazard or serious injury. As for above special places, please adopt
special air conditioner which is with anti-corrosive or anti-explosion function.

2
2 Appearance
Fig. 2.1 Appearance of dry contact gateway

3
Fig. 2.2 Main board of dry contact gateway
Table 2.1 Instruction of main board
No. Components No. Components
1 4-core needle stand (common
use for communication and
power supply) 7 DIP switch S1
2 Force OFF dry contact input
terminal block 8 ON/OFF dry contact output
terminal block
3 ON/OFF dry contact input
terminal block 9 Error indicator dry contact
output terminal block
4 Mode dry contact input terminal
block 10 Mode dry contact output
terminal block
5 Reserved terminal block 11 Cold plasma dry contact
output terminal block
6 DIP switch S2 12 Ventilation dry contact output
terminal block

4
3 DIP switch instruction
Two DIP switches S1 and S2 are installed on the dry contact gateway. Before
energization, please set to proper position according to requirement. Once
energization is finished, please do not dial any DIP switch. As for the function
definition for DIP switch S1 and S2, please refer to table 3.1 and table 3.2.
Table 3.1 Function for DIP switch S1
Dip switch bit 1 2 3 4 5 6 7
Description General terminals
control enable Input
type Reserved
ON position Enable Level /
Digital position Disable Impulse /
Table 3.2 Function for DIP switch S2
Dip switch bit 1 2 3 4 5 6 7
Input name Force OFF ON/OFF Mode Reserved
ON position Enable Enable Enable /
Digital position Disable Disable Disable /

5
4 Functions
4.1 Shield general terminals
Once the first bit of DIP switch S1 is set to Digital position (General terminals
control disable), the unit will shield the general terminals (wired controller, remote
controller, APP and light board), and high-end terminals (central controller,
long-distance monitor, keycard control) and dry contact gateway can still control the
unit. When the first bit of DIP switch S1 is set to ON position (General terminals
control enable), all the terminals can control the unit.
4.2 Input function
Dry contact gateway is compatible with level input method and impulse input
method, which can be selected by the second bit of DIP switch S1. Each input
function can be set as enable or disable through the corresponding bit of DIP switch
S2. When it is set as disable, the unit won’t execute corresponding input command.
The following descriptions of input functions are supposed as the input functions are
enabled.
4.2.1 Level input
Under level input method, the input command is decided by the
Connected/Disconnected of the dry contact. Each time when the status of dry contact
is changed, input commands of all the dry contacts will be re-executed. The
Table of contents
Other Sinclair Gateway manuals
Popular Gateway manuals by other brands

LST
LST M500RFE-AS Specification sheet

Kinnex
Kinnex Media Gateway quick start guide

2N Telekomunikace
2N Telekomunikace 2N StarGate user manual

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Original instructions

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE user guide

Telsey
Telsey CPVA 500 - SIP Technical manual