SGM LEKTRA RSL200 User manual

RSL200
vibration level switch, with rigid and semi-flexible extension for bulk
solids and powders.
technical documentation EN Rev. M

Page 2 of 16 www.sgm-lektra.com
RSL200 - contents
CONTENTS
1-WARRANTY
2-PRODUCT
3-TECHNICAL SPECIFICATIONS
4-DIMENSIONS
5-INSTALLATION
6-ELECTRICAL CONNECTIONS
7-LOCAL OPERATOR INTERFACE (LOI)-VL601
8-PARAMETER PROGRAMMING
9-TESTING AND QUALITY CERTIFICATE
page 3
page 4
page 5
page 6
page 7
page 10
page 11
page 12
page 16

Page 3 of 16
www.sgm-lektra.eu
RSL200 - warranty
Products supplied by SGM LEKTRA are guaranteed for a period of 12 (twelve) months from delivery date according to
the conditions specified in our sale conditions document.
SGM LEKTRA can choose to repair or replace the Product.
If the Product is repaired it will maintain the original warranty terms, whereas if the Product is replaced it will have 12
(twelve) months of warranty.
The warranty will be null if the Client modifies, repair or uses the Products for other purposes than the normal conditions
foreseen by instructions or Contract.
In no circumstances shall SGM LEKTRA be liable for direct, indirect or consequential or other loss or damage whether
caused by negligence on the part of the company or its employees or otherwise howsoever arising out of defective goods
1-WARRANTY

Page 4 of 16 www.sgm-lektra.com
RSL200- product
2- 2- PRODUCT
1. Cover
2. VL601 (opt.)
3. Skintop M20
4. Process connection
5. Forks
6. Anti-condensate filter
2.1 IDENTIFICATION
Every instrument has an adhesive identification plate on which the main information about the meter is outlined.
The following image describes the information and data on the plate.
RSL200A0F1D
CV0081901422
2
3
1Mod.
P.S.
S.N.
85÷250Vac
1. Product code 3. Serial number2. Power supply
1
2
3
5
4
6

Page 5 of 16
www.sgm-lektra.eu
3-3- TECHNICAL SPECIFICATIONS
RSL200 - technical specifications
Casing material
PC/AL
Vibrating prong material
AISI316 (AISI304 for semi-flexible extension tube)
Protection rating
IP67/IP68 in process
Pressure
-1 ÷ +6bar
Ambient temperature
-20 to +60°C
Max. process temperature
150°C
Power supply
24Vdc ÷ 115Vac; 85÷230Vac
Max. input power
1.5W
Cable glands
M20x1.5
Electrical connection
Plug-in terminal blocks
Relay output
3A 230Vac
Trigger mode
min. or max. level
Trigger delay
0÷30s (programmable)
Programming
Via extractable VL601 module
Trigger sensitivity and delay
configurable via VL601
Thermal stability
1 typical minute
Display
LCD display on extractable VL601-SGM module Green LED: power on
Red LED: relay status (on with relay energized)
Certification
ATEX II 1/2D Ex ta/tb IIIC T150°C Da/Db (opt.)

Page 6 of 16 www.sgm-lektra.com
4-4- DIMENSIONS
RSL200 - dimensions
5.1 MECHANICAL DIMENSIONS
Ø95 130
132,5
1"½ G
155
20
353
Ø95
132,5
1"½ G
130
20
513
Ø95
132,5
1"½ G
20
Ø12
86 62155
45,5
20
155 205,5
20
130
20
L=....
L=....

Page 7 of 16
www.sgm-lektra.eu
RSL200 - installation
5-5- INSTALLATION
5.1 PRECAUTIONS FOR INSTALLATION
5.1.1 CORRECT INSTALLATION
Correct installation of RSL200 sensors to control a Max. level (“a” and “c”) and Min. level (b).
To avoid triggering problems, follow the instructions below:
- Install away from loading zones and keep a minimum distance of 300mm from the walls of the tank.
- When placing the order, select the option for the extension length, allowing the sensitive element to be
positioned at least 200 mm from the bottom of the tank.
Min. dist.
300mm
Min. dist.
200mm
“a” “b”
“c”
Maximum
level
Minimum
level

Page 8 of 16 www.sgm-lektra.com
RSL200 - installation
5.1.2 Incorrect installation
Incorrect installation of RSL200 sensors.
• do not install near loading zones (c); false alarm signals may be generated and the RSL200 sensors may be
damaged by the pouring in of the material.
• do not install at the centre of the tank loading point (d); the RSL200 sensors and/or ceiling of the tank may be
damaged and eventually break the RSL200 sensor, due to the elevated mechanical stress created in this point.
• do not install in points where accumulations of product may form (e); the RSL200 sensors might remain blocked
in the ‘product present’ position: false max. level alarm or, vice versa, failed min. level alarm signal.
“c” “d” “e”

Page 9 of 16
www.sgm-lektra.eu
RSL200 - installation
5.1.3 Semiflex Extension
Bent extension (h) (g)
The extension must be straightened (i) to prevent the sensitive element from touching the wall of the tank and
sending a false ‘product present’ signal: false max. level alarm or, vice versa, failed min. level alarm signal.
“g” “h” “i”

Page 10 of 16 www.sgm-lektra.com
RSL200 - electrical connections
NO
C
NC
+Vdc / L (Vac)
-Vdc / N (Vac)
24Vdc÷115Vac and
85÷230Vac RL
Plug-in terminal blocks for connection of
power supply
Power ON green LED: On and fixed
Plug-in terminal blocks for connection of
relay contacts
RL red LED indicates the status of the relay:
on, RL relay energized
Earth connection of connector
6-ELECTRICAL CONNECTION
6.1 CONNECTIONS
1) Before energizing this product, make sure all connections have been correctly made and that the mains voltage
corresponds to that on the rating plate.
2) Tighten the cable glands and cover to ensure a protection rating of IP67.
3) To prevent the infiltration of water or humidity, which may damage the level sensor, do not remove the caps
of unused cable glands.
6.2 INFILTRATIONS OF HUMIDITY
To avoid infiltrations of humidity inside the cover, we recommend:
- Using a cable with an external diameter of 6÷12mm for the electrical connections and fully tightening the M20
cable gland
- Fully tighten the cover
- Position the cable in such a way as to form a downward curve in the output of the M20 cable gland;
in this way condensation and/or rainwater will tend to drip from the bottom of the curve.
Table of contents