SIGMA TEK HGT 1051 User manual

HGT 1051
Handheld Operating Panel
Operating Manual
Date of creation: 23.02.2018
Version date: 17.12.2019
Article number: 01-245-1051-E

Publisher: SIGMATEK GmbH & Co KG
A-5112 Lamprechtshausen
Tel.: +43/6274/4321
Fax: +43/6274/4321-18
WWW.SIGMATEK-AUTOMATION.COM
Copyright © 2018
SIGMATEK GmbH & Co KG
Translation from German
All rights reserved. No part of this work may be reproduced, edited using an electronic system, duplicated or dis-
tributed in any form (print, photocopy, microfilm or in any other process) without the express permission.
We reserve the right to make changes in the content without notice. The SIGMATEK GmbH & Co KG is not responsi-
ble for technical or printing errors in the handbook and assumes no responsibility for damages that occur through
use of this handbook.

10.1" HANDHELD CONTROL PANEL HGT 1051
17.12.2019 Page 1
10.1" Handheld Control Panel HGT 1051
The HGT 1051 is an intelligent handheld control
panel used for programming and visualization of
automated processes. Process diagnostics, operat-
ing and monitoring functions are thereby simplified.
An emergency stop, key and confirmation switch
are implemented as a Safety application.
A touch screen serves as the input medium for
process data and parameters. The output is shown
on a 10.1" WXGA TFT color display.
With the LSE mask editor, graphics can be created
on the PC, then stored and displayed on the
handheld control panel.
The available interfaces can be used to exchange
process data or configure the handheld control panel. On the Flash card, the operating
system, application and application data are stored.

HGT 1051 10.1“ HANDHELD CONTROL PANEL
Page 2 17.12.2019
Contents
1Essential Components........................................................... 4
2Basic Safety Guidelines......................................................... 5
2.1 Symbols Used...............................................................................5
2.2 General Safety Guidelines...........................................................7
2.3 Designated Use.............................................................................8
2.4 Residual Risks ............................................................................11
2.5 Safety of the Machine or Equipment ........................................12
2.6 Conformity with EU Guidelines.................................................12
2.7 Functional Safety Standards.....................................................12
2.8 Safety-Relevant Parameters......................................................13
3Technical Data .......................................................................14
3.1 Performance Data.......................................................................14
3.2 Electrical Requirements.............................................................15
3.3 Terminal.......................................................................................16
3.4 Environmental Conditions.........................................................16
3.5 Display.........................................................................................17
3.6 Terminal Requirements..............................................................17
3.7 Miscellaneous .............................................................................17
4Mechanical Dimensions........................................................18
4.1 Wall Mount...................................................................................19
5Interface Connections...........................................................20

10.1" HANDHELD CONTROL PANEL HGT 1051
17.12.2019 Page 3
5.1 Rear Connectors.........................................................................20
5.2 Key Switch...................................................................................23
5.3 Confirmation Switch...................................................................24
5.4 Emergency Stop..........................................................................25
6Storage Media........................................................................26
7Wiring Guidelines..................................................................27
7.1 ESD Protection............................................................................27
7.2 USB Interface Connections .......................................................27
8Cleaning the Touch Screen..................................................28
9Recommended Cable Shielding...........................................29
9.1 Connection from the Control Cabinet to the HGT ...................29

HGT 1051 10.1“ HANDHELD CONTROL PANEL
Page 4 17.12.2019
1 Essential Components
•10.1" WXGA TFT color display with LED backlighting
•10.1“ projected capacitive touch screen
•Confirmation switch (mounted on the rear side), 2-channel configuration
•Key switch (mounted top-center), two channel wiring.
•Emergency stop switch (mounted top-center), two channel wiring.
•USB socket with cover
•M16 connector (90° swivel)
•Applicable Safety controls:
- SCP XXX

10.1" HANDHELD CONTROL PANEL HGT 1051
17.12.2019 Page 5
2 Basic Safety Guidelines
2.1 Symbols Used
For warning, danger messages and informational notes, the following symbols are used in
the operator documentation:
DANGER
DANGER
Identifies an immediate danger with high risk, which
can lead to immediate death or serious injury if not
avoided.
Indique un danger direct à haut risque d’un décès
immédiat ou des blessures graves si les consignes de
sécurité ne sont pas respectées.
WARNING
WARNING
Identifies a possible danger with a mid-level risk,
which can lead to death or (serious) injury if not
avoided.
Indique un danger possible d’un risque moyen de
décès ou de (graves) blessures si les consignes de
sécurité ne sont pas respectées.
CAUTION
CAUTION
Identifies a low risk danger, which can lead to injury or
property damage if not avoided.
Indique un danger avec un niveau de risque faible des
blessures légères ou des dommages matériels si les
consignes de sécurité ne sont pas respectées.
Danger for ESD-sensitive components
Les signes de danger pour les composants sensibles
aux décharges électrostatiques

HGT 1051 10.1“ HANDHELD CONTROL PANEL
Page 6 17.12.2019
This symbol identifies important or additional infor-
mation regarding the operation of the safety modules.
Ce symbole indique des informations importantes ou
supplémentaires concernant le fonctionnement des
modules de sécurité particuliers.
INFORMATION
Provides user tips, informs of special features and
identifies especially important information in the text.
Fournit des conseils d'utilisation, informe sur les fonc-
tions particulaires et souligne les informations particu-
lièrement importantes dans le texte.

10.1" HANDHELD CONTROL PANEL HGT 1051
17.12.2019 Page 7
2.2 General Safety Guidelines
According to the EU Guideline 2006/42/EG, the operating instructions are a
component of a product.
This manual must therefore be accessible in the vicinity of the machine,
since it contains important instructions.
The technical documentation should be included in the sale, rental or transfer
of the product.
Please read the corresponding data sheets, operating instructions and oper-
ator instructions thoroughly before handling Safety modules. SIGMATEK is
not liable for damages caused through non-compliance with these instruc-
tions or respective regulations.
The general and special safety instructions described in the following sec-
tions, as well as technical regulations, must therefore be observed.
Subject technical changes, which improve the performance of the devices.
The following documentation represents a series of product descriptions. It
does not guarantee properties under the warranty.
Regarding the requirements for Safety and health connected to the use of
machines, the manufacturer must perform a risk assessment in accordance
with machine guidelines 2006/42/EG before introducing a machine to the
market.

HGT 1051 10.1“ HANDHELD CONTROL PANEL
Page 8 17.12.2019
2.3 Designated Use
The Safety functions implemented in the Safety modules are designed for use with safety-
related applications in a PLC control and meet the required conditions for safe operation in
SIL 3 or SIL CL 3 according to EN 62061 and in compliance with PL e. Cat. 4 in accordance
with EN ISO 13849-1.
The instructions contained in this document must be followed.
Safety functions can only be powered by supplies that meet the require-
ments for PELV in compliance with EN60204.
For error-free operation, proper transport and storage are essential.
Installation, mounting, programming, initial start-up, operation, maintenance
and discarding of the Safety module can only be performed by qualified
personnel.
Qualified personnel in this context are people who have completed training
or have trained under supervision of qualified personnel and have been
authorized to operate and maintain safety-related equipment, systems and
facilities in compliance with the strict guidelines and standards of safety
technology. The applicable environmental conditions must be maintained.
Les instructions de cette documentation doivent être respectées.
Les composants de sécurité ne doivent être alimentés que par des alimenta-
tions conformes aux exigences PELV selon la norme EN60204.
Un transport et un stockage approprié sont essentiels au bon fonctionne-
ment.
L'installation, le montage, la programmation, la mise en service, l'exploita-
tion, la maintenance et la mise hors service des modules de sécurité ne
doivent être effectués que par du personnel qualifié.
En ce sens, les personnes qualifiées sont des personnes ayant acquis la
formation respective ou étant formées par un spécialiste pour superviser des
dispositifs, systèmes et systèmes de sécurité conformément aux directives
et normes de sécurité applicables. Les conditions environnementales appli-
cables doivent être respectées.
Table of contents
Other SIGMA TEK Control Panel manuals

SIGMA TEK
SIGMA TEK HGW 1033-3 User manual

SIGMA TEK
SIGMA TEK ETV 1591-H User manual

SIGMA TEK
SIGMA TEK HGT 835 User manual

SIGMA TEK
SIGMA TEK ETV 0833-3 User manual

SIGMA TEK
SIGMA TEK 1U619-001 User manual

SIGMA TEK
SIGMA TEK HBG 1011 User manual

SIGMA TEK
SIGMA TEK ETT 732 User manual

SIGMA TEK
SIGMA TEK HGT 1053 User manual

SIGMA TEK
SIGMA TEK ETV 0853-3 User manual

SIGMA TEK
SIGMA TEK HZS 774 User manual