Simu T3.5Hz02 User manual

EN T3.5Hz02/T5Hz02/T6Hz02
(230V~50Hz)
EN- ORIGINAL INSTRUCTIONS
S.A.S. au capital de 5 000 000 !- Z.I. Les Giranaux - BP71 - 70103 Arc-Les-Gray CEDEX - RCS GRAY B 425 650 090 - SIRET 425 650 090 00011 - n° T.V.A CEE FR 87 425 650 090
Installation
1
47
583
653
657
596
666
670
619
689
693
437 460 475
472 495 510
Instructions which must be followed by the drive and home automation professional installing the drive:
- Methods of wiring are given by national standards or IEC60364 standard.
- Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
- T5Hz02: The cable for the T5Hz02 can be removed. If it is damaged, replace by the same. The cable may only be
connected to the motor by qualied personnel. The connector is to be assembled without damaging the contacts. The
continuity of the earth connection must be ensured.
- T3.5Hz02 - T6Hz02: The cable for the T3.5Hz02 - T6Hz02 cannot be removed. If it is damaged, return the drive to the
After-Sales department.
Recommendations:
- Keep a minimum distance of 20 cm between two Hz.02 motors.
- Keep a minimum distance of 30 cm between Hz.02 motors and Hz transmitters. A radio appliance using the same
frequency (433,42MHz) may deteriorate our product’s performance (ex.: hi- radio headphones).
These instructions apply to all T3.5Hz02/T5Hz02/T6Hz02 drive, the different versions of which are available in the current
catalogue.
Field of application: T3.5Hz02/T5Hz02/T6Hz02 drive are designed to all types of roller shutters, outdoor awnings without
cassette. The installer, who must be a motorisation and home automation professional, must ensure that the drive product
is installed in accordance with the standards in force in the country in which it is installed such as EN 13659 relating to roller
shutters, EN 13561 relating to outdoor screens and awnings.
Liability: Before installing and using the drive, please read operating and installation guide carefully. Please read these
instructions carefully before installing and using the drive. In addition to following the instructions given in this guide, the
instructions detailed in the attached Safety instructions document must also be observed. The drive must be installed
by a motorisation and home automation professional, according to instructions from SIMU and the regulations applicable
in the country in which it is commissioned. It is prohibited to use the drive outside the eld of application described above.
Such use, and any failure to comply with the instructions given in this guide and in the attached Safety instructions
document, absolves SIMU of any liability and invalidates the warranty. The installer must inform its customers of the
operating and maintenance conditions for the drive and must provide them with the instructions for use and maintenance,
and the attached Safety instructions document, after installing the drive. Any After-Sales Service operation on the drive
must be performed by a motorisation and home automation professional. If in doubt when installing the drive, or to obtain
additional information, contact a SIMU adviser or go to the website www.simu.com.
- Drilling of the tube:
1/5
5010945L
EN

2
3
5
4
T6Hz02 : 9910062
Nm ≥ 60 & ALUMINIUM WHEEL
2
3
5
4
T5Hz02 : 9910004
ALUMINIUM WHEEL
T5Hz02 T3.5Hz02T6Hz02
- Assembly:
5.3 Nm max
2/5
Compatible transmitters
3
End limit adjustment
4
- Attach cables to prevent any contact with moving parts.
- If the motor is used outdoors and if the power supply cable is of the H05-VVF type, then run the cable in a UV-resistant conduit,
e.g. trunking.
Wiring
2
You must have the possibility to switch off individually each motor.
If the installation includes several motors, only one motor is to be powered during this programming
procedure. It will eliminate interferences with the other motor during the procedure.
PE
L
NT3.5Hz02
PE
L
N
T5Hz02 - T6Hz02
230V ~ 50 Hz230V ~ 50 Hz
1: 1/5 channels Wall Hz transmitter/ Memory Hz
2: 1/5 channels Mobile Hz transmitter
3: Color Multi 16 / Timer Easy / Timer Multi transmitters
4: Hz Sun sensor
Location of the PROG key on Hz transmitters:
Do not position the transmitter near metal in order to avoid
range losses.
1 2 3 4
(12 transmitters max. for one motor)
EN

3/5
- Press the transmitter PROG Key for approximately 1 second. The
motor will run for 0,5 second in one direction and then in the other.
Your transmitter is now programmed to control the motor in stable
mode.
4- After the adjustment of the DOWN (a) and the UP (b) end limits, conrm the settings:
- Press 2s on the "STOP" key to validate the settings. The motor will stop and will run
for 0,5 second in one direction and then in the other. Go to next step.
Programming the rst individual point of control
5
This operation can only be performed from the transmitter that was used for operation 4.1.
If you do not want to use this transmitter as the individual control:
- cut the power supply (2 seconds minimum).
- repeat the opération 4.1* with a new transmitter and then go to step §5.
* In this case, the motor will run for 0,5 second in both directions, that means the limits setting is already done.
1- Position the motor on the DOWN end limit using the
"DOWN" and "UP" keys.
2- To memorize the DOWN end limit position, press
simultaneously the "STOP" and "UP" keys. The motor
will run automatically in the UP direction.
3- Before the motor reaches the UP end limit, press the
"STOP" key.
1- Position the motor on the UP end limit using the "UP"
and "DOWN" keys.
2- To memorize the UP end limit position, press
simultaneously the "STOP" and "DOWN" keys. The
motor will run automatically in the DOWN direction.
3- Before the motor reaches the DOWN end limit, press
the "STOP" key.
a b
4.1- Learning mode:
- Switch the motor ON.
- Simultaneously press the "UP" and "DOWN" keys of a Hz transmitter.
The motor will run for 0,5 second in one direction, then in the other. The
transmitter now controls the motor in unstable mode, move to stage 4.2.
4.2- Checking the rotation direction:
Press the "UP" key of the transmitter:
a- If the motorized tube runs in the UP direction, move to next stage (4.3).
b- If the motorized tube runs in the DOWN direction, reverse the rotation direction by pressing the "Stop" key for at least 3 seconds. The
motor will conrm the reversal of the rotation direction by running for 0,5 second in one direction, then in the other direction. Move to the
stage 4.3.
4.3- Adjustement of the end-limits: memorizing the end points:
The end-limit adjustement can be done in two ways:
- First you can memorize the DOWN position (a) and then the UP position (b).
- First you can memorize the UP position (b) and then the DOWN position (a).
EN

<
≥
6.2- Validate the operation from the new transmitter you
want to program:
- Press the PROG key of the transmitter for about 1 second.
The motor will run for 0,5 second in one direction, then in
the other.
6.1- Open the memory of the receiver from the control
transmitter:
- Press the PROG key of the transmitter for about 3 seconds.
The motor will run for 0,5 second in one direction, then in
the other.
Programming a new (individual, group or main) control point:
6
Recording / controling / deleting intermediate position
7
Recording:
- Position the motor on the wanted
position.
- Press 5 seconds on the "STOP"
key. The motor will run for 0,5
second in one direction and then in
the other.
Deleting: Position the motor on the intermediate position. Press 5 seconds on the "STOP" key, the intermediate
position is deleted.
Controling:
- Press on the "STOP" key
for 0.5 s. the motor goes to
the intermediate position.
- For group controls, repeat operations 6.1 and 6.2 for each motor in the group.
- For main controls, repeat operations 6.1 and 6.2 for each motor in the installation.
- To delete an transmitter from the memory of a motor, perform operations 6.1 with a programmed transmitter, then
perform the operation 6.2 with the transmitter to be deleted.
4/5
1- Position the motor on the DOWN end limit
previously set in §4.3a with the "DOWN" key.
2- Press simultaneously for 5 seconds the "UP" and
"DOWN" keys, The motor will run for 0,5 second in
one direction and then in the other direction.
3- Adjust the new position with the "UP" and
"DOWN" keys.
4- Validate the new position by pressing 2 seconds the
"STOP" key. The motor will run for 0,5 second in one
direction and then in the other direction.
The new end limits setting is memorized.
8.2- Re-adjustement of DOWN end limits:
1- Position the motor on the UP end limit previously set
in §4.3b with the "UP" key.
2- Press simultaneously for 5 seconds the "UP" and
"DOWN" keys, The motor will run for 0,5 second in
one direction and then in the other direction.
3- Adjust the new position with the "UP" and "DOWN"
keys.
4- Validate the new position by pressing 2 seconds the
"STOP" key. The motor will run for 0,5 second in one
direction and then in the other direction.
The new end limits setting is memorized.
8.1- Re-adjustement of UP end limits:
Re-adjustement of end limits
8
EN

- This drive is maintenance-free.
- Press the ▲ button on the control point to raise the motorised product.
- Press the ▼ button on the control point to lower the motorised product.
- If the motorised product is moving, briey press the “STOP” button, the motorised product stop automatically.
- The motorised product is then stopped, briey press the “STOP” button, the motorised product moves to the
programmed intermediate position. (To modify or delete an intermediate position, see the section §7).
Tips and recommendations for use:
If the motorised product still does not work, contact a drive and home automation professional.
5/5
SIMU SAS, F-70103 GRAY as manufacturer hereby declares that the drive covered by these instructions when marked for input voltage 230V~50Hz
and used as intended according to these instructions, is in compliance with the essential requirements of the applicable European Directives and in
particular of the Machinery Directive 2006/42/EC, and the Radio Directive 2014/53/EU. The full text of the EU declaration of conformity is available at
www.simu.com. Emmanuel CARMIER, general director, GRAY, 12/2016.
9.1- Switch off the power supply to the motor for 2 seconds.
9.2- Switch the power to the motor back on for 7 seconds.
9.3- Switch off the power supply to the motor for 2 seconds.
9.4- Switch the power to the motor back on.
- If the motor is on the end limit position (up or down), the
motor will run briey on one direction and then in the
other, otherwise, the motor runs for 5 seconds in random
direction. The motor is now in the "cancelling" mode.
Cancelling programming and settings
9
Operation and maintenance
10
9.5- Then, validate the cancelling of the affected motor from the individual control:
If you switch off the power to several motors, they will all be in cancelling mode. That is why, you must
"eject" out of this mode all the motors that are not to be deleted by sending a command from their
individual control transmitter (UP or Down).
- Press the PROG key of the transmitter more than 7
seconds. Maintain the pressure until the motor will rst
run for 0,5 second in one direction and then the other,
and a few second later, it will run again in both direction.
The Hz02 motor is now as it was originally congured, and no transmitter and no settings is saved in its memory and is
ready for a new programming.
>
Problems Possible causes Solutions
The motorised product does not operate. The overheating protection on the drive has been activated. Wait for the drive to cool down.
EN
Other manuals for T3.5Hz02
1
This manual suits for next models
2
Table of contents
Other Simu Engine manuals

Simu
Simu T3.5 E Hz.02 DC User manual

Simu
Simu T5 CC Series User manual

Simu
Simu CENTRIS User manual

Simu
Simu T925/8 M User manual

Simu
Simu DMI6 Hz User manual

Simu
Simu DMI 5 Hz User manual

Simu
Simu T8S DMI User manual

Simu
Simu T5 E Hz User manual

Simu
Simu T3.5DC User manual

Simu
Simu SIMUBOX 220/12 TRI User manual